BS EN 50164-4:2008
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Lightning protection components (LPC) Requirements for conductor fasteners
Hardcopy , PDF
08-31-2011
English
09-30-2008
1 Scope
2 Normative references
3 Definitions
4 Classification
4.1 According to the material composition
4.2 According to fixing arrangement of the conductor within
the fastener
4.3 According to conductor clamping arrangement
5 Requirements
5.1 General
5.2 Environmental requirements
5.3 Mechanical strength
5.4 Installation instructions
5.5 Marking
6 Tests
6.1 General test conditions
6.2 Test preparation
6.3 Environmental influence test
6.4 Resistance to mechanical effects
6.5 Installation instructions
6.6 Marking test
6.7 Construction
7 Electromagnetic compatibility (EMC)
8 Structure and content of the test report
8.1 Report identification
8.2 Specimen description
8.3 Characterization and condition of the test sample and/or
test assembly
8.4 Conductor
8.5 Standards and references
8.6 Test procedure
8.7 Testing equipment, description
8.8 Measuring instruments description
8.9 Results and parameters recorded
Annex A (normative) Environmental test for metallic fasteners
Annex B (normative) Environmental test for non-metallic conductor
fasteners - Resistance to ultraviolet light
Annex C (normative) Flow chart of tests
Bibliography
Describes requirements and tests for metallic and non-metallic conductor fasteners that are used in conjunction with the air termination system and down conductors.
Committee |
GEL/81
|
DocumentType |
Standard
|
Pages |
22
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
EN 50164-4:2008 | Identical |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
EN 62305-4:2011/AC:2016-11 | Protection against lightning - Part 4: Electrical and electronic systems within structures |
IEC 62305-1:2010 | Protection against lightning - Part 1: General principles |
EN ISO 6988:1994 | Metallic and other non-organic coatings - Sulfur dioxide test with general condensation of moisture (ISO 6988:1985) |
EN 62305-3:2011 | Protection against lightning - Part 3: Physical damage to structures and life hazard |
ISO 4892-4:2013 | Plastics — Methods of exposure to laboratory light sources — Part 4: Open-flame carbon-arc lamps |
ISO 4892-2:2013 | Plastics — Methods of exposure to laboratory light sources — Part 2: Xenon-arc lamps |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
EN ISO 4892-2:2013 | Plastics - Methods of exposure to laboratory light sources - Part 2: Xenon-arc lamps (ISO 4892-2:2013) |
ISO 6988:1985 | Metallic and other non organic coatings Sulfur dioxide test with general condensation of moisture |
IEC 60068-2-52:2017 | Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
IEC 62305-3:2010 | Protection against lightning - Part 3: Physical damage to structures and life hazard |
ISO 6957:1988 | Copper alloys Ammonia test for stress corrosion resistance |