BS EN 60269-2:1995
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Low-voltage fuses Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application)
Hardcopy , PDF
06-29-2007
English
09-24-2002
Committees responsible
National foreword
Foreword
1 General
1.1 Scope
1.2 Object
4 Classification
5 Characteristics of fuses
5.3.2 Rated currents of the fuse-holder
5.5 Rated power dissipation of a fuse-link
and rated power acceptance of a fuse-holder
5.6 Limits of time-current characteristics
5.7.2 Rated breaking capacity
6 Marking
6.1 Markings of the fuse-holders
6.2 Markings of the fuse-links
7.2 Insulating properties
7.6 Cut-off current characteristics
7.7 I2t characteristics
8 Tests
8.4.3.3 Verification of time-current
characteristics and gates
8.9.1 Verification of resistance to heat
of the fuse-holder
8.11.1 Mechanical strength
Figure 1 - Time-current zone 'aM'
Table A - Gates for 'aM' fuse-links (all rated currents)
Table B - Minimum rated breaking capacities
Table C - Maximum operating I2t values for 'aM' fuse-links
Table D - Cross-sectional areas of copper conductors for the
test of 'aM' fuse-links
Requirements supplementary to those of Part 1 for fuses generally intended to be used in installations where the fuse-links are accessible to authorized persons only.
Committee |
PEL/32
|
DevelopmentNote |
Renumbers and supersedes BS 88-2.1(1988). 1995 version incorporates amendment 8741 to BS 88-2.1(1988). Supersedes BS 88-2(1975), 00/201931 DC and 79/21092 DC. (10/2005).
|
DocumentType |
Standard
|
Pages |
12
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
NBN EN 60269-2 : 98 AMD 3 2002 | Identical |
EN 60269-2:1995/A2:2002 | Identical |
NF EN 60269-2 : 96 AMD 2 2002 | Identical |
SN EN 60269-2 : 1995 AMD 1 1998 | Identical |
I.S. EN 60269-2:1996 | Identical |
DIN EN 60269-2 : 2002 | Identical |
UNE-EN 60269-2:1996 | Identical |
BS 7671(2008) : 2018 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 7430:1998 | Code of practice for earthing |
BS 3535-1(1996) : 1996 | ISOLATING TRANSFORMERS AND SAFETY ISOLATING TRANSFORMERS - REQUIREMENTS |
BS EN 60269-3:1995 | BS Low-voltage fuses Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household and similar applications) |
BS 88-3.1(1995) : 1995 | LOW-VOLTAGE FUSES - PART 3: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY UNSKILLED PERSONS (FUSES MAINLY FOR HOUSEHOLD AND SIMILAR APPLICATIONS) |
BS EN 60742:1996 | Isolating transformers and safety isolating transformers. Requirements |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
EN 60742:1995 | Isolating transformers and safety isolating transformers - Requirements |
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV | Low-voltage fuses - Part 1: General requirements |
IEC 60269-2-1:2004 | Low-voltage fuses - Part 2-1: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Sections I to VI: Examples of types of standardized fuses |
EN 60269-1:2007/A2:2014 | LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS (IEC 60269-1:2006/A2:2014) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.