BS EN 60118-4:2006
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Electroacoustics. Hearing aids Induction loop systems for hearing aid purposes. Magnetic field strength
Hardcopy , PDF
04-30-2018
English
01-31-2007
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General
5 Using components of a sound system in an induction-loop
system
6 Meters and test signals
7 Magnetic background noise level of the installation site
8 Characteristics to be specified, methods of measurement
and requirements
9 Small-volume systems
10 Setting up (commissioning) the system
Annex A (informative) - Systems for small useful magnetic
field volumes
Annex B (informative) - Measuring equipment
Annex C (informative) - Provision of information
Annex D (informative) - Measuring speech signals
Annex E (informative) - Basic theory and practice of audio-frequency
induction-loop systems
Annex F (informative) - Effects of metal in the building structure
on the magnetic field
Annex G (informative) - Calibration of field-strength meters
Annex H (informative) - Effect of the aspect ratio of the loop on
the magnetic field strength
Annex I (informative) - Overspill of magnetic field from an
induction-loop system
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Defines requirements for the field strength in audio-frequency induction loops for hearing aid purposes, which will give adequate signal-to-noise ratio without overloading the hearing aid.
Committee |
EPL/29
|
DevelopmentNote |
Supersedes 98/230881 DC and BS 6083-4(1981). (05/2005) Supersedes 12/30264220 DC. (02/2015) Redesignated as BS EN 60118-4. (05/2018)
|
DocumentType |
Standard
|
Pages |
44
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Applies to audio-frequency induction loop systems producing an alternating magnetic field at audio frequencies and intended to provide an input signal for hearing aids operating with an induction pick-up coil. The standard specifies requirements for the field strength in audio-frequency induction loops for hearing aid purposes, which will give adequate signal-to-noise ratio without overloading the hearing aid. The standard also specifies the minimum frequency response requirements for acceptable intelligibility. Methods for measuring the magnetic field strength are specified, and information is given on appropriate measuring equipment (see Annex B), information that should be provided to the operator and users of the system (see Annex C), and other important considerations.
Standards | Relationship |
I.S. EN 60118-4:2015 | Identical |
IEC 60118-4:2014+AMD1:2017 CSV | Identical |
NBN EN 60118-4 : 2015 | Identical |
NF EN 60118-4 : 2015 | Identical |
SN EN 60118-4 : 1998 AMD 1 1998 | Identical |
UNE-EN 60118-4:2016 | Identical |
DIN EN 60118-4:2015-10 | Identical |
EN 60118-4:2015 | Identical |
BS 8300:2001 | Design of buildings and their approaches to meet the needs of disabled people. Code of practice |
BS 5839-9:2011 | Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of emergency voice communication systems |
BIP 3043 : 2005 | BS 8300 - DESIGN OF BUILDINGS AND THEIR APPROACHES TO MEET THE NEEDS OF DISABLED PEOPLE - CODE OF PRACTICE |
BS 7594:2011 | Code of practice for audio-frequency induction-loop systems (AFILS) |
BS 8300(2009) : 2009 | DESIGN OF BUILDINGS AND THEIR APPROACHES TO MEET THE NEEDS OF DISABLED PEOPLE - CODE OF PRACTICE |
08/30182649 DC : DRAFT MAY 2008 | BS 8300 - DESIGN OF BUILDINGS AND THEIR APPROACHES TO MEET THE NEEDS OF DISABLED PEOPLE - CODE OF PRACTICE |
17/30335834 DC : 0 | BS 8300-2 - DESIGN OF AN ACCESSIBLE AND INCLUSIVE BUILT ENVIRONMENT - PART 2: BUILDINGS - CODE OF PRACTICE |
BIP 3044 : 2005 | BS 8300 - DESIGN OF BUILDINGS AND THEIR APPROACHES TO MEET THE NEEDS OF DISABLED PEOPLE - CODE OF PRACTICE |
09/30187281 DC : 0 | BS 5839-9 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 9: CODE OF PRACTICE FOR THE DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE OF EMERGENCY VOICE COMMUNICATION SYSTEMS |
HD 483.10 : 200S1 | SOUND SYSTEM EQUIPMENT - PART 10: PEAK PROGRAMME LEVEL METERS |
IEC 62489-1:2010+AMD1:2014 CSV | Electroacoustics - Audio-frequency induction loop systems for assisted hearing - Part 1: Methods of measuring and specifying theperformance of system components |
IEC 60268-3:2013 | Sound system equipment - Part 3: Amplifiers |
IEC 60268-10:1991 | Sound system equipment - Part 10: Peak programme level meters |
EN 61672-1:2013 | Electroacoustics - Sound level meters - Part 1: Specifications |
EN 60268-3:2013 | Sound system equipment - Part 3: Amplifiers |
IEC 61938:2013 | Multimedia systems - Guide to the recommended characteristics of analogue interfaces to achieve interoperability |
IEC 61260-1:2014 | Electroacoustics - Octave-band and fractional-octave-band filters - Part 1: Specifications |
IEC 60268-1:1985 | Sound system equipment. Part 1: General |
TR 101 767 : 1.1.1 | HUMAN FACTORS (HF); SYMBOLS TO IDENTIFY TELECOMMUNICATIONS FACILITIES FOR DEAF AND HARD OF HEARING PEOPLE; DEVELOPMENT AND EVALUATION |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.