BS EN 60601-2-36:2015
Current
The latest, up-to-date edition.
Medical electrical equipment Particular requirements for the basic safety and essential performance of equipment for extracorporeally induced lithotripsy
Hardcopy , PDF
English
06-30-2015
Committee |
CH/62/4
|
DevelopmentNote |
Supersedes 93/503810 DC. (11/2005) 1997 Edition remains active & will be withdrawn on 22/05/2018. Supersedes 12/30253196 DC. Supersedes BS 5724-2.36(1997) which remains active & will be withdrawn on 22/05/2018. (06/2015)
|
DocumentType |
Standard
|
Pages |
28
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
IEC 60601-2-36:2014 applies to basic safety and essential performance of equipment for extracorporeally induced lithotripsy including equipment for other medical applications of therapeutic extracorporeally induced focused pressure pulses. The applicability of this particular standard is limited to components directly involved in the lithotripsy treatment, such as, but not limited to, the generator of the pressure pulse, patient support device, and their interactions with imaging and monitoring devices. Other devices, such as patient treatment planning computers, X-ray and ultrasonic devices, are excluded from this standard, because they are treated in other applicable IEC standards. This particular standard does not apply to ultrasound physiotherapy equipment intended to be used for physiotherapy; abd to ultrasound equipment intended to be used for high intensity therapeutic ultrasound (HITU) and other therapy equipment as described in Annex AA. This second edition cancels and replaces the first edition of IEC 60601-2-36 published in 1997. This edition constitutes a technical revision to align structurally with IEC 60601-1:2005 and its Amendment1:2012.
Standards | Relationship |
I.S. EN 60601-2-36:2015 | Identical |
DIN EN 60601-2-36 : 2015 | Identical |
EN 60601-2-36:2015 | Identical |
IEC 60601-2-36:2014 | Identical |
SN EN 60601-2-36 : 1997 | Identical |
UNE-EN 60601-2-36:1998 | Identical |
EN 10002-1 : 2001 | METALLIC MATERIALS - TENSILE TESTING - PART 1: METHOD OF TEST AT AMBIENT TEMPERATURE |
IEC 60601-2-5:2009 | Medical electrical equipment - Part 2-5: Particular requirements for the basic safety and essential performance of ultrasonic physiotherapy equipment |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
IEC 61689:2013 | Ultrasonics - Physiotherapy systems - Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz |
IEC 61846:1998 | Ultrasonics - Pressure pulse lithotripters - Characteristics of fields |
IEC 62555:2013 | Ultrasonics - Power measurement - High intensity therapeutic ultrasound (HITU) transducers and systems |
EN 61846:1998 | Ultrasonics - Pressure pulse lithotripters - Characteristics of fields |
IEC 60601-2-62:2013 | Medical electrical equipment - Part 2-62: Particular requirements for the basic safety and essential performance of high intensity therapeutic ultrasound (HITU) equipment |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
EN 61689:2013 | Ultrasonics - Physiotherapy systems - Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz |
EN 60601-1-2:2015 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
DIN 50100:2015-11 (Draft) | LOAD CONTROLLED FATIGUE TESTING - EXECUTION AND EVALUATION OF CYCLIC TESTS AT CONSTANT LOAD AMPLITUDES ON METALLIC SPECIMENS AND COMPONENTS |
EN 62555:2014 | Ultrasonics - Power measurement - High intensity therapeutic ultrasound (HITU) transducers and systems |
IEC TS 62556:2014 | Ultrasonics - Field characterization - Specification and measurement of field parameters for high intensity therapeutic ultrasound (HITU) transducers and systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.