BS EN 54-13:2017
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Fire detection and fire alarm systems Compatibility and connectability assessment of system components
Hardcopy , PDF
02-05-2020
English
02-28-2017
European foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Requirements
5 Assessment methods and tests
Annex A (informative) - Example of levels used
in FDAS
Annex B (informative) - Classification of functions
of the FDAS
Annex C (informative) - Example methodology for
theoretical analysis
Annex D (normative) - Software design documentation
Annex E (informative) - Flowchart for assessment of
compatibility/connectability
Defines the requirements for compatibility and connectability assessment of components of fire detection and fire alarm system or voice alarm system as a subsystem of fire detection and fire alarm system.
Committee |
FSH/12/3
|
DevelopmentNote |
Supersedes 96/542173 DC. (09/2005) Supersedes 14/30290848 DC. (02/2017)
|
DocumentType |
Standard
|
Pages |
36
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This European Standard specifies the requirements for compatibility and connectability assessment of components of fire detection and fire alarm systems (including voice alarm systems as a subsystem of fire detection and fire alarm system). The components conform to either with the requirements of EN54 or with a manufacturer’s specification where there is no EN54 standard. The requirements for the transmission path used for a distributed function are covered by the relevant EN54 standard and not by this document. This document also specifies requirements for the integrity of the fire detection and fire alarm system when connected to other systems. This document does not specify the manner in which the system is designed, installed and used in any particular application. This document recognizes that it is not practical to assess the compatibility or connectability of components in all possible configurations. Methods of assessment are specified to reach an acceptable degree of confidence within pre-determined operational and environmental conditions. This document specifies requirements related to compatibility and connectability assessment methods and tests for the components belonging to FDAS or connecting FDAS. This document does not cover components or functions which are not included in a FDAS like functions achieved by a building management system. This document is applicable to systems where the components are interconnected by electrical wires or optical fibre or by radio frequency links or by any combination. For other interconnection technology between components this standard may be used as a guidance. NOTE Other European Standards are expected to cover the requirements of the other systems which may be connected to the fire detection and fire alarm system.
Standards | Relationship |
SN EN 54-13 : 2017 | Identical |
NBN EN 54-13 : 2005 | Identical |
NEN EN 54-13 : 2017 | Identical |
DIN EN 54-13:2014-09 (Draft) | Identical |
ONORM EN 54-13 : 2017 | Identical |
UNE-EN 54-13:2006 | Identical |
NF EN 54-13 : 2017 | Identical |
I.S. EN 54-13:2017 | Identical |
NS EN 54-13 : 2017 | Identical |
EN 54-13:2017 | Identical |
UNI EN 54-13 : 2005 | Identical |
BS 5839-1:2017 | Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises |
PD 6686:2006 | Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries |
BS 5839-1:2013 | Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises |
01/540647 DC : DRAFT MAY 2001 | BS 5839-1 - FIRE DETECTION AND ALARM SYSTEMS FOR BUILDINGS - PART 1 - CODE OF PRACTICE FOR SYSTEM DESIGN, INSTALLATION AND MAINTENANCE |
EN 54-16:2008 | Fire detection and fire alarm systems - Part 16: Voice alarm control and indicating equipment |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
EN 54-1:2011 | Fire detection and fire alarm systems - Part 1: Introduction |
EN 50130-5:2011 | ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.