BS EN 60664-5:2003
Current
The latest, up-to-date edition.
Insulation coordination for equipment within low-voltage systems A comprehensive method for determining clearances and creepage distances equal to or less than 2 mm
Hardcopy , PDF
English
02-16-2004
INTRODUCTION
1 Scope and object
2 Normative references
3 Terms and definitions
4 Fundamentals of clearance and creepage distance
dimensioning
4.1 Introductory remark
4.2 Basic principles
4.3 Voltages and voltage ratings
4.4 Frequency
4.5 Time under voltage stress
4.6 Pollution
4.7 Information supplied with the equipment
4.8 Insulating material
5 Requirements and dimensioning procedures
5.1 General
5.2 Dimensioning of clearances
5.3 Dimensioning of creepage distances
5.4 Requirements for design of solid insulation
6 Tests and measurements
6.1 Tests
6.2 Measurement of creepage distances and clearances
Annex A (informative) - Dimensioning to maintain minimum
insulation resistance
Annex B (normative) - Water adsorption test
Annex C (informative) - Dimensioning diagrams
Annex D (informative) - Withstand voltage test for creepage
distance under humid conditions
Annex ZA (normative) - Normative references to international
publications with their corresponding
European publications
Bibliography
Describes the dimensioning of clearances and creepage distances for spacings equal to or less than 2 mm for printed wiring board and equivalent constructions, where the clearance and the creepage distance are identical and are along the surface of solid insulation.
Committee |
GEL/109
|
DevelopmentNote |
To be read in conjunction with BS EN 60664-1. Supersedes 06/30151798 DC. (12/2007)
|
DocumentType |
Standard
|
Pages |
42
|
PublisherName |
British Standards Institution
|
Status |
Current
|
SupersededBy | |
Supersedes |
Specifies the dimensioning of clearances and creepage distances for spacings equal to or less than 2 mm for printed wiring board and equivalent constructions, where the clearance and the creepage distance are identical and are along the surface of solid insulation, such as the paths described in example 1, example 5 and example 11 of 4.2 of Part 1. The dimensioning is more precise than that provided by Part 1 (i.e IEC 60664-1). This standard can only be used as an entirety. It is not permitted to select one or more clauses from this standard and to use them in place of the corresponding clauses of Part 1. When this standard is applied to the dimensioning of clearances and creepage distances, all clauses shall be used in place of the corresponding clauses given in Part 1. For clearances and creepage distances larger than 2 mm and for solid insulation in general, Part 1 applies. This standard is based on the following criteria for dimensioning: - minimum clearances independent of the micro-environment (see Table 2); - minimum creepage distances for pollution degrees 1, 2 and 3 to avoid failure due to tracking (see Table 4); - minimum creepage distances to avoid flashover across the insulating surface (see Table 5). A test method is specified for allocating unclassified insulating material to the relevant water adsorption group. Has the status of a basic safety publication in accordance with IEC Guide 104.
Standards | Relationship |
DIN EN 60664-5 : 2008 | Identical |
UNE-EN 60664-5:2008 | Identical |
EN 60664-5:2007 | Identical |
SN EN 60664-5 : 2003 | Identical |
I.S. EN 60664-5:2007 | Identical |
NF EN 60664-5 : 2008 | Identical |
IEC 60664-5:2007 | Identical |
NBN EN 60664-5 : 2008 | Identical |
BS 1363-1:2016+A1:2018 | 13 A plugs, socket-outlets, adaptors and connection units Specification for rewirable and non-rewirable 13 A fused plugs |
15/30297234 DC : 0 | BS 1363-2 - 13 A PLUGS, SOCKET-OUTLETS, ADAPTORS AND CONNECTION UNITS - PART 2: SPECIFICATION FOR 13 A SWITCHED AND UNSWITCHED SOCKET-OUTLETS |
15/30297238 DC : 0 | BS 1363-4 - 13 A PLUGS, SOCKET-OUTLETS, ADAPTORS AND CONNECTION UNITS - PART 4: SPECIFICATION FOR 13 A FUSED CONNECTION UNITS SWITCHED AND UNSWITCHED |
15/30297236 DC : 0 | BS 1363-3 - 13 A PLUGS, SOCKET-OUTLETS, ADAPTORS AND CONNECTION UNITS - PART 3: SPECIFICATION FOR ADAPTORS |
15/30297232 DC : 0 | BS 1363-1 - 13 A PLUGS, SOCKET-OUTLETS, ADAPTORS AND CONNECTION UNITS - PART 1: SPECIFICATION FOR REWIRABLE AND NON-REWIRABLE 13 A FUSED PLUGS |
IEC 60721-3-9:1993 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 9: Microclimates inside products |
EN 60721-3-9:1993/A1:1995 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 3: CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - SECTION 9: MICROCLIMATES INSIDE PRODUCTS |
IEC 60364-5-51:2005 | Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules |
IEC 60721-3-7:1995+AMD1:1996 CSV | Classification of environmental conditions - Part 3-7: Classification of groups of environmental parameters and their severities - Portable and non-stationary use |
EN 60721-3-7:1995/A1:1997 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 3: CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - SECTION 7: PORTABLE AND NON-STATIONARY USE |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV | Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 60721-3-3 : 95 AMD 2 97 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - STATIONARY USE AT WEATHER-PROTECTED LOCATIONS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.