BS EN 60728-4:2008
Current
The latest, up-to-date edition.
Cable networks for television signals, sound signals and interactive services Passive wideband equipment for coaxial cable networks
Hardcopy , PDF
English
06-30-2008
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions, symbols and abbreviations
3.1 Terms and definitions
3.2 Symbols
3.3 Abbreviations
4 Methods of measurement
4.1 Attenuation
4.1.1 Test equipment
4.1.2 Measurement procedure
4.1.3 Presentation of the results
4.2 Isolation
4.2.1 Definition
4.2.2 Test equipment
4.2.3 Measurement procedure
4.2.4 Presentation of the results
4.3 Through-loss
4.3.1 Definition
4.3.2 Test equipment
4.3.3 Measurement procedure
4.3.4 Presentation of the results
4.4 Group delay variation
4.4.1 Definition
4.4.2 Test equipment
4.4.3 Method of measurement
4.4.4 Presentation of the result
4.5 Amplitude frequency response
4.6 Return loss
4.7 Hum modulation of carrier
4.7.1 Definition
4.7.2 Description of the method of measurement
4.7.3 Measuring procedure
4.7.4 Calculating the hum-modulation ratio
4.7.5 Presentation of the results
4.8 Two-carrier intermodulation measurements for second- and
third-order products
5 Performance requirements and recommendations
5.1 General performance requirements and recommendations
5.1.1 Safety
5.1.2 Electromagnetic compatibility (EMC)
5.1.3 Environmental
5.1.4 Marking
5.1.5 Impedance
5.1.6 Degradation of performance caused by overvoltages
5.2 Performance requirements and recommendations for receiver lead
5.3 Performance requirements and recommendations for system outlets
5.3.1 Safety
5.3.2 Quality grading
5.3.3 Mechanical requirements
5.3.4 Electrical parameters and requirements
5.4 Performance requirements and recommendations for splitters and
taps
5.4.1 Description
5.4.2 Mechanical requirements for connectors
5.4.3 Electrical parameters and requirements
5.5 Performance requirements and recommendations for all other
passive equipment
5.5.1 Description
5.5.2 Mechanical requirements for connectors
5.5.3 Electrical parameters and requirements
Bibliography
Annex A (informative) - Measurement errors which occur due to
mismatched equipment
Annex B (informative) - Differences in some countries
Annex ZA (normative) - Normative references to international
publications with their corresponding European publications
Annex ZB (normative) - Special national conditions
Annex ZC (informative) - A-deviations
Applies to system outlets, splitters and taps, passive single or multiple port equipment comprising filters, attenuators, equalizers, galvanic isolators, power injectors, cable splices, terminating resistors and transfer points, but excluding coaxial cables and receiver leads.
Committee |
EPL/100
|
DevelopmentNote |
Supersedes BS EN 50083-4 & 06/30150081 DC. (07/2008)
|
DocumentType |
Standard
|
Pages |
38
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
IEC 60728-4:2007 applies to system outlets, splitters and taps, passive single or multiple port equipment comprising filters, attenuators, equalizers, galvanic isolators, power injectors, cable splices, terminating resistors and transfer points, but excluding coaxial cables and receiver leads. This standard:
- covers the frequency range 5 MHz to 3 000 MHz;
- identifies performance requirements for certain parameters;
- lays down data publication requirements for certain parameters;
- stipulates methods of measurements;
- introduces minimum requirements defining quality grades. This third edition cancels and replaces the second edition published in 2000, of which it constitutes a technical revision. It includes the following significant technical changes: Subclause 3.1 includes several new or modified definitions. Clause 4 includes added test methods for attenuation, isolation, through-loss, group delay variation, amplitude frequency response and two carrier intermodulation measurements for second- and third-order products. Clause 5 includes updated and new performance requirements.
Standards | Relationship |
IEC 60728-4:2007 | Identical |
EN 60728-4:2008 | Identical |
IEC 60077-3:2001 | Identical |
EN 61000-6-1:2007 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments |
EN 60966-2-4:2016 | Radio Frequency and coaxial cable assemblies - Part 2-4: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 3 000 MHz, IEC 61169-2 connectors |
IEC 60966-2-6:2016 | Radio frequency and coaxial cable assemblies - Part 2-6: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 3 000 MHz, IEC 61169-24 connectors |
EN 60966-2-6:2017 | Radio frequency and coaxial cable assemblies - Part 2-6: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 3 000 MHz, IEC 61169-24 connectors |
IEC 60966-1:1999 | Radio frequency and coaxial cable assemblies - Part 1: Generic specification - General requirements and test methods |
EN 61169-1:2013/AC:2016-02 | RADIO-FREQUENCY CONNECTORS - PART 1: GENERIC SPECIFICATION - GENERAL REQUIREMENTS AND MEASURING METHODS (IEC 61169-1:2013) |
IEC 61169-24:2009 | Radio-frequency connectors - Part 24: Sectional specification - Radio frequency coaxial connectors with screw coupling, typically for use in 75 Ω cable networks (type F) |
EN 60966-1:1999 | Radio frequency and coaxial cable assemblies - Part 1: Generic specification - General requirements and test methods |
IEC 61169-1:2013 | Radio frequency connectors - Part 1: Generic specification - General requirements and measuring methods |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60966-2-5:2016 | Radio frequency and coaxial cable assemblies - Part 2-5: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 1 000 MHz, IEC 61169-2 connectors |
IEC 60966-2-4:2016 | Radio frequency and coaxial cable assemblies - Part 2-4: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 3 000 MHz, IEC 61169-2 connectors |
IEC 61000-6-1:2016 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments |
EN 60966-2-5:2017 | Radio frequency and coaxial cable assemblies - Part 2-5: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 1 000 MHz, IEC 61169-2 connectors |
EN 61169-2:2007 | Radio-frequency connectors - Part 2: Sectional specification - Radio frequency coaxial connectors of type 9,52 |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 60050-581:2008 | International Electrotechnical Vocabulary (IEV) - Part 581: Electromechanical components for electronic equipment |
IEC 60050-723:1997 | International Electrotechnical Vocabulary (IEV) - Part 723: Broadcasting: Sound, television, data |
IEC 61169-2:2007 | Radio-frenquency connectors - Part 2: Sectional specification - Radio frequency coaxial connectors of type 9,52 |
EN 61169-24:2009 | Radio-frequency connectors - Part 24: Sectional specification - Radio frequency coaxial connectors with screw coupling, typically for use in 75 ohm cable networks (type F) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.