• Shopping Cart
    There are no items in your cart

BS EN 54-7:2001

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

Fire detection and fire alarm systems Smoke detectors. Point detectors using scattered light, transmitted light or ionization

Available format(s)

Hardcopy , PDF

Withdrawn date

09-28-2018

Superseded by

BS EN 54-7:2018

Language(s)

English

Published date

09-29-2006

US$359.44
Excluding Tax where applicable

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
  4.1 Compliance
  4.2 Individual alarm indication
  4.3 Connection of ancillary devices
  4.4 Monitoring of detachable detectors
  4.5 Manufacturer's adjustments
  4.6 On-site adjustment of response behavior
  4.7 Protection against the ingress of foreign
       bodies
  4.8 Response to slowly developing fires
  4.9 Marking
  4.10 Data
  4.11 Additional requirements for software controlled
       detectors
5 Tests
  5.1 General
  5.2 Repeatability
  5.3 Directional dependence
  5.4 Reproducibility
  5.5 Variation in supply parameters
  5.6 Air movement
  5.7 Dazzling
  5.8 Dry heat (operational)
  5.9 Cold (operational)
  5.10 Damp heat, steady state (operational)
  5.11 Damp heat, steady state (endurance)
  5.12 Sulfur dioxide (SO[2]) corrosion (endurance)
  5.13 Shock (operational)
  5.14 Impact (operational)
  5.15 Vibration, sinusoidal (operational)
  5.16 Vibration, sinusoidal (endurance)
  5.17 Electromagnetic compatibility (EMC), immunity
       tests (operational)
  5.18 Fire sensitivity
Annex A (normative) - Smoke tunnel for response threshold
                         value measurements
Annex B (normative) - Test aerosol for response threshold
                         value measurements
Annex C (normative) - Smoke measuring instruments
Annex D (normative) - Apparatus for dazzling test
Annex E (informative) - Apparatus for impact test
Annex F (informative) - Fire test room
Annex G (normative) - Smouldering (pyrolysis) wood fire
                         (TF2)
Annex H (normative) - Glowing smouldering cotton fire
                         (TF3)
Annex I (normative) - Flaming plastics (polyurethane)
                         fire (TF4)
Annex J (normative) - Flaming liquid (n-heptane) fire
                         (TF5)
Annex K (informative) - Information concerning the
                         construction of the smoke tunnel
Annex L (informative) - Information concerning the
                         requirements for the
                         response to slowly
                         developing fires
Annex M (informative) - Information concerning the
                         construction of the
                         measuring ionization chamber
Annex N (normative) - Additional requirements and test
                         methods for smoke detectors
                         with more than one smoke sensor
Annex ZA (informative) - Clauses of this European Standard
                         addressing essential requirements
                         or other provisions of EU Directives
Bibliography

Deals in requirements, test methods and performance criteria for point smoke detectors that operate using scattered light, transmitted light or ionization, for use in fire detection and fire alarm systems for buildings.

Committee
FSH/12
DevelopmentNote
Supersedes BS 5445-7(1984), BS 5445-9(1984), 94/409058 DC & 01/541339 DC. (03/2003) Reviewed and confirmed by BSI, April 2007. (03/2007) Supersedes 03/118985 DC. (09/2007)
DocumentType
Standard
Pages
68
PublisherName
British Standards Institution
Status
Withdrawn
SupersededBy
Supersedes

The amendment will consist of a normative annex that gives requirements for detectors with more than one smoke sensor (these are not included in WI 00072045).

03/119007 DC : DRAFT DEC 2003 BS 5839-6 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 6: CODE OF PRACTICE FOR THE DESIGN, INSTALLATION AND MAINTENANCE OF FIRE DETECTION AND FIRE ALARM SYSTEMS IN DWELLINGS
BS DD9999(2005) : 2005 CODE OF PRACTICE FOR FIRE SAFETY IN THE DESIGN, CONSTRUCTION AND USE OF BUILDINGS
BS 5839-6:2013 Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of fire detection and fire alarm systems in domestic premises
BS 5839-1(2002) : 2002 FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR SYSTEM DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE
BS 9999:2008 Code of practice for fire safety in the design, management and use of buildings
BS 5839-1:2017 Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises
12/30260278 DC : 0 BS 5839-1 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE
12/30258581 DC : 0 BS 5908-2 - FIRE AND EXPLOSION PRECAUTIONS AT PREMISES HANDLING FLAMMABLE GASES, LIQUIDS AND DUSTS - PART 2: GUIDE TO APPLICABLE STANDARDS AND REGULATIONS
BS 6266:2002 Code of practice for fire protection for electronic equipment installations
BS 5839-1:2013 Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises
EEMUA 138 : 2010 DESIGN AND INSTALLATION OF ON-LINE ANALYSER SYSTEMS
16/30314117 DC : 0 BS 9999 - FIRE SAFETY IN THE DESIGN, MANAGEMENT AND USE OF BUILDINGS - CODE OF PRACTICE
01/540647 DC : DRAFT MAY 2001 BS 5839-1 - FIRE DETECTION AND ALARM SYSTEMS FOR BUILDINGS - PART 1 - CODE OF PRACTICE FOR SYSTEM DESIGN, INSTALLATION AND MAINTENANCE
DEFSTAN 02-603/2(2001) : INTERIM REQUIREMENTS FOR THE POLICY, DESIGN AND INSTALLATION OF FIRE DETECTION SYSTEMS IN SHIPS
PD 6686:2006 Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries
BS 5908-2:2012 Fire and explosion precautions at premises handling flammable gases, liquids and dusts Guide to applicable standards and regulations
12/30260280 DC : 0 BS 5839-6 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 6: CODE OF PRACTICE FOR THE DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE OF FIRE DETECTION AND FIRE ALARM SYSTEMS IN DOMESTIC PREMISES
PD 7974-4:2003 Application of fire safety engineering principles to the design of buildings Detection of fire and activation of fire protection systems. (Sub-system 4)
BS 5839-6:2004 Fire detection and fire alarm systems for buildings Code of practice for the design, installation and maintenance of fire detection and fire alarm systems in dwellings

ISO 209-1:1989 Wrought aluminium and aluminium alloys Chemical composition and forms of products Part 1: Chemical composition
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
89/106/EEC : 1988 COUNCIL DIRECTIVE OF 21 DECEMBER 1988 ON THE APPROXIMATION OF LAWS, REGULATIONS AND ADMINISTRATIVE PROVISIONS OF THE MEMBER STATES RELATING TO CONSTRUCTION PRODUCTS
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
EN 60068-2-27:2009 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
HD 323.2.3 : 200S2 BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST CA - DAMP HEAT, STEADY STATE
IEC 60068-2-3:1969 Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
ISO 9001:2015 Quality management systems — Requirements
IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction
HD 323.2.56 : 200S1 BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - DAMP HEAT, STEADY STATE, PRIMARILY FOR EQUIPMENT
IEC 60068-2-56:1988 Environmental testing - Part 2: Tests. Test Cb: Damp heat, steady state, primarily for equipment

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.