BS EN 60885-3:2015
Current
The latest, up-to-date edition.
Electrical test methods for electric cables Test methods for partial discharge measurements on lengths of extruded power cables
Hardcopy , PDF
English
06-30-2015
FOREWORD
1 Scope
2 Normative references
3 Terms, definitions and symbols
4 Overview
5 Partial discharge tests
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Describes the test methods for partial discharge (PD) measurements on lengths of extruded power cable, but does not include measurements made on installed cable systems.
Committee |
GEL/20/16
|
DevelopmentNote |
Supersedes 02/210392 DC (11/2003) 2003 Edition remains active & will be withdrawn on 14/05/2018. Supersedes 11/30257861 DC. (06/2015)
|
DocumentType |
Standard
|
Pages |
28
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of IEC60885 specifies the test methods for partial discharge (PD) measurements on lengths of extruded power cable, but does not include measurements made on installed cable systems. Reference is made to IEC60270 which gives the techniques and considerations applicable to partial discharge measurements in general.
Standards | Relationship |
UNE-EN 60885-3:2015 | Identical |
IEC 60885-3:2015 RLV | Identical |
I.S. EN 60885-3:2015 | Identical |
SN EN 60885-3 : 2003 | Identical |
EN 60885-3:2015 | Identical |
DIN EN 60885-3 : 2015 | Identical |
NF EN 60885-3 : 2015 | Identical |
NBN EN 60885-3 : 2015 | Identical |
IEC 60885-3:2015 | Identical |
07/30143023 DC : DRAFT MAR 2007 | BS 7835 - ELECTRIC CABLES - ARMOURED CABLES WITH THERMOSETTING INSULATION FOR RATED VOLTAGES FROM 3.8/6.6 KV TO 19/33 KV HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - REQUIREMENTS AND TEST METHODS |
06/30143016 DC : DRAFT SEP 2006 | BS 6622 - SPECIFICATION FOR CABLES WITH THERMOSETTING INSULATION FOR RATED VOLTAGES FROM 3.8/6.6 KV TO 19/33 KV |
BS 6622:2007 | Electric cables. Armoured cables with thermosetting insulation for rated voltages from 3.8/6.6 kV to 19/33 kV. Requirements and test methods |
BS 7912(2012) : 2012 | POWER CABLES WITH XLPE INSULATION AND METAL SHEATH, AND THEIR ACCESSORIES, FOR RATED VOLTAGES FROM 66 KV (U[M] = 72.5 KV) TO 132 KV (U[M] = 145 KV) |
BS 7835:2007 | Electric cables. Armoured cables with thermosetting insulation for rated voltages from 3.8/6.6 kV to 19/33 kV having low emission of smoke and corrosive gases when affected by fire. Requirements and test methods |
12/30244367 DC : 0 | BS 7912 - POWER CABLES WITH XLPE INSULATION AND METAL SHEATH, AND THEIR ACCESSORIES, FOR RATED VOLTAGES FROM 66 KV (U[M] = 72.5 KV) TO 132 KV (U[M] = 145 KV) |
BS 7870-2:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Methods of test |
11/30214057 DC : 0 | BS 7870-2 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 2: METHODS OF TEST |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
EN 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
EN 60270:2001/A1:2016 | HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015) |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.