BS EN 60034-18-41:2014
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
Rotating electrical machines Partial discharge free electrical insulation systems (Type I) used in rotating electrical machines fed from voltage converters. Qualification and quality control tests
Hardcopy , PDF
11-02-2019
English
06-30-2014
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Machine terminal voltages arising
from converter operation
5 Electrical stresses in the insulation system
of machine windings
6 Types of machine insulation
7 Stress categories for Type I insulation systems
used in converter fed machines
8 Design qualification and type tests for Type I
insulation systems
9 Test equipment
10 Qualification of the design of Type
I insulation systems
11 Type test procedure for Type I
insulation systems
12 Routine tests
13 Analysis, reporting and classification
Annex A (informative) - Derivation of
possible terminal voltages in
service for a converter-fed
machine
Annex B (normative) - Derivation of test
voltages for Type I insulation systems
Annex C (normative) - Derivation of
allowable voltages in service
Bibliography
Annex ZA (normative) - Normative
references to international
publications with their
corresponding European
publications
Specifies criteria for assessing the insulation system of stator/rotor windings which are subjected to voltage-source pulse width-modulation (PMW) drives.
Committee |
PEL/2
|
DevelopmentNote |
Supersedes 10/30238620 DC. (06/2014)
|
DocumentType |
Standard
|
Pages |
46
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
Supersedes |
IEC 60034-18-41:2014 defines criteria for assessing the insulation system of stator/rotor windings which are subjected to voltage-source pulse-width-modulation drives. It applies to stator/rotor windings of single or polyphase AC machines with insulation systems for converter operation. It describes qualification tests and quality control (type and routine) tests on representative samples or on completed machines which verify fitness for operation with voltage source converters.
Standards | Relationship |
IEC 60034-18-41:2014 | Identical |
EN 60034-18-41:2014 | Identical |
EN 60034-18-1:2010 | Rotating electrical machines - Part 18-1: Functional evaluation of insulation systems - General guidelines |
CLC/TS 60034-27:2011 | Rotating electrical machines - Part 27: Off-line partial discharge measurements on the stator winding insulation of rotating electrical machines |
EN 60034-18-21:2013 | Rotating electrical machines - Part 18-21: Functional evaluation of insulation systems - Test procedures for wire-wound windings - Thermal evaluation and classification |
EN 60034-18-31 : 2012 | ROTATING ELECTRICAL MACHINES - PART 18-31: FUNCTIONAL EVALUATION OF INSULATION SYSTEMS - TEST PROCEDURES FOR FORM-WOUND WINDINGS - THERMAL EVALUATION AND CLASSIFICATION OF INSULATION SYSTEMS USED IN ROTATING MACHINES (IEC 60034-18-31:2012) |
IEC TS 60034-27:2006 | Rotating electrical machines - Part 27: Off-line partial discharge measurements on the stator winding insulation of rotating electrical machines |
IEC TS 61934:2011 | Electrical insulating materials and systems - Electrical measurement of partial discharges (PD) under short rise time and repetitive voltage impulses |
IEC TS 60034-18-42:2008 | Rotating electrical machines - Part 18-42: Qualification and acceptance tests for partial discharge resistant electrical insulation systems (Type II) used in rotating electrical machines fed from voltage converters |
IEC TS 61800-8:2010 | Adjustable speed electrical power drive systems - Part 8: Specification of voltage on the power interface |
IEC 60172:2015 | Test procedure for the determination of the temperature index of enamelled and tape wrapped winding wires |
IEC 60034-18-1:2010 | Rotating electrical machines - Part 18-1: Functional evaluation of insulation systems - General guidelines |
IEC TS 60034-25:2014 | Rotating electrical machines - Part 25: AC electrical machines used in power drive systems - Application guide |
EN 60172:2015 | Test procedure for the determination of the temperature index of enamelled and tape wrapped winding wires |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60034-18-21:2012 | Rotating electrical machines - Part 18-21: Functional evaluation of insulation systems - Test procedures for wire-wound windings - Thermal evaluation and classification |
CLC/TS 60034-25:2008 | Rotating electrical machines - Part 25: Guidance for the design and performance of a.c. motors specifically designed for converter supply |
CLC/TS 60034-18-42:2011 | Rotating electrical machines - Part 18-42: Qualification and acceptance tests for partial discharge resistant electrical insulation systems (Type II) used in rotating electrical machines fed from voltage converters |
IEC 60034-18-31:2012 | Rotating electrical machines - Part 18-31: Functional evaluation of insulation systems - Test procedures for form-wound windings - Thermal evaluation and classification of insulation systems used in rotating machines |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |