BS EN 60598-2-20:2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Luminaires Particular requirements. Lighting chains
Hardcopy , PDF
07-04-2024
English
02-28-2017
20.1 Scope
20.2 Normative references
20.3 Terms and definitions
20.4 General test requirements
20.5 Classification of luminaires
20.6 Marking
20.7 Construction
20.8 Creepage distances and clearances
20.9 Provisions for earthing
20.10 Terminals
20.11 External and internal wiring
20.12 Protection against electric shock
20.13 Endurance tests and thermal tests
20.14 Resistance to dust, solid objects and moisture
20.15 Insulation resistance and electric strength
20.16 Resistance to heat, fire and tracking
Annex A (normative) - Requirements for interconnecting
connectors for use in lighting chains
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Defines requirements for lighting chains fitted with series, parallel or a combination of series/parallel connected light sources for use either indoors or outdoors on supply voltages not exceeding 250 V.
Committee |
CPL/34/4
|
DevelopmentNote |
Supersedes 95/213328 DC, 96/212327 DC, 97/202715 DC and 99/240871 DC (08/2004) Supersedes 08/30181642 DC. (10/2010) 2010 Edition remains active & will be withdrawn on 30/12/2017. Supersedes 12/30267896 DC. (01/2015)
|
DocumentType |
Standard
|
Pages |
24
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This part of IEC60598 specifies requirements for lighting chains fitted with series, parallel or a combination of series/parallel connected light sources for use either indoors or outdoors on supply voltages not exceeding 250V. For combinations where rope lights (also known as sealed lighting chains) are included, see IEC60598‑2‑21 . Lighting chains provided with fixed or detachable attachments e.g. ornamental or decorative, are considered to be covered by this standard. For lighting chains fitted with lampholders of the push-in type, the appropriate requirements of this standard applies. NOTE1 A Christmas tree lighting chain is an example of a lighting chain fitted with series or series/parallel connected lamps. A chain for illuminating ski-tracks or promenades is an example of a lighting chain fitted with parallel connected lamps. For lighting chains with non-standardised lamps (e.g. lamps of the push-in type) the lamps are regarded as a part of the lighting chain and consequently included in the testing. NOTE2 For products where the lighting chain is permanently fixed to a frame or pre-lit Christmas tree the relevant clauses of IEC60598‑2‑4 and/or IEC60598‑2‑7 can also apply. NOTE3 In some countries the term \'strings\' is used instead of \'chains\'. NOTE4 Candlestick luminaries are tested according to IEC60598‑2‑4 .
Standards | Relationship |
IEC 60598-2-20:2014/COR1:2016 | Identical |
EN 60598-2-20:2015/AC:2017-01 | Identical |
IEC 60598-2-20:2014 | Identical |
UNE-EN 60598-2-20:2015 | Identical |
I.S. EN 60598-2-20:2015 | Identical |
NEN EN 60598-2-20 : AMD 11 95 | Identical |
DIN EN 60598-2-20 : 2015 COR 1 2017 | Identical |
EN 60598-2-20:2015 | Equivalent |
SN EN 60598-2-20 : 2015 COR 2017 | Identical |
IEC 60238:2016+AMD1:2017 CSV | Edison screw lampholders |
IEC 61984:2008 | Connectors - Safety requirements and tests |
EN 60238 : 2004 AMD 2 2011 | EDISON SCREW LAMPHOLDERS (IEC 60238:2004/A2:2011) |
IEC 61347-2-13:2014+AMD1:2016 CSV | Lamp controlgear - Part 2-13: Particular requirements for d.c. ora.c. supplied electronic controlgear for LED modules |
EN 61347-2-13:2014/A1:2017 | LAMP CONTROLGEAR - PART 2-13: PARTICULAR REQUIREMENTS FOR D.C. OR A.C. SUPPLIED ELECTRONIC CONTROLGEAR FOR LED MODULES |
IEC 61347-2-11:2001+AMD1:2017 CSV | Lamp controlgear - Part 2-11: Particular requirements for miscellaneous electronic circuits used with luminaires |
EN 60598-2-21:2015/AC:2017-01 | LUMINAIRES - PART 2-21: PARTICULAR REQUIREMENTS - ROPE LIGHTS (IEC 60598-2-21:2014/COR1:2016) |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60245-4:2011 | Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 4: Cords and flexible cables |
IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
EN 61184:2017 | Bayonet lampholders |
EN 61984:2009 | Connectors - Safety requirements and tests |
ISO 4046-4:2002 | Paper, board, pulps and related terms Vocabulary Part 4: Paper and board grades and converted products |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 61184:2017 | Bayonet lampholders |
IEC 60227-5:2011 | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 5: Flexible cables (cords) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.