BS EN 50151:2003
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Railway applications. Fixed installations. Electric traction. Special requirements for composite insulators
Hardcopy , PDF
12-31-2016
English
08-31-2010
Introduction
1 Scope
2 Normative references
3 Definitions
4 Characteristics of insulators
5 Design, manufacture and workmanship
6 Testing
7 Verification of compliance
8 Maintenance instructions
9 Identification of the insulator
10 Delivery and packaging
Annex A (informative) - Load time withstand curve
Annex B (informative) - Pendulum impact test
Annex C (informative) - Further reading list
Annex ZZ (informative) - Coverage of Essential
Requirements of EC Directives
Bibliography
Covers characteristics for composite insulators for use in electric traction overhead contact lines for railways and tramways, as defined in EN 50119.
Committee |
GEL/9
|
DocumentType |
Standard
|
Pages |
26
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
This European Standard specifies characteristics for composite insulators for use in electric traction overhead contact lines for railways and tramways, as defined in EN 50119. Specific applications where high torsional loads can occur are outside the scope of this standard and particular tests should be agreed between the supplier and purchaser, to represent the critical loading arrangements.
The provisions contained in this European Standard are for the new construction of electric traction overhead contact lines using insulators or when complete refurbishment of existing lines takes place.
This standard provides the purchaser and manufacturer with a range of tests which are used to evaluate the suitability of an insulator product for a given railway environment. Additional tests may be specified by the client to measure the compliance of the insulator under particular operating conditions.
The standard establishes the product characteristics, the test methods and acceptance criteria.
The object of this European Standard is to stipulate the provisions for the design and provision of the service indicated by the manufacturer to the purchaser or informed buyer for application on the railway infrastructure.
Standards | Relationship |
DIN EN 50151 : 2004 COR 1 2010 | Identical |
EN 50151 : 2003 COR 2010 | Identical |
SN EN 50151 : 2003 | Identical |
I.S. EN 50151:2003 | Identical |
EN 50151:2003 | Identical |
NF EN 50151 : 2004 | Identical |
UNE-EN 50151:2004 | Identical |
NBN EN 50151 : 2005 | Identical |
NEN EN 50151 : 2004 C1 2010 | Identical |
IEC 61467:2008 | Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests |
ANSI C29.1 : 1988 | TEST METHODS FOR ELECTRICAL POWER INSULATORS |
IEC 61109:2008 | Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria |
IEC 60754-1:2011 | Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content |
EN 60707 : 1999 | FLAMMABILITY OF SOLID NON-METALLIC MATERIALS WHEN EXPOSED TO FLAME SOURCES - LIST OF TEST METHODS |
IEC 61952:2008 | Insulators for overhead lines - Composite line post insulators for A.C. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria |
IEC 60707:1999 | Flammability of solid non-metallic materials when exposed to flame sources - List of test methods |
EN 50119 : 2009 AMD 1 2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
IEC 60754-2:2011 | Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity |
EN 50163 : 2004 COR 2013 | RAILWAY APPLICATIONS - SUPPLY VOLTAGES OF TRACTION SYSTEMS |
HD 602 : 200S1 | TEST ON GASES EVOLVED DURING COMBUSTION OF ELECTRIC CABLES - DETERMINATION OF DEGREE OF ACIDITY OF GASES EVOLVED DURING THE COMBUSTION OF MATERIALS TAKEN FROM ELECTRIC CABLES BY MEASURING PH CONDUCTIVITY |
EN 61952:2008 | Insulators for overhead lines - Composite line post insulators for A.C. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.