Miniature fuses Miniature fuse-links for special applications
Hardcopy , PDF
English
02-29-2016
Committee |
PEL/32
|
DevelopmentNote |
2013 Edition includes corrigendum (correction notice). Supersedes 10/30215969 DC. (08/2013) 2013 Edition remains active and will be withdrawn on 27/10/2018. Supersedes 14/30301133 DC. (02/2016)
|
DocumentType |
Standard
|
Pages |
36
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
IEC 60127-7:2015 covers requirements for miniature fuse-links for special applications. This part of IEC 60127 is applicable to fuse-links with a rated voltage not exceeding 1 000 V, a rated current not exceeding 20 A and a rated breaking capacity not exceeding 50 kA. It does not apply to fuses completely covered by the subsequent parts of IEC 60269-1. It does not apply to miniature fuse-links for appliances intended to be used under special conditions, such as in corrosive or explosive atmospheres. This part of IEC 60127 applies in addition to the requirements of IEC 60127-1. Miniature fuse-links for special applications are not intended to be replaced by the end-user of an electrical/electronic appliance. The object of this part of IEC 60127 is to establish uniform test methods for miniature fuse-links for special applications, so as to allow verification of the values (for example melting time and breaking capacity values) specified by the manufacturer. This second edition cancels and replaces the first edition published in 2013. This edition includes the following significant technical changes with respect to the previous edition:
- defining a test board for surface mount fuse-links, Figure 2;
- defining test schedules for homogenous series.
This publication is to be read in conjunction with IEC 60127-1:2006. Keywords: fuse-links with a rated voltage not exceeding 1 000 V, a rated current not exceeding 20 A and a rated breaking capacity not exceeding 50 kA.
Standards | Relationship |
EN 60068-2-14:2009 | Identical |
IEC 60127-7:2015 | Identical |
EN 60127-7:2016 | Identical |
IEC 60127-6:2014 | Miniature fuses - Part 6: Fuse-holders for miniature fuse-links |
IEC 60695-4:2012 | Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products |
IEC 61249-2-7:2002 | Materials for printed boards and other interconnecting structures - Part 2-7: Reinforced base materials clad and unclad - Epoxide woven E-glass laminated sheet of defined flammability (vertical burning test), copper-clad |
EN 60127-6:2014 | Miniature fuses - Part 6: Fuse-holders for miniature fuse-links |
EN 60127-1:2006/A2:2015 | MINIATURE FUSES - PART 1: DEFINITIONS FOR MINIATURE FUSES AND GENERAL REQUIREMENTS FOR MINIATURE FUSE-LINKS |
IEC 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
ISO 3:1973 | Preferred numbers Series of preferred numbers |
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV | Low-voltage fuses - Part 1: General requirements |
IEC 60127-1:2006+AMD1:2011+AMD2:2015 CSV | Miniature fuses - Part 1: Definitions for miniature fuses andgeneral requirements for miniature fuse-links |
EN 61249-2-7:2002/corrigendum:2005 | MATERIALS FOR PRINTED BOARDS AND OTHER INTERCONNECTING STRUCTURES - PART 2-7: REINFORCED BASE MATERIALS CLAD AND UNCLAD - EPOXIDE WOVEN E-GLASS LAMINATED SHEET OF DEFINED FLAMMABILITY (VERTICAL BURNING TEST), COPPER-CLAD |
IEC 60695-2-13:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-13: Glowing/hot-wire based test methods- Glow-wire ignition temperature (GWIT) test method for materials |
EN 60695-2-13:2010/A1:2014 | FIRE HAZARD TESTING - PART 2-13: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE IGNITION TEMPERATURE (GWIT) TEST METHOD FOR MATERIALS (IEC 60695-2-13:2010/A1:2014) |
IEC 60695-2-12:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods- Glow-wire flammability index (GWFI) test method for materials |
EN 60695-4:2012 | FIRE HAZARD TESTING - PART 4: TERMINOLOGY CONCERNING FIRE TESTS FOR ELECTROTECHNICAL PRODUCTS (IEC 60695-4:2012) |
EN 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60127-4:2005+AMD1:2008+AMD2:2012 CSV | Miniature fuses - Part 4: Universal modular fuse-links (UMF) -Through-hole and surface mount types |
EN 60127-4:2005/A2:2013 | Miniature fuses - Part 4: Universal modular fuse-links (UMF) - Through-hole and surface mount types |
EN 60695-2-12:2010/A1:2014 | FIRE HAZARD TESTING - PART 2-12: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE FLAMMABILITY INDEX (GWFI) TEST METHOD FOR MATERIALS (IEC 60695-2-12:2010/A1:2014) |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.