BS EN 50525-2-41:2011
Current
The latest, up-to-date edition.
Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Single core cables with crosslinked silicone rubber insulation
Hardcopy , PDF
English
09-30-2011
1 Scope
2 Normative references
3 Terms and definitions
4 Heat resistant cables (180 degree C)
Annex A (normative) - Tests for cables to EN 50525-2-41
Annex B (normative) - General data
Annex C (normative) - Requirements for compatibility test
National Annex (informative) - Origins and identification
of the particular cable types
Bibliography
Pertains to cross-linked silicone rubber insulated single core cables.
Committee |
GEL/20/17
|
DevelopmentNote |
Together with BS EN 50525-1 & 2-42, supersedes BS 6007(2006). To be read in conjunction with BS EN 50525-1. Supersedes 08/30188796 DC. (10/2011)
|
DocumentType |
Standard
|
Pages |
18
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
EN50525-2-41 applies to cross-linked silicone rubber insulated single core cables. The types included are either insulated only, or insulated and braided, or insulated and sheathed.
The cables are of rated voltages U0/U up to and including 300/500V.
The cables are intended for use in fixed installations within high temperature zones.
The maximum conductor operating temperature for each of the cables in this standard is 180C.
NOTE HD 516 contains extensive guidance on the safe use of cables in this standard.
This EN50525-2-41 should be read in conjunction with EN50525-1, which specifies general requirements.
Standards | Relationship |
IEC 60601-2-8:2010/AMD1:2015 | Identical |
EN 50525-2-41:2011 | Identical |
EN 60719:1993 | Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V |
IEC 60228:2004 | Conductors of insulated cables |
EN 60228:2005 COR 2005 | CONDUCTORS OF INSULATED CABLES |
EN 60332-1-2:2004/A11:2016 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015) |
IEC 60332-1-2:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
EN 50525-1:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 1: General requirements |
IEC 60811-1-2:1985 | Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Two: Thermal ageing methods |
EN 60811-1-2:1995/A2:2000 | INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - THERMAL AGEING METHODS |
HD 516 S2:1997/A2:2008 | GUIDE TO USE OF LOW VOLTAGE HARMONIZED CABLES |
EN 50395 : 2005 AMD 1 2011 | ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
EN 50363-1:2005 | Insulating, sheathing and covering materials for low voltage energy cables - Part 1: Cross-linked elastomeric insulating compounds |
IEC 60811-1-4:1985 | Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature |
EN 50363-2-1 : 2005 AMD 1 2011 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 2-1: CROSS-LINKED ELASTOMERIC SHEATHING COMPOUNDS |
EN 50396 : 2005 AMD 1 2011 | NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
EN 60811-1-4:1995/A2:2001 | INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-4: GENERAL APPLICATION - TESTS AT LOW TEMPERATURE |