BS EN 60204-11 : 2001
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 11: REQUIREMENTS FOR HV EQUIPMENT FOR VOLTAGES ABOVE 1000 V A.C. OR 1500 V D.C. AND NOT EXCEEDING 36 KV
Hardcopy , PDF
01-29-2019
English
01-01-2001
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
4 General requirements
5 Incoming supply conductor terminations, devices for
disconnecting and switching off, and means for earthing
6 Protection against electric shock
7 Protection of HV equipment
8 Equipotential bonding
9 Control circuits and control functions
10 Operator interface and machine-mounted control devices
11 Electronic equipment
12 Controlgear: location, mounting, and enclosures
13 Conductors and cables
14 Wiring practices
15 Electric motors and associated equipment
16 Accessories
17 Marking, warning signs and reference designations
18 Technical documentation
19 Testing and verification
Annex A (informative) - Examples of machines covered by this
part of IEC 60204
Annex B (informative) - Inquiry form for the HV equipment
of machines
Annex C (informative) - Method of calculation for the
cross-sectional area of bare protective conductors
in supply systems with direct earthing or low
impedance earthing of the neutral
Annex D (informative) - Relationship between cable rated
voltages and highest voltage for HV equipment
Annex E (informative) - Rationalization of the use of terms
relating to earthing and protective bonding
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Annex ZZ (informative) - Coverage of Essential Requirements
of EC Directives
Index
Pertains the electrical and electronic equipment and systems of machines, including a group of machines working together in a coordinated manner, but excluding higher level system aspects (i.e. communications between systems).
Committee |
GEL/44
|
DevelopmentNote |
Supersedes 99/242752 DC (04/2004)
|
DocumentType |
Standard
|
Pages |
62
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
NF EN 60204-11 : 2001 | Identical |
I.S. EN 60204-11:2000 | Identical |
EN 60204-11:2000/corrigendum:2010 | Identical |
SN EN 60204-11 : 2000 | Identical |
NBN EN 60204-11 : 2001 | Identical |
DIN EN 60204-11 : 2001 COR 1 2010 | Identical |
IEC 60204-11:2000 | Identical |
UNE-EN 60204-11:2002 | Identical |
PD 5304:2014 | Guidance on safe use of machinery |
PD 5304:2005 | GUIDANCE ON SAFE USE OF MACHINERY |
PD 5304:2000 | SAFE USE OF MACHINERY |
IEC 60364-5-54:2011 | Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors |
EN 60129:1994/A2:1996 | ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES |
IEC 60050-195:1998 | International Electrotechnical Vocabulary (IEV) - Part 195: Earthing and protection against electric shock |
HD 384.4.41 S2:1996/A1:2002 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 4: PROTECTION FOR SAFETY - CHAPTER 41: PROTECTION AGAINST ELECTRIC SHOCK |
EN 60034-1:2010/corrigendum Oct. 2010 | ROTATING ELECTRICAL MACHINES - PART 1: RATING AND PERFORMANCE |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
HD 384.2 : 200S2 | INTERNATIONAL ELECTROTECHNICAL VOCABULARY - ELECTRICAL INSTALLATIONS OF BUILDINGS |
EN 61230:2008 | LIVE WORKING - PORTABLE EQUIPMENT FOR EARTHING OR EARTHING AND SHORT-CIRCUITING |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
IEC 60204-1:2016 | Safety of machinery - Electrical equipment of machines - Part 1: General requirements |
EN 61310-3:2008 | Safety of machinery - Indication, marking and actuation - Part 3: Requirements for the location and operation of actuators |
IEC 61310-3:2007 | Safety of machinery - Indication, marking and actuation - Part 3: Requirements for the location and operation of actuators |
IEC 60076-5:2006 | Power transformers - Part 5: Ability to withstand short circuit |
HD 637 S1:1999/corrigendum:2005 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. |
IEC 61243-1:2003+AMD1:2009 CSV | Live working - Voltage detectors - Part 1: Capacitive type to be used for voltages exceeding 1 kV a.c. |
EN 50178:1997 | Electronic equipment for use in power installations |
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV | Common specifications for high-voltage switchgear and controlgear standards |
EN 60298:1996/A11:1999 | A.C. METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV |
IEC 60865-1:2011 | Short-circuit currents - Calculation of effects - Part 1: Definitions and calculation methods |
IEC 60129:1984 | Alternating current disconnectors and earthing switches |
HD 398.5 : S1 AMD 1 | POWER TRANSFORMERS - ABILITY TO WITHSTAND SHORT CIRCUIT |
HD 384.4.42 : S1 AMD 2 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS |
EN 60694:1996/A2:2001 | COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 60865-1:2012 | Short-circuit currents - Calculation of effects - Part 1: Definitions and calculation methods |
EN 61243-1:2005/A1:2010 | LIVE WORKING - VOLTAGE DETECTORS - PART 1: CAPACITIVE TYPE TO BE USED FOR VOLTAGES EXCEEDING 1 KV A.C. |
EN 60071-1:2006/A1:2010 | INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES |
IEC 61230:2008 | Live working - Portable equipment for earthing or earthing and short-circuiting |
IEC 60034-1:2017 | Rotating electrical machines - Part 1: Rating and performance |
HD 384.5.54 : 200S1 | ELECTRICAL INSTALLATION OF BUILDINGS - SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS |
IEC 60071-2:1996 | Insulation co-ordination - Part 2: Application guide |
EN 60071-2:1997 | Insulation co-ordination - Part 2: Application guide |
IEC 60050-826:2004 | International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
ISO 12100-1:2003 | Safety of machinery Basic concepts, general principles for design Part 1: Basic terminology, methodology |
EN 60420:1993 | High-voltage alternating current switch-fuse combinations |
IEC 61310-1:2007 | Safety of machinery - Indication, marking and actuation - Part 1: Requirements for visual, acoustic and tactile signals |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
ISO 3864:1984 | Safety colours and safety signs |
IEC 60364-4-42:2010+AMD1:2014 CSV | Low-voltage electrical installations - Part 4-42: Protection forsafety - Protection against thermal effects |
EN 61310-1:2008 | Safety of machinery - Indication, marking and actuation - Part 1: Requirements for visual, acoustic and tactile signals |
IEC 60445:2017 | Basic and safety principles for man-machine interface, marking and identification - Identification of equipment terminals, conductor terminations and conductors |
IEC 60298:1990 | A.C. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
EN 60204-1 : 2006 COR 2010 | SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 1: GENERAL REQUIREMENTS |
IEC 60420:1990 | High-voltage alternating current switch-fuse combinations |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.