BS EN 60439-4:2004
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Low-voltage switchgear and controlgear assemblies Particular requirements for assemblies for construction sites (ACS)
Hardcopy , PDF
03-31-2013
English
01-11-2005
1 General
1.1 Scope and object
1.2 Normative references
2 Definitions
3 Classification of ASSEMBLIES
4 Electrical characteristics of ASSEMBLIES
5 Information to be given regarding the ASSEMBLY
5.1 Nameplates
6 Service conditions
6.1 Normal service conditions
7 Design and construction
7.1 Mechanical design
7.2 Enclosure and degree of protection
8 Test specifications
8.1 Classification of tests
8.2 Type tests
Applies to type-tested ASSEMBLIES (TTA) intended for use on construction sites, i.e. temporary places of work to which the public do not generally have access and where building construction, installation, repairs, alteration or demolition of property (buildings) or civil engineering (public works) or excavation or any other similar operations are carried out.
Committee |
PEL/17
|
DevelopmentNote |
Also numbered as IEC 60439-4: 1990. Supersedes 90/25373 DC & 94/214118 DC (05/2004) Supersedes 03/100155 DC. (01/2005)
|
DocumentType |
Standard
|
Pages |
26
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Applies to type-tested ASSEMBLIES (TTA) intended for use on construction sites, i.e. temporary places of work to which the public do not generally have access and where building construction, installation, repairs, alteration or demolition of property (buildings) or civil engineering (public works) or excavation or any other similar operations are carried out. These ASSEMBLIES may be transportable (semi-fixed) or mobile. This standard does not apply to ASSEMBLIES for use in the administrative centres of construction sites (offices, cloakrooms, ASSEMBLY rooms, canteens, restaurants, dormitories, toilets, etc.). The nominal primary voltage and the nominal secondary voltage of transformers incorporated in ACS shall be within the limits specified in IEC 60439-1. Requirements for electrical protection provided by equipment manufactured according to this International Standard shall comply with the requirements given in IEC 60364-7-704. NOTE: This standard may be used as a guide to partially type-tested ASSEMBLIES (PTTA) constructed according to agreement between manufacturer and user taking into account the nature of supply and/or distribution network and relevant installation requirements. The following major changes with respect to edition 1 (including amendments 1 and 2) have been incorporated: - introduction of the definition for \'rated current of ACS\'; - replacement of classification based on the rated current of ACS by classification based on the function as assigned by the manufacturer; - amended requirements for the protection of socket-outlets with reference to the more comprehensive requirements of IEC 60364-7-704; - introduction of common requirements for all types of ACS.
Standards | Relationship |
UNE-EN 60439-4:2005 | Identical |
NBN EN 60439-4 : 2005 | Identical |
SN EN 60439-4 : 2004 | Identical |
I.S. EN 60439-4:2004 | Identical |
IEC 60439-4:2004 | Identical |
EN 60439-4:2004 | Identical |
NF EN 60439-4 : 2005 | Identical |
DIN EN 60439-4 : 2005 | Identical |
BS 7375:1996 | Code of practice for distribution of electricity on construction and building sites |
BS 7375:2010 | Distribution of electricity on construction and demolition sites. Code of practice |
BS 7909:1998 | Code of practice for design and installation of temporary distribution systems delivering a.c. electrical supplies for lighting, technical services and other entertainment related purposes |
13/30275065 DC : 0 | BS 4363+A1 - SPECIFICATION FOR DISTRIBUTION ASSEMBLIES FOR REDUCED LOW VOLTAGE ELECTRICITY SUPPLIES FOR CONSTRUCTION AND BUILDING SITES |
09/30205684 DC : 0 | BS 7375 - CODE OF PRACTICE FOR DISTRIBUTION OF ELECTRICITY ON CONSTRUCTION AND BUILDING SITES |
BS 8488(2009) : 2009 | PREFABRICATED WIRING SYSTEMS INTENDED FOR PERMANENT CONNECTION IN FIXED INSTALLATIONS - SPECIFICATION |
EN 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
IEC 60364-5-53:2001+AMD1:2002+AMD2:2015 CSV | Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control |
IEC 61558-2-23:2010 | Safety of transformers, reactors, power supply units and combinations thereof - Part 2-23: Particular requirements and tests for transformers and power supply units for construction sites |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60364-7-704:2017 | Low-voltage electrical installations - Part 7-704: Requirements for special installations or locations - Construction and demolition site installations |
HD 384.7.704 S1:2000 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - SECTION 704: CONSTRUCTION AND DEMOLITION SITE INSTALLATIONS |
IEC 60439-1:1999+AMD1:2004 CSV | Low-voltage switchgear and controlgear assemblies - Part 1: Type-tested and partially type-tested assemblies |
EN 60439-1:1999/A1:2004 | LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1 - TYPE TESTED AND PARTIALLY TYPE TESTED ASSEMBLIES |
IEC 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
EN 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
EN 61558-2-23:2010 | Safety of transformers, reactors, power supply units and combinations thereof - Part 2-23: Particular requirements and tests for transformers and power supply units for construction sites |
IEC 60309-1:1999+AMD1:2005+AMD2:2012 CSV | Plugs, socket-outlets and couplers for industrial purposes - Part 1: General requirements |
EN 60309-2:1999/A2:2012 | PLUGS, SOCKET-OUTLETS AND COUPLERS FOR INDUSTRIAL PURPOSES - PART 2: DIMENSIONAL INTERCHANGEABILITY REQUIREMENTS FOR PIN AND CONTACT-TUBE ACCESSORIES (IEC 60309-2:1999/A2:2012) |
IEC 60309-2:1999+AMD1:2005+AMD2:2012 CSV | Plugs, socket-outlets and couplers for industrial purposes - Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories |
EN 60309-1:1999/A1:2007/AC:2014 | PLUGS, SOCKET-OUTLETS AND COUPLERS FOR INDUSTRIAL PURPOSES - PART 1: GENERAL REQUIREMENTS (IEC 60309-1:1999/A2:2012) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.