BS EN 50272-1:2010
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Safety requirements for secondary batteries and battery installations General safety information
Hardcopy , PDF
05-25-2018
English
02-28-2011
1 Scope
2 Normative references
3 Terms and definitions
4 General Information
5 Protection against electric shock
6 Disconnection and separation
7 Commissioning and putting batteries into operation
8 Limit values and correction factors
9 Provisions against explosion hazards
10 Provision against electrolyte hazards
11 Marking, labeling and instructions
12 Transport and storage
13 Disposal and environmental aspects
Bibliography
Gives requirements regarding safety, reliability, life expectancy, mechanical strength, cycle stability, internal resistance, and battery temperature, are determined by various applications, and this, in turn, determines the selection of the battery design and technology.
Committee |
PEL/21
|
DevelopmentNote |
Supersedes BS 6132(1983), BS 6133(1995) & 05/30141652 DC. (02/2012)
|
DocumentType |
Standard
|
Pages |
20
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This European Standard is Part 1 of EN 50272 under the generic title “Safety requirements for secondary batteries and battery installations” with nominal voltages up to DC 1 500 V (low voltage directive) and specifies the basic requirements referred to in the other parts of the standard as follows:
- Part 2 | Stationary batteries |
- Part 3 | Traction batteries |
- Part 4 | Batteries for use in portable appliances |
The requirements regarding safety, reliability, life expectancy, mechanical strength, cycle stability, internal resistance, and battery temperature, are determined by various applications, and this, in turn, determines the selection of the battery design and technology.
In general, the requirements and definitions are specified for lead-acid and nickel-cadmium batteries. For other battery systems, the requirements may be applied accordingly.
The standard covers safety aspects taking into account hazards associated with:
electricity (installation, charging, discharging, etc.);
electrolyte;
inflammable gas mixtures;
storage and transportation.
With respect to electrical safety, reference is made to EN 60364-4-41.
Standards | Relationship |
EN 50272-1:2010 | Identical |
BS 9999:2017 | Fire safety in the design, management and use of buildings. Code of practice |
13/30286749 DC : 0 | BS 8591 - REMOTE CENTRES RECEIVING SIGNALS FROM ALARM SYSTEMS - CODE OF PRACTICE |
BS 8591:2014 | Remote centres receiving signals from alarm systems. Code of practice |
EI Model code of safe practice Part 15:2015 | MODEL CODE OF SAFE PRACTICE - PART 15: AREA CLASSIFICATION FOR INSTALLATIONS HANDLING FLAMMABLE FLUIDS |
IEC 62281:2016 | Safety of primary and secondary lithium cells and batteries during transport |
IEC 62259:2003 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Nickel-cadmium prismatic secondary single cells with partial gas recombination |
IEC 60896-11:2002 | Stationary lead-acid batteries - Part 11: Vented types - General requirements and methods of tests |
EN 61427:2005 | Secondary cells and batteries for photovoltaic energy systems (PVES) - General requirements and methods of test |
IEC 61427:2005 | Secondary cells and batteries for photovoltaic energy systems (PVES) - General requirements and methods of test |
EN 50272-4:2007 | Safety requirements for secondary batteries and battery installations - Part 4: Batteries for use in portable appliances |
IEC 61960:2011 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary lithium cells and batteries for portable applications |
IEC 61982-1:2006 | Secondary batteries for the propulsion of electric road vehicles - Part 1: Test parameters |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
EN 60623:2017 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells |
IEC TR 61438:1996 | Possible safety and health hazards in the use of alkaline secondary cells and batteries - Guide to equipment manufacturers and users |
EN 62281:2017 | Safety of primary and secondary lithium cells and batteries during transport |
EN 61951-1:2017 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary sealed cells and batteries for portable applications - Part 1: Nickel-cadmium |
EN 60952-1:2013 | AIRCRAFT BATTERIES - PART 1: GENERAL TEST REQUIREMENTS AND PERFORMANCE LEVELS (IEC 60952-1:2013) |
IEC 60896-21:2004 | Stationary lead-acid batteries - Part 21: Valve regulated types - Methods of test |
HD 60364-4-41:2017/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK |
EN 60952-3:2013 | AIRCRAFT BATTERIES - PART 3: PRODUCT SPECIFICATION AND DECLARATION OF DESIGN AND PERFORMANCE (DDP) (IEC 60952-3:2013) |
EN 62259:2004 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Nickel-cadmium prismatic secondary single cells with partial gas recombination |
EN 61056-1:2012 | General purpose lead-acid batteries (valve-regulated types) - Part 1: General requirements, functional characteristics - Methods of test |
IEC 61982-2:2002 | Secondary batteries for the propulsion of electric road vehicles - Part 2: Dynamic discharge performance test and dynamic endurance test |
IEC 60952-3:2013 | Aircraft batteries - Part 3: Product specification and declaration of design and performance (DDP) |
IEC 60050-482:2004 | International Electrotechnical Vocabulary (IEV) - Part 482: Primary and secondary cells and batteries |
EN 61056-2:2012 | General purpose lead-acid batteries (valve-regulated types) - Part 2: Dimensions, terminals and marking |
IEC 61056-2:2012 | General purpose lead-acid batteries (valve-regulated types) - Part 2: Dimensions, terminals and marking |
IEC 60952-2:2013 | Aircraft batteries - Part 2: Design and construction requirements |
IEC TR 62188:2003 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Design and manufacturing recommendations for portable batteries made from sealed secondary cells |
EN 61951-2:2017 | Secondary cells and batteries containing alkaline or other non acid electrolytes - Secondary sealed cells and batteries for portable applications - Part 2: Nickel-metal hydride |
EN 61959:2004 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Mechanical tests for sealed portable secondary cells and batteries |
IEC 61982-3:2001 | Secondary batteries for the propulsion of electric road vehicles - Part 3: Performance and life testing (traffic compatible, urban use vehicles) |
IEC 61951-2:2017 | Secondary cells and batteries containing alkaline or other non acid electrolytes - Secondary sealed cells and batteries for portable applications - Part 2: Nickel-metal hydride |
IEC 61951-1:2017 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary sealed cells and batteries for portable applications - Part 1: Nickel-Cadmium |
IEC 60896-22:2004 | Stationary lead-acid batteries - Part 22: Valve regulated types - Requirements |
EN 60254-2:2008 | Lead-acid traction batteries - Part 2: Dimensions of cells and terminals and marking of polarity on cells |
IEC 61056-1:2012 | General purpose lead-acid batteries (valve-regulated types) - Part 1: General requirements, functional characteristics - Methods of test |
EN 50272-2:2001 | Safety requirements for secondary batteries and battery installations - Part 2: Stationary batteries |
EN 60896-11:2003 | Stationary lead-acid batteries - Part 11: Vented types - General requirements and methods of tests |
EN 61982-3:2001 | Secondary batteries for the propulsion of electric road vehicles - Part 3: Performance and life testing (traffic compatible, urban use vehicles) |
EN 60254-1:2005 | Lead acid traction batteries - Part 1: General requirements and methods of tests |
EN 61960:2011 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary lithium cells and batteries for portable applications |
EN 61429:1996/A11:1998 | MARKING OF SECONDARY CELLS AND BATTERIES WITH THE INTERNATIONAL RECYCLING SYMBOL ISO 7000-1135 AND INDICATIONS REGARDING DIRECTIVES 93/86/EEC AND 91/157/EEC |
EN 60622:2003 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Sealed nickel-cadmium prismatic rechargeable single cells |
EN 61982-1 : 2006 | SECONDARY BATTERIES FOR THE PROPULSION OF ELECTRIC ROAD VEHICLES - PART 1: TEST PARAMETERS |
IEC 60952-1:2013 | Aircraft batteries - Part 1: General test requirements and performance levels |
IEC 61429:1995 | Marking of secondary cells and batteries with the international recycling symbol ISO 7000-1135 |
EN 50342 : 2001 AMD 3 2004 | LEAD-ACID STARTER BATTERIES - GENERAL REQUIREMENTS, METHODS OF TEST AND NUMBERING |
EN 60896-22:2004 | Stationary lead-acid batteries - Part 22: Valve regulated types - Requirements |
IEC 60623:2017 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells |
IEC 61959:2004 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Mechanical tests for sealed portable secondary cells and batteries |
EN 60896-21:2004 | Stationary lead-acid batteries - Part 21: Valve regulated types - Methods of test |
EN 60952-2:2013 | AIRCRAFT BATTERIES - PART 2: DESIGN AND CONSTRUCTION REQUIREMENTS (IEC 60952-2:2013) |
EN 50272-3 : 2002 COR 2003 | SAFETY REQUIREMENTS FOR SECONDARY BATTERIES AND BATTERY INSTALLATIONS - PART 3: TRACTION BATTERIES |
EN 61982-2:2002 | Secondary batteries for the propulsion of electric road vehicles - Part 2: Dynamic discharge performance test and dynamic endurance test |
IEC 60622:2002 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Sealed nickel-cadmium prismatic rechargeable single cells |
EN 62133:2013 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.