• Shopping Cart
    There are no items in your cart

BS EN 60966-1:1999

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Radio frequency and coaxial cable assemblies Generic specification. General requirements and test methods

Available format(s)

Hardcopy , PDF

Superseded date

04-26-2019

Superseded by

BS EN IEC 60966-1:2019

Language(s)

English

Published date

10-15-1999

US$330.79
Excluding Tax where applicable

1 Scope
2 Normative References
3 Definitions
4 Design and Manufacturing Requirements
      4.1 Cable design and construction
      4.2 Connector design and construction
      4.3 Outline and interface dimensions
5 Workmanship, marking and packaging
      5.1 Workmanship
      5.2 Marking
      5.3 End caps
      5.4 Packaging and labelling
6 Quality Assessment
7 Test Methods - General
      7.1 Standard atmospheric conditions for testing
      7.2 Visual inspection
      7.3 Dimensions inspection
8 Electrical Tests
      8.1 Reflection properties
      8.2 Uniformity of impedance
      8.3 Insertion loss
      8.4 Insertion loss stability
      8.5 Propagation time
      8.6 Stability of electrical length
      8.7 Phase difference
      8.8 Phase variation with temperature
      8.9 Screening effectiveness
      8.10 Voltage proof
      8.11 Insulation resistance
      8.12 Inner and outer Conductor continuity
      8.13 Void
      8.14 Power rating
      8.15 Intermodulation level measurement
9 Mechanical Robustness Tests
      9.1 Tensile
      9.2 Flexure
      9.3 Flexing endurance
      9.4 Cable assembly crushing
      9.5 Torque
      9.6 Multiple bending
      9.7 Abrasion test of cable assembly
      9.8 Vibrations, shocks and impact
      9.9 Mechanical endurance
10 Environmental Tests
      10.1 Recommended severities
      10.2 Vibration, bumps and shock
      10.3 Climatic sequence
      10.4 Damp heat, steady state
      10.5 Rapid change of temperature
      10.6 Solvents and contaminating fluids
      10.7 Water immersion
      10.8 Salt mist and sulphur dioxide tests
      10.9 Dust tests
      10.10 Flammability
11 Specialized Test Methods
12 Test Schedules
Annex A (normative) Test Methods for Insertion Loss
                    Determination
      A.1 - Purpose
      A.2 - Test Methods
            A.2.1 - Test Method 1
            A.2.2 - Test Method 2
            A.2.3 - Test Method 3
      A.3 - Correction for Characteristic Impedance
            Differences
Annex B (informative) Measuring Methods for Propagation Time
      B.1 - Resonance Method for Propagation Time Measurement
      B.2 - Time Domain Method for Propagation Time Measurement
Annex C (informative) Measurement Method for Screening
                      Effectiveness
      C.1 - Introduction
      C.2 - Test Method
Annex D (informative) Recommended Severities for Environmental
                      Tests
      D.1 - Introduction to the Relationship between
            Environmental Conditions and Test Severities
            D.1.1 - General
            D.1.2 - Environmental Conditions
            D.1.3 - Environmental Testing
      D.2 - Severities for Environmental Testing
            D.2.1 - Vibration
            D.2.2 - Bump
            D.2.3 - Shock
            D.2.4 - Climatic Sequence
            D.2.5 - Damp Heat, Steady State
            D.2.6 - Rapid Change of Temperature
            D.2.7 - Salt Mist
            D.2.8 - Sulphur Dioxide Test
            D.2.9 - Dust Test
Annex E (normative) Quality Assessment
      E.1 - Object
      E.2 - General
            E.2.1 - Related Documents
            E.2.2 - Standards and Preferred Values
            E.2.3 - Marking of the Cable Assembly and
                    Packaging
            E.2.4 - Terminology
      E.3 - Quality Assessment Procedures
            E.3.1 - Procedures for Qualification Approval
            E.3.2 - Procedures for Capability Approval
            E.3.3 - Quality Conformance Inspection
      E.4 - Capability Manual and Approval
            E.4.1 - Responsibilities
            E.4.2 - Contents of the Capability Manual
            E.4.3 - Criteria for Capability Limits
Annex ZA (normative) Normative References to International
                     Publications with their corresponding
                     European Publications
Table D.1 - Relationship between Displacement and Acceleration
Table D.2 - Relationship between Peak Acceleration and Velocity
            Change
Table E.1 - Example of Capability Limits for Cable Assemblies
Table E.2 - Example of Capability Limits for Flexible Cables
Table E.3 - Example of Capability Limits for Connectors
Table E.4 - Example of Flow Chart
Figure 1 - Bending Test: U Shape Assembly
Figure 2 - Bending Test: Straight Assembly
Figure 3 - Twisting Test: U Shape Assembly
Figure 4 - Fixture for Cable Assembly Flexure Test
Figure 5 - Apparatus for Cable Assembly Flexing Endurance Test
Figure 6 - Fixture for Cable Crushing Test
Figure 7 - Multiple Bending Test
Figure 8 - Dust Measuring Device
Figure A.1 - Circuit for the Determination of Insertion Loss
Figure A.2 - Circuit for the Determination of Insertion Loss
Figure A.3 - Alternative Circuit for the Determination of
             Insertion Loss
Figure A.4 - Double-Pass Circuit for the Determination of
             Insertion Loss
Figure B.1 - Arrangement of Test Equipment
Figure C.1 - Line Injection Test Circuit for Coaxial Cable
             Assemblies
Figure C.2 - Schematic Transfer Functions of a Coaxial Cable
             Assembly
Figure C.3 - Complete Installation for Practical Screening
             Effectiveness Measurements
Figure D.1 - Description of Action Needed for the Preparation
             of the Environmental Test Specification

Defines the criteria for radio frequency coaxial cable assemblies which operate in the transverse electromagnetic mode (TEM) and identifies requirements for testing mechanical, electrical and environmental properties of radio frequency coaxial cable assemblies made up of connectors and cables. Other requirements which relate to particular families of cable assemblies are provided in the relevant specifications.

Committee
EPL/46
DevelopmentNote
Also numbered IEC 60966-1 and QC 140000 Supersedes 97/231854 DC (05/2005) Reviewed and confirmed by BSI, October 2005. (10/2005)
DocumentType
Standard
Pages
44
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
I.S. EN 60966-1:1993 Identical
DIN EN 60966-1 : 1999 Identical
NBN EN 60966-1 : 2000 Identical
NF EN 60966-1 : 1999 Identical
EN 60966-1:1999 Identical
SN EN 60966-1 : 1999 Identical
IEC 60966-1:1999 Identical

IEC 60068-2-68:1994 Environmental testing - Part 2-68: Tests - Test L: Dust and sand
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
HD 350.1 : 200S1 GENERAL PURPOSE RIGID COAXIAL TRANSMISSION LINES AND THEIR ASSOCIATED FLANGE CONNECTORS - GENERAL REQUIREMENTS AND MEASURING METHODS
IEC 60332-1:1993 Tests on electric cables under fire conditions - Part 1: Test on a single vertical insulated wire or cable
IEC 60068-2-11:1981 Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist
EN 61169-1:2013/AC:2016-02 RADIO-FREQUENCY CONNECTORS - PART 1: GENERIC SPECIFICATION - GENERAL REQUIREMENTS AND MEASURING METHODS (IEC 61169-1:2013)
EN ISO 9002:1994/AC:1997 QUALITY SYSTEMS - SPECIFICATION FOR PRODUCTION AND INSTALLATION
IEC 60339-1:1971 General purpose rigid coaxial transmission lines and their associated flange connectors. Part 1: General requirements and measuring methods
HD 323.2.14 : 200S2 BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST N: OF TEMPERATURE
ISO 9002:1994 Quality systems — Model for quality assurance in production, installation and servicing
IEC 61169-1:2013 Radio frequency connectors - Part 1: Generic specification - General requirements and measuring methods
EN 60068-2-27:2009 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
HD 323.2.3 : 200S2 BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST CA - DAMP HEAT, STEADY STATE
IEC 60068-2-3:1969 Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
EN 60068-2-68:1996 Environmental testing - Part 2: Tests - Test L: Dust and sand
ISO 9001:2015 Quality management systems — Requirements
IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
EN 60068-2-29:1993 Environmental testing - Part 2: Tests - Test Eb and guidance: Bump
EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
ISO 9000:2015 Quality management systems — Fundamentals and vocabulary
IEC 60068-2-29:1987 Environmental testing. Part 2: Tests. Test Eb and guidance: Bump
IEC 61196-1:2005 Coaxial communication cables - Part 1: Generic specification - General, definitions and requirements
EN 60068-2-11:1999 Environmental testing - Part 2: Tests - Test Ka: Salt mist
IEC 60339-2:1996 General purpose rigid coaxial transmission lines and their associated flange connectors - Part 2: Detail specifications
HD 350.2 : 200S1 GENERAL PURPOSE RIGID COAXIAL TRANSMISSION LINES AND THEIR ASSOCIATED FLANGE CONNECTORS - DETAIL SPECIFICATIONS
IEC 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
EN ISO 9000:2015 Quality management systems - Fundamentals and vocabulary (ISO 9000:2015)
IEC 61726:2015 Cable assemblies, cables, connectors and passive microwave components - Screening attenuation measurement by the reverberation chamber method

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.