BS EN 60044-7:2000
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Instrument transformers Electronic voltage transformers
Hardcopy , PDF
02-28-2017
English
05-15-2000
1 General
1.1 Scope
1.2 Normative references
1.3 General block diagram of electronic voltage
transformers
2 Definitions
2.1 General definitions
2.2 Additional definitions for single-phase
electronic protective voltage transformers
2.3 Index of symbols
3 General requirements
3.1 General
3.2 Information to be given for enquiries,
tenders and orders
4 Normal and special service conditions
4.1 Normal service conditions
4.2 Special service conditions
4.3 Earthing system
5 Ratings
5.1 Standard values of rated voltages
5.2 Standard values of rated output
5.3 Standard values of rated voltage factor
5.4 Standard values of rated auxiliary power
supply voltage
5.5 Standard reference values of other influencing
parameters
6 Design requirements
6.1 Insulation requirements for primary voltage
sensor
6.2 Insulation requirements for low-voltage
components
6.3 Short-circuit withstand capability
6.4 Limits of temperature rise
6.5 Radio interference voltage requirements
6.6 Transmitted overvoltage requirements
6.7 Electromagnetic compatibility requirements
6.8 Reliability
6.9 Abnormal conditions withstand capability
6.10 Abnormal conditions signalling
6.11 Mechanical requirements
6.12 Earthing terminals
7 Classification of tests
7.1 Type tests
7.2 Routine tests
7.3 Special tests
8 Type tests
8.1 Impulse test on primary voltage terminals
8.2 Wet test for outdoor type electronic voltage
transformers
8.3 Tests for accuracy
8.4 Test for abnormal conditions withstand capability
8.5 Radio interference voltage test
8.6 Transmitted overvoltage test
8.7 Electromagnetic compatibility tests
8.8 Impulse voltage withstand test for low-voltage
components
8.9 Transient performance tests
9 Routine tests
9.1 Verification of terminal markings
9.2 Power-frequency withstand tests on primary
voltage terminals and partial discharge
measurement
9.3 Power-frequency voltage withstand test for
low-voltage components
9.4 Tests for accuracy
10 Special tests
10.1 Chopped lightning-impulse test on primary voltage
terminals
10.2 Measurement of capacitance and dielectric
dissipation factor
10.3 Mechanical strength tests
11 Markings
11.1 Rating plate markings
11.2 Terminal markings
12 Accuracy requirements for single-phase electronic
measuring voltage transformers
12.1 General requirements
12.2 Maintenance requirement
12.3 Accuracy class designation for electronic
measuring voltage transformers
12.4 Standard accuracy classes for electronic
measuring voltage transformers
12.5 Limits of voltage error and phase displacement
for electronic measuring voltage transformers
13 Additional requirements for single-phase electronic
protective voltage transformers
13.1 General requirements
13.2 Maintenance requirements
13.3 Accuracy class designation for electronic
protective voltage transformers
13.4 Standard accuracy classes for electronic
protective voltage transformers
13.5 Limits of voltage error and phase displacement
for electronic protective voltage transformers
13.6 Transient performance requirements
Annex A (normative) Burdens for the transient response test
Annex B (informative) Technical information for electronic
voltage transformers
Annex C (informative) Bibliography
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Applies to newly manufactured electronic voltage transformers with analogue output, intended for use with electrical measuring instruments and electrical protective devices at frequencies between 15 Hz and 100 Hz.
Committee |
PEL/38
|
DevelopmentNote |
Also numbered as IEC 60044-7. Supersedes 93/202657 DC. (09/2005) Superseded by BS EN 61869-6, but remains current and will be withdrawn on 23/12/2019. (03/2017)
|
DocumentType |
Standard
|
Pages |
76
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Applies to newly manufactured electronic voltage transformers with analogue output, for use with electrical measuring instruments and electrical protective devices at frequencies from 15 Hz to 100 Hz. The standard covers optical arrangements with electronic components. Three-phase voltage transformers are not included, but some of the requirements apply.
Standards | Relationship |
I.S. EN 60044-7:2000 | Identical |
NF EN 60044-7 : 2001 | Identical |
DIN EN 60044-7 : 2000 | Identical |
NBN EN 60044-7 : 2001 | Identical |
UNE-EN 60044-7:2001 | Identical |
EN 60044-7:2000 | Identical |
SN EN 60044-7 : 2000 | Identical |
IEC 60060-2:2010 | High-voltage test techniques - Part 2: Measuring systems |
IEC 60255-22-1:2007 | Measuring relays and protection equipment - Part 22-1: Electrical disturbance tests - 1 MHz burst immunity tests |
EN 60044-2:1999/A2:2003 | INSTRUMENT TRANSFORMERS - PART 2: INDUCTIVE VOLTAGE TRANSFORMERS |
IEC 60038:2009 | IEC standard voltages |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 61000-2-10:1998 | Electromagnetic compatibility (EMC) - Part 2-10: Environment - Description of HEMP environment - Conducted disturbance |
EN 60721-3-1:1997 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 1: Storage |
EN 61000-4-1:2007 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
HD 478.2.3 : 200S1 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - ENVIRONMENTAL CONDITIONS APPEARING IN NATURE - AIR PRESSURE |
HD 478.2.2 : 200S1 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - ENVIRONMENTAL CONDITIONS APPEARING IN NATURE - PRECIPITATION AND WIND |
HD 478.2.6 : 200S1 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - ENVIRONMENTAL CONDITIONS APPEARING IN NATURE - EARTHQUAKE VIBRATION AND SHOCK |
IEC TR 61000-1-1:1992 | Electromagnetic compatibility (EMC) - Part 1: General - Section 1: Application and interpretation of fundamental definitions and terms |
IEC 61000-2-12:2003 | Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems |
HD 478.3.4 : 200S1 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES STATIONARY USE AT NON-WEATHERPROTECTED LOCATIONS |
IEC 61000-4-1:2006 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
IEC 61000-2-11:1999 | Electromagnetic compatibility (EMC) - Part 2-11: Environment - Classification of HEMP environments |
IEC 60050-601:1985 | International Electrotechnical Vocabulary (IEV) - Part 601: Generation, transmission and distribution of electricity - General |
EN 61000-4-9:2016 | Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Impulse magnetic field immunity test |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC 60044-2:1997+AMD1:2000+AMD2:2002 CSV | Instrument transformers - Part 2 : Inductive voltage transformers |
EN 60721-3-9:1993/A1:1995 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 3: CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - SECTION 9: MICROCLIMATES INSIDE PRODUCTS |
EN 60721-3-5:1997 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 5: Ground vehicle installations |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 60255-11:2008 | Measuring relays and protection equipment - Part 11: Voltage dips, short interruptions, variations and ripple on auxiliary power supply port |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
EN 60721-3-0:1993 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Introduction |
HD 478.2.1 : 200S1 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - ENVIRONMENTAL CONDITIONS APPEARING IN NATURE - TEMPERATURE AND HUMIDITY |
EN 60721-3-7:1995/A1:1997 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 3: CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - SECTION 7: PORTABLE AND NON-STATIONARY USE |
HD 588.1 : S1 AMD 1 | HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS |
HD 472 S1:1989/AC:2013 | NOMINAL VOLTAGES FOR LOW-VOLTAGE PUBLIC ELECTRICITY SUPPLY SYSTEMS |
EN 60255-6 : 94 AC 95 | ELECTRICAL RELAYS - MEASURING RELAYS AND PROTECTION EQUIPMENT |
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV | Common specifications for high-voltage switchgear and controlgear standards |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
HD 478.3.0 : 200S2 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES. INTRODUCTION |
HD 478.3.7 : 200S1 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES PORTABLE AND NON-STATIONARY USE |
HD 478.2.4 : 200S1 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - ENVIRONMENTAL CONDITIONS APPEARING IN NATURE - SOLAR RADIATION AND TEMPERATURE |
EN 50081-2:1993 | Electromagnetic compatibility - Generic emission standard - Part 2: Industrial environment |
EN 60694:1996/A2:2001 | COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS |
HD 478.3.1 : 200S1 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES. STORAGE |
HD 554 : 200S1 | VOLTAGE TRANSFORMERS |
EN 61000-4-8:2010 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 60617-1:1985 | Graphical symbols for diagrams. Part 1: General information, general index. Cross-reference tables |
EN 61000-4-12:2017 | Electromagnetic compatibility (EMC) - Part 4-12: Testing and measurement techniques - Ring wave immunity test |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60255-5:2000 | Electrical Relays - Part 5: Insulation coordination for measuring relays and protection equipment - Requirements and tests |
IEC 60060-3:1976 | High-voltage test techniques - Part 3: Measuring devices |
EN 60071-1:2006/A1:2010 | INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES |
IEC 60255-6:1988 | Electrical relays - Part 6: Measuring relays and protection equipment |
IEC TR 61000-2-1:1990 | Electromagnetic compatibility (EMC) - Part 2: Environment - Section 1: Description of the environment - Electromagnetic environment for low-frequency conducted disturbances and signalling in public power supply systems |
IEC 60050-321:1986 | International Electrotechnical Vocabulary (IEV) - Part 321: Instrument transformers |
HD 478.2.5 : 200S1 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - ENVIRONMENTAL CONDITIONS APPEARING IN NATURE - DUST, SAND, SALT MIST |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
IEC 60186:1987 | Voltage transformers |
IEC 60060-4:1977 | High-voltage test techniques - Part 4: Application guide for measuring devices |
HD 478.2.7 : 200S1 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - ENVIRONMENTAL CONDITIONS APPEARING IN NATURE - FAUNA AND FLORA |
EN 60721-1:1995/A2:1995 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 1: ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES |
EN 60721-3-2:1997 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 2: Transportation |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
IEC 61000-4-29:2000 | Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests |
EN 60721-3-4:1995/A1:1997 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 3: CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - SECTION 4: STATIONARY USE AT NON-WEATHER-PROTECTED LOCATIONS |
HD 478.1 : 200S2 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES |
HD 478.3.3 : 200S1 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES STATIONARY USE AT WEATHERPROTECTED LOCATIONS |
EN 60721-3-6:1993/A2:1997 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 3: CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - SHIP ENVIRONMENT |
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV | Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests |
EN 61000-4-10:2017 | Electromagnetic compatibility (EMC) - Part 4-10: Testing and measurement techniques - Damped oscillatory magnetic field immunity test |
HD 478.3.6 : 200S1 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES SHIP ENVIRONMENT |
EN 60721-3-3 : 95 AMD 2 97 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - STATIONARY USE AT WEATHER-PROTECTED LOCATIONS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.