BS EN 60228:2005
Current
The latest, up-to-date edition.
Conductors of insulated cables
Hardcopy , PDF
English
05-31-2007
FOREWORD
INTRODUCTION
1 Scope
2 Terms and definitions
3 Classification
4 Materials
4.1 Introduction
4.2 Solid aluminium conductors
4.3 Circular and shaped stranded aluminium conductors
5 Solid conductors and stranded conductors
5.1 Solid conductors (class 1)
5.1.1 Construction
5.1.2 Resistance
5.2 Stranded circular non-compacted conductors (class 2)
5.2.1 Construction
5.2.2 Resistance
5.3 Stranded compacted circular conductors and stranded
shaped conductors (class 2)
5.3.1 Construction
5.3.2 Resistance
6 Flexible conductors (classes 5 and 6)
6.1 Construction
6.2 Resistance
7 Check of compliance with Clauses 5 and 6
Annex A (normative) Measurement of resistance
Annex B (informative) Exact formulae for the temperature
correction factors
Annex C (informative) Guide to the dimensional limits of
circular conductors
Annex ZA (normative) Special national conditions
Defines the nominal cross-sectional areas, in the range 0.5 mm[2] to 2500 mm[2], for conductors in electric power cables and cords of a wide range of types.
Committee |
GEL/20/16
|
DevelopmentNote |
Supersedes 02/203210 DC. (04/2005)
|
DocumentType |
Standard
|
Pages |
22
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
Standards | Relationship |
UNE-EN 60228:2005 | Identical |
NF EN 60228 : 2005 | Identical |
EN 60228:2005 COR 2005 | Identical |
IEC 60228:2004 | Identical |
NBN EN 60228 : 2006 | Identical |
I.S. EN 60228:2005 | Identical |
DIN EN 60228 : 2005 | Identical |
EN 60228:2005 | Identical |
14/30295204 DC : 0 | BS 7629-1 - ELECTRIC CABLES - SPECIFICATION FOR 300/500 V FIRE RESISTANT SCREENED CABLES HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE FOR FIXED INSTALLATIONS - PART 1: MULTICORE CABLES |
BS 8450:2006 | Code of practice for installation of electrical and electronic equipment in ships |
07/30169733 DC : 0 | BS 5467 AMD3 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1900/3300 V |
05/30138596 DC : DRAFT SEP 2005 | BS 6195 - ELECTRIC CABLES - INSULATED FLEXIBLE CABLES AND CORDS FOR COIL LEADS |
BS 4737-3.30:2015 | Intruder alarm systems Specifications for components - Specification for PVC insulated cables for interconnecting wiring |
BS 7889:2012 | Electric cables. Thermosetting insulated, non-armoured cables with a voltage of 600/1 000 V, for fixed installations |
07/30143023 DC : DRAFT MAR 2007 | BS 7835 - ELECTRIC CABLES - ARMOURED CABLES WITH THERMOSETTING INSULATION FOR RATED VOLTAGES FROM 3.8/6.6 KV TO 19/33 KV HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - REQUIREMENTS AND TEST METHODS |
11/30214073 DC : 0 | BS 7870-4.10 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.10: SINGLE-CORE 11 KV AND 33 KV CABLES |
BS 7609(1992) : 1992 | CODE OF PRACTICE FOR INSTALLATION AND INSPECTION OF UNINSULATED COMPRESSION AND MECHANICAL CONNECTORS FOR POWER CABLES WITH COPPER OR ALUMINIUM CONDUCTORS |
11/30214068 DC : 0 | BS 7870-3.40 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.40: XLPE INSULATED, COPPER WIRE WAVEFORM CONCENTRIC CABLES WITH SOLID ALUMINIUM CONDUCTORS |
BS 7870-4.10(2011) : 2011 | LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION OF RATED VOLTAGES OF 11 KV TO 33 KV - SECTION 4.10: SINGLE-CORE 11 KV TO 33 KV CABLES (IMPLEMENTATION OF HD 620) |
BS 7846:2015 | Electric cables. Thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1 000 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification |
BS 7629-1:2015+A1:2019 | Electric cables. Specification for 300/500 V fire resistant, screened, fixed installation cables having low emission of smoke and corrosive gases when affected by fire Multicore cables |
BS 7870-4.11(2011) : 2011 | LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.11: SINGLE-CORE 33 KV LEAD SHEATHED CABLES (IMPLEMENTATION OF HD 620) |
BS 7671(2008) : 2018 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 7870-4.20(2011) : 2011 | LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV TO 33 KV - SECTION 4.20: THREE-CORE 11 KV CABLES (IMPLEMENTATION OF HD 620) |
BS 7846:2009 | Electric cables. Thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1000 V, having low emission of smoke and corrosive gases when affected by fire. Specification |
BS 7430(2011) : 2011 | CODE OF PRACTICE FOR PROTECTIVE EARTHING OF ELECTRICAL INSTALLATIONS |
BS 8436:2011 | Electric cables. Specification for 300/500 V screened electric cables having low emission of smoke and corrosive gases when affected by fire, for use in walls, partitions and building voids. Multicore cables |
DEFSTAN 61-12(PT9)/5(2008) : 2008 | WIRES, CORDS AND CABLES ELECTRICAL - METRIC UNITS - PART 9: CABLES AND WIRES ELECTRICAL FOR CABLES, RADIO FREQUENCY INCLUDING LIMITED FIRE HAZARD (LFH) VARIANTS |
DEFSTAN 61-12(PT18)/5(2006) : 2006 | WIRES, CORDS AND CABLES, ELECTRICAL - PART 18: EQUIPMENT WIRES LIMITED FIRE HAZARD |
DEFSTAN 61-12(PT6)/7(2009) : 2009 | WIRES, CORDS, AND CABLES, ELECTRICAL-METRIC UNITS - PART 6: CABLES, POLYVINYL CHLORIDE (PVC), POLYETHYLENE, OR SILICONE RUBBER INSULATED EQUIPMENT WIRES |
11/30214061 DC : 0 | BS 7870-3.12 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.12: XLPE INSULATED COMBINED NEUTRAL AND EARTH COPPER WIRE CONCENTRIC CABLES WITH COPPER OR ALUMINIUM CONDUCTORS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE |
11/30219798 DC : 0 | BS 7870-5 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 5: POLYMERIC INSULATED AERIAL BUNDLED CONDUCTORS (ABC) OF RATED VOLTAGE 0.6/1 KV FOR OVERHEAD DISTRIBUTION |
BS PAS 5308-1(2009) : 2009 | CONTROL AND INSTRUMENTATION CABLES - PART 1: SPECIFICATION FOR POLYETHYLENE INSULATED CABLES |
12/30248753 DC : 0 | BS 6004 - ELECTRIC CABLES - PVC INSULATED, NON-ARMOURED CABLES FOR VOLTAGES UP TO AND INCLUDING 460/750 V, FOR ELECTRIC POWER, LIGHTING AND INTERNAL WIRING |
15/30301501 DC : 0 | BS 5467 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1900/3300 V, FOR FIXED INSTALLATIONS - SPECIFICATION |
15/30325295 DC : 0 | BS 8592 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED, FIRE-RESISTANT, SINGLE CORE NON-SHEATHED CABLES OF RATED VOLTAGE 450/750 V, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - SPECIFICATION |
14/30295317 DC : 0 | BS 4737-3.30 - INTRUDER ALARM SYSTEMS - PART 3: SPECIFICATIONS FOR OMPONENTS - SECTION 30: SPECIFICATION FOR PVC INSULATED CABLES FOR INTERCONNECTING WIRING |
11/30249994 DC : DRAFT JULY 2011 | BS 7430 - CODE OF PRACTICE FOR PROTECTIVE EARTHING OF ELECTRICAL INSTALLATIONS |
12/30248745 DC : 0 | BS 7211 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED CABLES FOR VOLTA GES UP TO AND INCLUDING 450/750 V, FOR ELECTRIC POWER, LIGHTING AND INTERNAL WIRING, AND HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE |
12/30244462 DC : 0 | BS 8573 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED CABLES WITH A VOLTAGE OF 600/1000 V, FOR FIXED INSTALLATIONS, HAVING LOW EMISSIONS OF SMOKE AND CORROSIVE WHEN AFFECTED BY FIRE |
06/30143016 DC : DRAFT SEP 2006 | BS 6622 - SPECIFICATION FOR CABLES WITH THERMOSETTING INSULATION FOR RATED VOLTAGES FROM 3.8/6.6 KV TO 19/33 KV |
BS 7870-3.11:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors |
DEFSTAN 02-526/2(2008) : 2008 | REQUIREMENTS FOR CABLES ELECTRIC, ELASTOMERIC, LIMITED FIRE HAZARD SHEATHED FOR GENERAL SERVICES |
BS 6231:2006 | Electric cables. Single core PVC insulated flexible cables of rated voltage 600/1000 V for switchgear and controlgear wiring |
BS 6195:2006 | Electric cables. Rubber or silicone rubber insulated flexible cables and cords for coil end leads |
BS 6622:2007 | Electric cables. Armoured cables with thermosetting insulation for rated voltages from 3.8/6.6 kV to 19/33 kV. Requirements and test methods |
BS 7870-3.12:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors, having low emission of smoke and corrosive gases when affected by fire |
BS 6724(1997) : 1997 | ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1900/3300 V, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE |
BS 7970:2012 | Electric cables. Metal foil and longitudinally welded aluminium sheath constructions of power cables having XLPE insulation for rated voltages from 66 kV (U<sub>m</sub> = 72.5 kV) to 132 kV (U<sub>m</sub> = 145 kV) |
BS 5467(1997) : 1997 | ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1900/3300 V |
BS 7594:2011 | Code of practice for audio-frequency induction-loop systems (AFILS) |
BS 7912(2012) : 2012 | POWER CABLES WITH XLPE INSULATION AND METAL SHEATH, AND THEIR ACCESSORIES, FOR RATED VOLTAGES FROM 66 KV (U[M] = 72.5 KV) TO 132 KV (U[M] = 145 KV) |
BS 7835:2007 | Electric cables. Armoured cables with thermosetting insulation for rated voltages from 3.8/6.6 kV to 19/33 kV having low emission of smoke and corrosive gases when affected by fire. Requirements and test methods |
BS 7870-3.21:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated split concentric cables with copper or aluminium conductors |
BS 7870-5:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Polymeric insulated aerial bundled conductors (ABC) of rated voltage 0.6/1 kV for overhead distribution |
BS 7870-3.40:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated, copper wire waveform concentric cables with solid aluminium conductors |
BS 6724:2016 | Electric cables. Thermosetting insulated, armoured cables of rated voltages of 600/1 000 V and 1 900/3 300 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification |
BS 7870-3.50:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated, copper wire waveform or helical concentric cables with solid aluminium conductors, having low emission of smoke and corrosive gases when affected by fire |
BS 6007:2006 | Electric cables. Single core unsheathed heat resisting cables for voltages up to and including 450/750 V, for internal wiring |
12/30244367 DC : 0 | BS 7912 - POWER CABLES WITH XLPE INSULATION AND METAL SHEATH, AND THEIR ACCESSORIES, FOR RATED VOLTAGES FROM 66 KV (U[M] = 72.5 KV) TO 132 KV (U[M] = 145 KV) |
11/30214071 DC : 0 | BS 7870-3.50 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.50: XLPE INSULATED, COPPER WIRE WAVEFORM OR HELICAL CONCENTRIC CABLES WITH SOLID ALUMINIUM CONDUCTORS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE |
15/30301742 DC : 0 | BS 7846 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED, FIRE-RESISTANT CABLES OF RATED VOLTAGE 600/1000 V FOR FIXED INSTALLATIONS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - REQUIREMENTS AND TEST METHODS |
13/30283398 DC : 0 | BS 7656+A1 - SPECIFICATION FOR LOW-VOLTAGE POLE-MOUNTING FUSES (CUT-OUTS) - 315 ARATING |
BS 7211:2012 | Electric cables. Thermosetting insulated and thermoplastic sheathed cables for voltages up to and including 450/750 V for electric power and lighting and having low emission of smoke and corrosive gases when affected by fire |
07/30169735 DC : 0 | BS 6724 AMD3 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1900/3300 V, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE |
BS PAS 5308-2(2009) : 2009 | CONTROL AND INSTRUMENTATION CABLES - PART 2: SPECIFICATION FOR PVC INSULATED CABLES |
BS 5467:2016 | Electric cables. Thermosetting insulated, armoured cables of rated voltages of 600/1 000 V and 1 900/3 300 V for fixed installations. Specification |
12/30244364 DC : 0 | BS 7970 - ELECTRIC CABLES - METAL FOIL AND LONGITUDINALLY WELDED ALUMINIUM SHEATH CONSTRUCTIONS OF POWER CABLES HAVING XLPE INSULATION FOR RATED VOLTAGES FROM 66 KV (U[M] = 72.5 KV) TO 132 KV (U[M] = 145 KV) |
11/30214059 DC : 0 | BS 7870-3.11 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.11: XLPE INSULATED COMBINED NEUTRAL AND EARTH COPPER WIRE CONCENTRIC CABLES WITH COPPER OR ALUMINIUM CONDUCTORS |
11/30214077 DC : 0 | BS 7870-4.20 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.20: THREE-CORE 11 KV CABLES |
11/30214065 DC : 0 | BS 7870-3.22 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.22: XLPE INSULATED SPLIT CONCENTRIC CABLES WITH COPPER OR ALUMINIUM CONDUCTORS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE |
BS 7870-2:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Methods of test |
11/30214075 DC : 0 | BS 7870-4.11 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.11: SINGLE-CORE 33 KV LEAD SHEATHED CABLES |
10/30228489 DC : 0 | BS 8436 - ELECTRIC CABLES - SPECIFICATION FOR 300/500 V SCREENED ELECTRIC CABLES HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE, FOR USE IN WALLS, PARTITIONS AND BUILDING VOIDS - MULTICORE CABLES |
08/30170023 DC : DRAFT JUNE 2008 | BS 7629-1 - ELECTRIC CABLES - SPECIFICATION FOR 300/500 V FIRE RESISTANT SCREENED CABLES HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - PART 1: MULTICORE AND MULTIPAIR CABLES |
11/30215743 DC : 0 | BS 7870-3.21 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.21: XLPE INSULATED SPLIT CONCENTRIC CABLES WITH COPPER OR ALUMINIUM CONDUCTORS |
09/30199575 DC : 0 | BS 7846 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED, FIRE-RESISTANT CABLES OF RATED VOLTAGE 600/1000 V HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - SPECIFICATION |
15/30301443 DC : 0 | BS 6724 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1 900/3300 V FOR FIXED INSTALLATIONS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - SPECIFICATION |
BS 7656(1993) : 1993 | SPECIFICATION FOR LOW-VOLTAGE POLE-MOUNTING FUSES (CUT-OUTS) - 400 A RATING |
BS 8592:2016 | Electric cables. Thermosetting insulated, non-armoured, fire-resistant, single core non-sheathed cables of rated voltage 450/750 V, having low emission of smoke and corrosive gases when affected by fire. Specification |
BS 7727:1994 | Code of practice for installation and inspection of pre-insulated compression terminals and connectors for cables with copper conductors up to 6 mm<sup>2</sup> |
BS 8573:2012 | Electric cables. Thermosetting insulated, non-armoured cables with a voltage of 600/1 000V, for fixed installations, having low emissions of smoke and corrosive gases when affected by fire |
12/30244369 DC : 0 | BS 7889 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED CABLES WITH A VOLTAGE OF 600/1000 V, FOR FIXED INSTALLATIONS |
05/30138592 DC : DRAFT SEP 2005 | BS 6231 - ELECTRIC CABLES - 600/1000 V, PVC INSULATED CABLES FOR SWITCHGEAR AND CONTROLGEAR WIRING |
11/30214057 DC : 0 | BS 7870-2 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 2: METHODS OF TEST |
BS 7870-3.22:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated split concentric cables with copper or aluminium conductors, having low emission of smoke and corrosive gases when affected by fire |
DEFSTAN 61-12(PT1)/4(2008) : 2008 | WIRES, CORDS AND CABLES, ELECTRICAL - PART 1: CABLES ELECTRICAL INSULATED FLEXIBLE CORDS AND FLEXIBLE CABLES |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 7629-1:2015 | Electric cables. Specification for 300/500 V fire resistant, screened, fixed installation cables having low emission of smoke and corrosive gases when affected by fire Multicore cables |
BS 6004:2012 | Electric cables. PVC insulated and PVC sheathed cables for voltages up to and including 300/500 V, for electric power and lighting |
BS 7629-1:2008 | Electric cables. Specification for 300/500 V fire resistant screened cables having low emission of smoke and corrosive gases when affected by fire Multicore and multipair cables |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.