BS EN 60601-2-31 : 2008
Current
The latest, up-to-date edition.
MEDICAL ELECTRICAL EQUIPMENT - PART 2-31: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF EXTERNAL CARDIAC PACEMAKERS WITH INTERNAL POWER SOURCE
Hardcopy , PDF
English
01-01-2008
INTRODUCTION
201.1 Scope, object and related standards
201.2 Normative references
201.3 Terms and definitions
201.4 General requirements
201.5 General requirements for testing ME EQUIPMENT
201.6 Classification of ME EQUIPMENT and ME SYSTEMS
201.7 ME EQUIPMENT identification, marking and documents
201.8 Protection against electrical HAZARDS from ME
EQUIPMENT
201.9 Protection against MECHANICAL HAZARDS of ME
EQUIPMENT and ME SYSTEMS
201.10 Protection against unwanted and excessive radiation
HAZARDS
201.11 Protection against excessive temperatures and other
HAZARDS
201.12 Accuracy of controls and instruments and protection
against hazardous outputs
201.13 HAZARDOUS SITUATIONS and fault conditions
201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)
201.15 Construction of ME EQUIPMENT
201.16 ME SYSTEMS
201.17 Electromagnetic compatibility of ME EQUIPMENT and ME
SYSTEMS
202 Electromagnetic compatibility - Requirements and tests
Annexes
Annex AA (informative) - Particular guidance and rationale
Bibliography
Index of defined terms used in this particular standard
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Annex ZZ (informative) - Coverage of Essential Requirements
of EC Directives
Pertains to the BASIC SAFETY and ESSENTIAL PERFORMANCE of EXTERNAL PACEMAKERS powered by an INTERNAL ELECTRICAL POWER SOURCE, hereafter referred to as ME EQUIPMENT.
Committee |
CH/150/2
|
DevelopmentNote |
Supersedes 91/53412 DC. (11/2005) Supersedes BS 5724-2.31(1995) and 07/30165025 DC. To be read in conjunction with BS EN 60601-1. (08/2009) 2008 Edition remains current. 2008 Edition Re-issued in September 2011 & incorporates AMD 1 2011. (10/2011)
|
DocumentType |
Standard
|
Pages |
40
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
Standards | Relationship |
IEC 60601-2-31:2008+AMD1:2011 CSV | Identical |
DIN EN 60601-2-31 : 2012 | Identical |
EN 60601-2-31:2008/A1:2011 | Identical |
UNE-EN 60601-2-31:2009 | Identical |
SN EN 60601-2-31 : 1995 AMD 1 1998 | Identical |
I.S. EN 60601-2-31:2008 | Identical |
AAMI PC69 : 2007 | |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
EN 60601-1-2:2015 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
ISO 14708-2:2012 | Implants for surgery Active implantable medical devices Part 2: Cardiac pacemakers |
ISO 14708-1:2014 | Implants for surgery — Active implantable medical devices — Part 1: General requirements for safety, marking and for information to be provided by the manufacturer |
IEC 60086-2:2015 | Primary batteries - Part 2: Physical and electrical specifications |
IEC 60086-1:2015 | Primary batteries - Part 1: General |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.