BS EN 60966-1:1999
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Radio frequency and coaxial cable assemblies Generic specification. General requirements and test methods
Hardcopy , PDF
04-26-2019
English
10-15-1999
1 Scope
2 Normative References
3 Definitions
4 Design and Manufacturing Requirements
4.1 Cable design and construction
4.2 Connector design and construction
4.3 Outline and interface dimensions
5 Workmanship, marking and packaging
5.1 Workmanship
5.2 Marking
5.3 End caps
5.4 Packaging and labelling
6 Quality Assessment
7 Test Methods - General
7.1 Standard atmospheric conditions for testing
7.2 Visual inspection
7.3 Dimensions inspection
8 Electrical Tests
8.1 Reflection properties
8.2 Uniformity of impedance
8.3 Insertion loss
8.4 Insertion loss stability
8.5 Propagation time
8.6 Stability of electrical length
8.7 Phase difference
8.8 Phase variation with temperature
8.9 Screening effectiveness
8.10 Voltage proof
8.11 Insulation resistance
8.12 Inner and outer Conductor continuity
8.13 Void
8.14 Power rating
8.15 Intermodulation level measurement
9 Mechanical Robustness Tests
9.1 Tensile
9.2 Flexure
9.3 Flexing endurance
9.4 Cable assembly crushing
9.5 Torque
9.6 Multiple bending
9.7 Abrasion test of cable assembly
9.8 Vibrations, shocks and impact
9.9 Mechanical endurance
10 Environmental Tests
10.1 Recommended severities
10.2 Vibration, bumps and shock
10.3 Climatic sequence
10.4 Damp heat, steady state
10.5 Rapid change of temperature
10.6 Solvents and contaminating fluids
10.7 Water immersion
10.8 Salt mist and sulphur dioxide tests
10.9 Dust tests
10.10 Flammability
11 Specialized Test Methods
12 Test Schedules
Annex A (normative) Test Methods for Insertion Loss
Determination
A.1 - Purpose
A.2 - Test Methods
A.2.1 - Test Method 1
A.2.2 - Test Method 2
A.2.3 - Test Method 3
A.3 - Correction for Characteristic Impedance
Differences
Annex B (informative) Measuring Methods for Propagation Time
B.1 - Resonance Method for Propagation Time Measurement
B.2 - Time Domain Method for Propagation Time Measurement
Annex C (informative) Measurement Method for Screening
Effectiveness
C.1 - Introduction
C.2 - Test Method
Annex D (informative) Recommended Severities for Environmental
Tests
D.1 - Introduction to the Relationship between
Environmental Conditions and Test Severities
D.1.1 - General
D.1.2 - Environmental Conditions
D.1.3 - Environmental Testing
D.2 - Severities for Environmental Testing
D.2.1 - Vibration
D.2.2 - Bump
D.2.3 - Shock
D.2.4 - Climatic Sequence
D.2.5 - Damp Heat, Steady State
D.2.6 - Rapid Change of Temperature
D.2.7 - Salt Mist
D.2.8 - Sulphur Dioxide Test
D.2.9 - Dust Test
Annex E (normative) Quality Assessment
E.1 - Object
E.2 - General
E.2.1 - Related Documents
E.2.2 - Standards and Preferred Values
E.2.3 - Marking of the Cable Assembly and
Packaging
E.2.4 - Terminology
E.3 - Quality Assessment Procedures
E.3.1 - Procedures for Qualification Approval
E.3.2 - Procedures for Capability Approval
E.3.3 - Quality Conformance Inspection
E.4 - Capability Manual and Approval
E.4.1 - Responsibilities
E.4.2 - Contents of the Capability Manual
E.4.3 - Criteria for Capability Limits
Annex ZA (normative) Normative References to International
Publications with their corresponding
European Publications
Table D.1 - Relationship between Displacement and Acceleration
Table D.2 - Relationship between Peak Acceleration and Velocity
Change
Table E.1 - Example of Capability Limits for Cable Assemblies
Table E.2 - Example of Capability Limits for Flexible Cables
Table E.3 - Example of Capability Limits for Connectors
Table E.4 - Example of Flow Chart
Figure 1 - Bending Test: U Shape Assembly
Figure 2 - Bending Test: Straight Assembly
Figure 3 - Twisting Test: U Shape Assembly
Figure 4 - Fixture for Cable Assembly Flexure Test
Figure 5 - Apparatus for Cable Assembly Flexing Endurance Test
Figure 6 - Fixture for Cable Crushing Test
Figure 7 - Multiple Bending Test
Figure 8 - Dust Measuring Device
Figure A.1 - Circuit for the Determination of Insertion Loss
Figure A.2 - Circuit for the Determination of Insertion Loss
Figure A.3 - Alternative Circuit for the Determination of
Insertion Loss
Figure A.4 - Double-Pass Circuit for the Determination of
Insertion Loss
Figure B.1 - Arrangement of Test Equipment
Figure C.1 - Line Injection Test Circuit for Coaxial Cable
Assemblies
Figure C.2 - Schematic Transfer Functions of a Coaxial Cable
Assembly
Figure C.3 - Complete Installation for Practical Screening
Effectiveness Measurements
Figure D.1 - Description of Action Needed for the Preparation
of the Environmental Test Specification
Defines the criteria for radio frequency coaxial cable assemblies which operate in the transverse electromagnetic mode (TEM) and identifies requirements for testing mechanical, electrical and environmental properties of radio frequency coaxial cable assemblies made up of connectors and cables. Other requirements which relate to particular families of cable assemblies are provided in the relevant specifications.
Committee |
EPL/46
|
DevelopmentNote |
Also numbered IEC 60966-1 and QC 140000 Supersedes 97/231854 DC (05/2005) Reviewed and confirmed by BSI, October 2005. (10/2005)
|
DocumentType |
Standard
|
Pages |
44
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
I.S. EN 60966-1:1993 | Identical |
DIN EN 60966-1 : 1999 | Identical |
NBN EN 60966-1 : 2000 | Identical |
NF EN 60966-1 : 1999 | Identical |
EN 60966-1:1999 | Identical |
SN EN 60966-1 : 1999 | Identical |
IEC 60966-1:1999 | Identical |
IEC 60068-2-68:1994 | Environmental testing - Part 2-68: Tests - Test L: Dust and sand |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
HD 350.1 : 200S1 | GENERAL PURPOSE RIGID COAXIAL TRANSMISSION LINES AND THEIR ASSOCIATED FLANGE CONNECTORS - GENERAL REQUIREMENTS AND MEASURING METHODS |
IEC 60332-1:1993 | Tests on electric cables under fire conditions - Part 1: Test on a single vertical insulated wire or cable |
IEC 60068-2-11:1981 | Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist |
EN 61169-1:2013/AC:2016-02 | RADIO-FREQUENCY CONNECTORS - PART 1: GENERIC SPECIFICATION - GENERAL REQUIREMENTS AND MEASURING METHODS (IEC 61169-1:2013) |
EN ISO 9002:1994/AC:1997 | QUALITY SYSTEMS - SPECIFICATION FOR PRODUCTION AND INSTALLATION |
IEC 60339-1:1971 | General purpose rigid coaxial transmission lines and their associated flange connectors. Part 1: General requirements and measuring methods |
HD 323.2.14 : 200S2 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST N: OF TEMPERATURE |
ISO 9002:1994 | Quality systems — Model for quality assurance in production, installation and servicing |
IEC 61169-1:2013 | Radio frequency connectors - Part 1: Generic specification - General requirements and measuring methods |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
HD 323.2.3 : 200S2 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST CA - DAMP HEAT, STEADY STATE |
IEC 60068-2-3:1969 | Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
EN 60068-2-68:1996 | Environmental testing - Part 2: Tests - Test L: Dust and sand |
ISO 9001:2015 | Quality management systems — Requirements |
IEC 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
EN 60068-2-29:1993 | Environmental testing - Part 2: Tests - Test Eb and guidance: Bump |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
ISO 9000:2015 | Quality management systems — Fundamentals and vocabulary |
IEC 60068-2-29:1987 | Environmental testing. Part 2: Tests. Test Eb and guidance: Bump |
IEC 61196-1:2005 | Coaxial communication cables - Part 1: Generic specification - General, definitions and requirements |
EN 60068-2-11:1999 | Environmental testing - Part 2: Tests - Test Ka: Salt mist |
IEC 60339-2:1996 | General purpose rigid coaxial transmission lines and their associated flange connectors - Part 2: Detail specifications |
HD 350.2 : 200S1 | GENERAL PURPOSE RIGID COAXIAL TRANSMISSION LINES AND THEIR ASSOCIATED FLANGE CONNECTORS - DETAIL SPECIFICATIONS |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
EN ISO 9000:2015 | Quality management systems - Fundamentals and vocabulary (ISO 9000:2015) |
IEC 61726:2015 | Cable assemblies, cables, connectors and passive microwave components - Screening attenuation measurement by the reverberation chamber method |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.