INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 Preferred standard ratings and classifications for
   fuse-holders
6 Marking
7 Clause deleted
8 General notes on tests
9 Protection against electric shock
10 Clearances and creepage distances
11 Electrical requirements
12 Mechanical requirements
13 Thermal requirements
14 Endurance
15 Additional requirements
Annex A (normative) - Test PC board for fuse-holders of rated currents
        up to 10 A
Annex B (normative) - Type tests, test sequences and number of
        samples
Annex C (informative) - Insulation coordination
Annex D (informative) - Additional tests and requirements
Annex E (informative) - Information for the correct application of
        the fuse-holder
Bibliography
Annex ZA (normative) - Normative references to international
         publications with their corresponding
         European publications

Describes uniform requirements for safety and the assessment of electrical, mechanical, thermal and climatic properties of fuse-holders and the compatibility between fuse-holders and fuse-links.

Committee
PEL/32
DevelopmentNote
Supersedes 00/200718 DC, 90/33780 DC and 94/200241 DC. (08/2003) 1994 Edition along with its amendments remain current and will be withdrawn on 08/10/2017. Supersedes 12/30259014 DC. (11/2014)
DocumentType
Standard
Pages
60
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

This part of IEC60127 is applicable to fuse-holders for miniature cartridge fuse-links according to IEC60127‑2 and sub-miniature fuse-links according to IEC60127‑3 for the protection of electric appliances, electronic equipment and component parts thereof, normally intended for use indoors. Examples of fuse-holder types with different features are given in Table1. Table1 Features of unexposed or exposed fuse-holders 1 Types of mounting 1.1 Panel and base mounting 1.2 Printed circuit board mounting 2 Methods of fastening 2.1 Methods of fastening on panel: 2.1.1 Fixing nut fastening (threaded nut) 2.1.2 Snap-in fastening: 2.1.2.1 Fuse-base with an integral spring system 2.1.2.2 Fuse-base with a separate spring-nut (a nut fabricated, e.g. from thin spring steel having an impression designed to accommodate the mating part) 2.2 Methods of fastening on printed circuit (PC) board: 2.2.1 Solder fastening 2.2.2 Plug-in fastening 3 Methods of insertion of the fuse-carrier into the fuse base 3.1 Screw insertion 3.2 Bayonet insertion 3.3 Plug-in insertion 4 Types of terminals 4.1 Screw terminals 4.2 Solder terminals 4.3 Quick connect terminals 4.4 Other solderless terminals: - crimp terminals - wire wrap terminals 5 Protection against electric shock 5.1 Fuse-holder without integral protection against electric shock 5.2 Fuse-holder with integral protection against electric shock 5.3 Fuse-holder with enhanced integral protection against electric shock NOTE This list is not intended to be comprehensive and fuse-holders which are not listed are not necessarily excluded from the scope. This part of IEC60127 applies to fuse-holders with: a maximum rated current of 16A; and a maximum rated voltage of 1500V d.c. or 1000V a.c.; and for use up to 2000m above sea-level, unless otherwise specified. The object of this standard is to establish uniform requirements for safety and the assessment of electrical, mechanical, thermal and climatic properties of fuse-holders and the compatibility between fuse-holders and fuse-links.

Standards Relationship
DIN EN 60127-6 : 2015 Identical
NBN EN 60127-6 : 2014 Identical
NF EN 60127-6 : 2014 Identical
EN 60127-6:2014 Identical
IEC 60127-6:2014 Identical
I.S. EN 60127-6:2014 Identical
UNE-EN 60127-6:1997 Identical
SN EN 60127-6 : 2014 Identical

BS 1075:1989 Specification for tungsten halogen lamps (non vehicle)

IEC 60112:2003+AMD1:2009 CSV Method for the determination of the proof and the comparative tracking indices of solid insulating materials
EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
EN 60216-1:2013 Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results
IEC 60127-3:2015 Miniature fuses - Part 3: Sub-miniature fuse-links
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-20:2008 Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads
EN 60068-2-20:2008 Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60050-151:2001 International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices
EN 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
EN 60127-1:2006/A2:2015 MINIATURE FUSES - PART 1: DEFINITIONS FOR MINIATURE FUSES AND GENERAL REQUIREMENTS FOR MINIATURE FUSE-LINKS
IEC 60050-441:1984 International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses
IEC 60068-2-21:2006 Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
IEC 60050-212:2010 International Electrotechnical Vocabulary (IEV) - Part 212: Electrical insulating solids, liquids and gases
IEC 61210:2010 Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements
ISO 3:1973 Preferred numbers Series of preferred numbers
EN 60127-3:2015 Miniature fuses - Part 3: Sub-miniature fuse-links
EN 60127-2:2014 Miniature fuses - Part 2: Cartridge fuse-links
IEC 60127-1:2006+AMD1:2011+AMD2:2015 CSV Miniature fuses - Part 1: Definitions for miniature fuses andgeneral requirements for miniature fuse-links
IEC 60695-2-13:2010+AMD1:2014 CSV Fire hazard testing - Part 2-13: Glowing/hot-wire based test methods- Glow-wire ignition temperature (GWIT) test method for materials
EN 60112 : 2003 AMD 1 2009 METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS
IEC 60999-1:1999 Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included)
IEC 60127-2:2014 Miniature fuses - Part 2: Cartridge fuse-links
EN 60695-2-13:2010/A1:2014 FIRE HAZARD TESTING - PART 2-13: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE IGNITION TEMPERATURE (GWIT) TEST METHOD FOR MATERIALS (IEC 60695-2-13:2010/A1:2014)
EN 60068-2-27:2009 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60695-2-12:2010+AMD1:2014 CSV Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods- Glow-wire flammability index (GWFI) test method for materials
ISO 1302:2002 Geometrical Product Specifications (GPS) Indication of surface texture in technical product documentation
IEC 60068-2-47:2005 Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 60364-4-44:2007+AMD1:2015 CSV Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances
EN 60068-2-21:2006 Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
EN 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
IEC 60060-3:1976 High-voltage test techniques - Part 3: Measuring devices
EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
EN 61210:2010 Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements
IEC 60050-826:2004 International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
EN 60999-1:2000 Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm² up to 35 mm² (included)
EN 61140:2016 Protection against electric shock - Common aspects for installation and equipment
EN 60068-3-4:2002 Environmental testing - Part 3-4: Supporting documentation and guidance - Damp heat tests
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-3-4:2001 Environmental testing - Part 3-4: Supporting documentation and guidance - Damp heat tests
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 61140:2016 Protection against electric shock - Common aspects for installation and equipment
EN 60695-11-5:2017 Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance
IEC 60695-11-5:2016 Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance
EN 60695-2-12:2010/A1:2014 FIRE HAZARD TESTING - PART 2-12: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE FLAMMABILITY INDEX (GWFI) TEST METHOD FOR MATERIALS (IEC 60695-2-12:2010/A1:2014)
EN 60068-2-45:1992/A1:1993 Environmental testing - Part 2: Tests - Test Xa and guidance: Immersion in cleaning solvents
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
IEC 60050-581:2008 International Electrotechnical Vocabulary (IEV) - Part 581: Electromechanical components for electronic equipment
IEC 60216-1:2013 Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results
EN 60068-2-47:2005 Environmental testing - Part 2-47: Tests - Mounting of specimens for vibration, impact and similar dynamic tests