BS EN 50463-2:2017
Current
The latest, up-to-date edition.
Railway applications. Energy measurement on board trains Energy measuring
Hardcopy , PDF
English
11-06-2018
European foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions, abbreviations and symbols
4 Requirements
5 Conformity assessment
Annex A (normative) - Test with magnetic induction
of external origin
Annex B (normative) - EMF Configurations
Annex C (informative) - Expressing EMF accuracy
Annex D (informative) - Recommendations for re-verification
and defining of its regime
Annex E (informative) - Durability test
Annex ZZ (informative) - Relationship between this European
Standard and the Essential Requirements of Directive
2008/57/EC
Bibliography
Defines the requirements applicable to the Energy Measurement Function (EMF) of an Energy Measurement System (EMS) for use on board traction units for measurement of energy supplied directly from/to the Contact Line system.
Committee |
GEL/9
|
DevelopmentNote |
Together with BS EN 50463-1, -3, -4 & -5, it supersedes BS EN 50463. Supersedes 11/30213786 DC. (01/2013) Supersedes 15/30329546 DC. (10/2017)
|
DocumentType |
Standard
|
ISBN |
9780539027754
|
Pages |
98
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard covers the requirements applicable to the Energy Measurement Function (EMF) of an Energy Measurement System (EMS) for use on board traction units for measurement of energy supplied directly from/to the Contact Line system.
This European Standard also gives requirements for the Current Measurement Function (e.g. current sensor), the Voltage Measurement Function (e.g. voltage sensor) and the Energy Calculation Function (e.g. energy meter).
The Conformity Assessment arrangements for the Voltage Measurement Function, Current Measurement Function, the Energy Calculation Function and a complete Energy Measurement Function are also specified in this document.
The standard has been developed taking into account that in some applications the EMF can be subjected to legal metrological control. All relevant metrological aspects are covered in this part.
Figure 2 shows the flow between the functional blocks of the EMF. Only connections between the functional blocks required by this standard are displayed.
Standards | Relationship |
EN 50463-2:2017/AC:2018-10 | Identical |
EN 50463-2:2017 | Identical |
EN 62059-32-1:2012 | Electricity metering equipment - Dependability - Part 32-1: Durability - Testing of the stability of metrological characteristics by applying elevated temperature |
IEC 60028:1925 | International standard of resistance for copper |
IEC 61869-3:2011 | Instrument transformers - Part 3: Additional requirements for inductive voltage transformers |
IEC 61373:2010 | Railway applications - Rolling stock equipment - Shock and vibration tests |
EN 60077-4:2003 | Railway applications - Electric equipment for rolling stock - Part 4: Electrotechnical components - Rules for AC circuit-breakers |
EN 50463-3:2017 | Railway applications - Energy measurement on board trains - Part 3: Data handling |
EN 60359:2002 | Electrical and electronic measurement equipment - Expression of performance |
EN 50463-4:2017 | Railway applications - Energy measurement on board trains - Part 4: Communication |
IEC 60044-8:2002 | Instrument transformers - Part 8: Electronic current transformers |
EN 60085:2008 | Electrical insulation - Thermal evaluation and designation |
EN 50121-3-2:2016 | Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 50123-1:2003 | Railway applications - Fixed installations - D.C. switchgear - Part 1: General |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 61373:2010/AC:2017-09 | RAILWAY APPLICATIONS - ROLLING STOCK EQUIPMENT - SHOCK AND VIBRATION TESTS (IEC 61373:2010) |
EN 50121-1:2017 | Railway applications - Electromagnetic compatibility - Part 1: General |
EN 61869-3 : 2011 | INSTRUMENT TRANSFORMERS - PART 3: ADDITIONAL REQUIREMENTS FOR INDUCTIVE VOLTAGE TRANSFORMERS (IEC 61869-3:2011) |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
EN 50463-5:2017 | Railway applications - Energy measurement on board trains - Part 5: Conformity assessment |
EN 60044-8:2002 | Instrument transformers - Part 8: Electronic current transformers |
EN 50124-1:2017 | Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment |
EN 50125-1:2014 | Railway applications - Environmental conditions for equipment - Part 1: Rolling stock and on-board equipment |
EN 50155:2017 | Railway applications - Rolling stock - Electronic equipment |
IEC 60121:1960 | Recommendation for commercial annealed aluminium electrical conductor wire |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 45545-2:2013+A1:2015 | Railway applications - Fire protection on railway vehicles - Part 2: Requirements for fire behaviour of materials and components |
EN 50163 : 2004 COR 2013 | RAILWAY APPLICATIONS - SUPPLY VOLTAGES OF TRACTION SYSTEMS |
IEC 60359:2001 | Electrical and electronic measurement equipment - Expression of performance |
EN 50388 : 2012 COR 2013 | RAILWAY APPLICATIONS - POWER SUPPLY AND ROLLING STOCK - TECHNICAL CRITERIA FOR THE COORDINATION BETWEEN POWER SUPPLY (SUBSTATION) AND ROLLING STOCK TO ACHIEVE INTEROPERABILITY |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
EN 45545-5:2013+A1:2015 | Railway applications - Fire protection on railway vehicles - Part 5: Fire safety requirements for electrical equipment including that of trolley buses, track guided buses and magnetic levitation vehicles |
IEC 62059-32-1:2011 | Electricity metering equipment - Dependability - Part 32-1: Durability - Testing of the stability of metrological characteristics by applying elevated temperature |
EN 50463-1:2017 | Railway applications - Energy measurement on board trains - Part 1: General |
IEC 60077-4:2003 | Railway applications - Electric equipment for rolling stock - Part 4: Electrotechnical components - Rules for AC circuit-breakers |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-