BS EN 50441-4:2012
Current
The latest, up-to-date edition.
Cables for indoor residential telecommunication installations Cables up to 1 200 MHz. Grade 3
Hardcopy , PDF
English
03-31-2012
Foreword
1 Scope
2 Normative references
3 Quality control
4 Cable construction
5 Mechanical requirements
6 Environmental and climatic requirements
7 Electrical requirements
Bibliography
Defines the constructional details and performance requirements for cables for installation in indoor residential cabling systems characterized up to 1200 MHz.
Committee |
EPL/46
|
DevelopmentNote |
Supersedes 10/30215871 DC. (03/2012)
|
DocumentType |
Standard
|
Pages |
20
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard specifies the constructional details and performance requirements for cables for installation in indoor residential cabling systems characterized up to 1 200 MHz. Cables in this European Standard are based on the common design rules specified in EN 50290 2 1 and are specifically intended for supporting ICT and BCT applications (telephone, computer and TV services) as specified in EN 50173-4. The cables covered in this European Standard are intended to operate with voltages and currents normally encountered in communication systems. These cables are not intended to be used in conjunction with low impedance sources, for example, the electrical power supply of public utility mains. Cables covered in this European Standard may however be subjected to voltages of not more than 300 V a.c or 450 V d.c and comply with the requirements of the Low Voltage Directive. The maximum current rating per conductor is 3 A/mm² unless otherwise specified in the relevant detail specification.
Standards | Relationship |
EN 50441-4:2012 | Identical |
EN 50289-3-9:2001 | Communication cables - Specifications for test methods - Part 3-9: Mechanical test methods - Bending tests |
EN 50289-1-10:2001 | Communication cables - Specifications for test methods - Part 1-10: Electrical test methods - Crosstalk |
IEC 60304:1982 | Standard colours for insulation for low-frequency cables and wires |
EN 50289-1-6:2002 | Communication cables - Specifications for test methods - Part 1-6: Electrical test methods - Electromagnetic performance |
EN 50290-2-27 : 2002 COR 2010 | COMMUNICATION CABLES - PART 2-27: COMMON DESIGN RULES AND CONSTRUCTION - HALOGEN FREE FLAME RETARDANT THERMOPLASTIC SHEATHING COMPOUNDS |
IEC 60794-1-2:2017 | Optical fibre cables - Part 1-2: Generic specification - Basic optical cable test procedures - General guidance |
EN 50289-1-2:2001 | Communication cables - Specifications for test methods - Part 1-2: Electrical test methods - DC resistance |
EN 50289-3-17:2002 | Communication cables - Specifications for test methods - Part 3-17: Mechanical test methods - Adhesion of dielectric and sheath |
EN 60332-1-2:2004/A11:2016 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015) |
EN 50290-2-1:2005 | Communication cables - Part 2-1: Common design rules and construction |
EN 50290-2-23:2013 | COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR MULTI-PAIR CABLES USED IN ACCESS TELECOMMUNICATION NETWORKS: OUTDOOR CABLES |
IEC 60332-1-2:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
EN 50289-1-9:2017 | Communication cables - Specifications for test methods - Part 1-9: Electrical test methods - Unbalance attenuation (transverse conversion loss TCL transverse conversion transfer loss TCTL) |
EN 50173-1:2011 | Information technology - Generic cabling systems - Part 1: General requirements |
EN 50289-1-3:2001 | Communication cables - Specifications for test methods - Part 1-3: Electrical test methods - Dielectric strength |
EN 50289-1-4:2001 | Communication cables - Specifications for test methods - Part 1-4: Electrical test methods - Insulation resistance |
EN 50289-1-8:2017 | Communication cables - Specifications for test methods - Part 1-8: Electrical test methods - Attenuation |
EN 60794-1-2:2017/AC:2017-07 | OPTICAL FIBRE CABLES - PART 1-2: GENERIC SPECIFICATION - BASIC OPTICAL CABLE TEST PROCEDURES - GENERAL GUIDANCE (IEC 60794-1-2:2017) |
HD 402 : 200S2 | STANDARD COLOURS FOR INSULATION FOR LOW-FREQUENCY CABLES AND WIRES |
IEC 60811-1-1:1993+AMD1:2001 CSV | Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties |
EN 50289-1-7:2001 | Communication cables - Specifications for test methods - Part 1-7: Electrical test methods - Velocity of propagation |
EN 50289-1-11:2016 | Communication cables - Specifications for test methods - Part 1-11: Electrical test methods - Characteristic impedance, input impedance, return loss |
EN 50290-2-22 : 2001 AMD 1 2007 | COMMUNICATION CABLES - PART 2-22: COMMON DESIGN RULES AND CONSTRUCTION - PVC SHEATHING COMPOUNDS |
EN 50289-3-7:2001 | Communication cables - Specifications for test methods - Part 3-7: Mechanical test methods - Abrasion resistance of the cable sheath |
EN 50173-4 : 2007 AMD 2 2012 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 4: HOMES |
EN 60811-1-1:1995/A1:2001 | INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING MECHANICAL PROPERTIES |