BS EN 60079-6:2007
Current
The latest, up-to-date edition.
Explosive atmospheres Equipment protected by oil immersion \'o\'
Hardcopy , PDF
English
06-30-2008
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Constructional requirements
5 Protective Liquid
6 Verifications and tests
7 Marking
8 Instructions
Annex A (normative) - Selection and erection requirements
Annex B (normative) - Maintenance requirements
Annex C (normative) - Repair and Overhaul requirements
Bibliography
Annex ZA (normative) - Normative references to international
Publications with their corresponding
European publications
Annex ZZ (informative) - Relationship between this European
standard and the essential requirements of
Directive 94/9/EC aimed to be covered
Defines the requirements for the design construction testing and marking of Ex Equipment and Ex Components with type of protection liquid immersion 'o' intended for use in explosive gas Atmospheres.
Committee |
EXL/31
|
DevelopmentNote |
Supersedes 05/30128501 DC. (04/2008) Supersedes BS EN 50015. (06/2008) Supersedes 13/30267448 DC. (01/2016)
|
DocumentType |
Standard
|
Pages |
22
|
PublisherName |
British Standards Institution
|
Status |
Current
|
SupersededBy | |
Supersedes |
Standards | Relationship |
UNE-EN 60079-6:2016 | Identical |
NF EN 60079-6 : 2016 | Identical |
NBN EN 60079-6 : 2016 | Identical |
I.S. EN 60079-6:2015 | Identical |
DIN EN 60079-6 : 2016 | Identical |
EN 60079-6:2015 | Identical |
EI Model code of safe practice Part 15:2015 | MODEL CODE OF SAFE PRACTICE - PART 15: AREA CLASSIFICATION FOR INSTALLATIONS HANDLING FLAMMABLE FLUIDS |
09/30205684 DC : 0 | BS 7375 - CODE OF PRACTICE FOR DISTRIBUTION OF ELECTRICITY ON CONSTRUCTION AND BUILDING SITES |
ISO 3016:1994 | Petroleum products Determination of pour point |
ISO 2719:2016 | Determination of flash point — Pensky-Martens closed cup method |
EN 60156:1995 | Insulating liquids - Determination of the breakdown voltage at power frequency - Test method |
IEC 62021-1:2003 | Insulating liquids - Determination of acidity - Part 1: Automatic potentiometric titration |
IEC 61125:1992 | Unused hydrocarbon based insulating liquids - Test methods for evaluating the oxidation stability |
EN ISO 3104:1996 | Petroleum products - Transparent and opaque liquids - Determination of kinematic viscosity and calculation of dynamic viscosity (ISO 3104:1994) |
EN 60079-0:2012/A11:2013 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED) |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
IEC 60156:1995 | Insulating liquids - Determination of the breakdown voltage at power frequency - Test method |
EN 61125:1993/A1:2004 | UNUSED HYDROCARBON-BASED INSULATING LIQUIDS - TEST METHODS FOR EVALUATING THE OXIDATION STABILITY |
EN 61099:2010 | Insulating liquids - Specifications for unused synthetic organic esters for electrical purposes |
IEC 62535:2008 | Insulating liquids - Test method for detection of potentially corrosive sulphur in used and unused insulating oil |
IEC 62770:2013 | Fluids for electrotechnical applications - Unused natural esters for transformers and similar electrical equipment |
IEC 61099:2010 | Insulating liquids - Specifications for unused synthetic organic esters for electrical purposes |
EN 60814:1997 | Insulating liquids - Oil-impregnated paper and pressboard - Determination of water by automatic coulometric Karl Fischer titration |
EN 62770:2014 | Fluids for electrotechnical applications - Unused natural esters for transformers and similar electrical equipment |
EN 62535:2009 | Insulating liquids - Test method for detection of potentially corrosive sulphur in used and unused insulating oil |
IEC 60836:2015 | Specifications for unused silicone insulating liquids for electrotechnical purposes |
IEC 60296:2012 RLV | Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
IEC 60050-421:1990 | International Electrotechnical Vocabulary (IEV) - Part 421: Power transformers and reactors |
EN 60296:2012 | Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 60836:2015 | Specifications for unused silicone insulating liquids for electrotechnical purposes |
EN 60247:2004 | Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor (tan d) and d.c. resistivity |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
IEC 60814:1997 | Insulating liquids - Oil-impregnated paper and pressboard - Determination of water by automatic coulometric Karl Fischer titration |
EN ISO 2719:2016 | Determination of flash point - Pensky-Martens closed cup method (ISO 2719:2016) |
IEC 60247:2004 | Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor (tan d) and d.c. resistivity |
EN ISO 2592:2017 | Petroleum and related products - Determination of flash and fire points - Cleveland open cup method (ISO 2592:2017) |
EN 50495:2010 | Safety devices required for the safe functioning of equipment with respect to explosion risks |
EN 62021-1:2003 | Insulating liquids - Determination of acidity - Part 1: Automatic potentiometric titration |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.