• Shopping Cart
    There are no items in your cart

BS EN 50050-2:2013

Current

Current

The latest, up-to-date edition.

Electrostatic hand-held spraying equipment. Safety requirements Hand-held spraying equipment for ignitable coating powder

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

03-31-2014

US$283.91
Excluding Tax where applicable

Foreword
0 Introduction
1 Scope
2 Normative references
3 Terms and definitions
5 Tests
6 Information for use
Annex A (normative) - Test for ignition
        protection using a shunt and
        an oscilloscope
Annex B (normative) - Ignition test
        within the gas mixture
Annex C (informative) - Quality assurance
        Systems for electrostatic spraying equipment
Annex D (normative) - Requirements for
        explosion protection and prevention
        for ionisators
Annex ZY (informative) - Significant changes
         between this European Standard and
         EN 50050:2006
Annex ZZ (informative) - Coverage of Essential
         Requirements of EU Directives
Bibliography

Defines the requirements for hand-held or hand-operated electrostatic spraying equipment for ignitable coating powders within a temperature range from 5 degrees C to 40 degrees C to be used in explosive atmospheres generated by their own spray cloud.

Committee
EXL/31/-/1
DevelopmentNote
Together with BS EN 50050-1 and BS EN 50050-3,it supersedes BS EN 50050. Supersedes 11/30248845 DC. (03/2014)
DocumentType
Standard
Pages
34
PublisherName
British Standards Institution
Status
Current
Supersedes

1.1 This European Standard specifies the requirements for hand-held or hand-operated electrostatic spraying equipment for ignitable coating powders within a temperature range from 5 °C to 40 °C to be used in explosive atmospheres generated by their own spray cloud.

This European Standard deals with all electrical hazards significant for the electrostatic spraying of coating powders, which could also contain small quantities of added metal particles, if the work is carried out under conditions recommended by the manufacturer. In particular, this includes ignition hazards resulting from the generated explosive atmosphere. This European Standard specifies the design-related and test requirements for electrostatic spraying equipment of type A-P according to Table 1 of EN 50177:2009.

1.2 With regard to explosion protection and prevention measures, this standard also applies to ionisators with corona charging. Ionisators used together with or under similar conditions as electrostatic spraying equipment for ignitable coating powders are considered to be equipment of group II, category 2D for use in potentially explosive areas of zone 21 or 22. All other parts of ionisators are considered to be equipment of category 3D if they are installed or used in potentially explosive areas of zone 22, see Annex D.

1.3 Electrostatic applicators are considered to be equipment of group II, category 2D for use in potentially explosive areas of zone 21 or 22, which have been generated by the equipment itself. All other parts of hand-held electrostatic spraying equipment are considered to be equipment of category 3D if they are installed or used in potentially explosive areas of zone 22.

1.4 All other significant hazards relevant for applicators (e.g. ejection of powder, mechanical strength, electrical hazards (apart from the electrostatic hazards)), noise, explosion, contract with or inhalation of dangerous substances, ergonomics) are covered by EN 1953.

1.5 This European Standard also gives details regarding quality assurance systems for electrostatic spraying equipment, see Annex C.

1.6 Additional requirements may be applicable to equipment designed for use in food and pharmaceutical industry.

1.7 This European Standard does not apply to

  • zone classification of the areas in and around spray booths [see EN 12981],

  • zone classification of other areas with potentially explosive atmosphere [see EN 60079-10-2],

  • selection, erection and application of other electrical and non-electrical equipment in areas with explosion hazard [see EN 60079-14 and EN 12981],

  • cleaning of spraying areas, see instruction manual of the spray booth,

  • fire prevention and protection, for instance fire hazards due to other sources [see EN 12981],

  • dust hazards [see EN 12981].

Standards Relationship
EN 50050-2:2013 Identical

NFPA 33 : 2018 SPRAY APPLICATION USING FLAMMABLE OR COMBUSTIBLE MATERIALS

EN 1127-1:2011 Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology
EN 1953:2013 Atomising and spraying equipment for coating materials - Safety requirements
ISO/TR 11688-1:1995 Acoustics Recommended practice for the design of low-noise machinery and equipment Part 1: Planning
IEC 61340-4-7:2017 Electrostatics - Part 4-7: Standard test methods for specific applications - Ionization
EN 60079-0:2012/A11:2013 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED)
EN ISO 20344:2011 Personal protective equipment - Test methods for footwear (ISO 20344:2011)
EN 50176:2009 Stationary electrostatic application equipment for ignitable liquid coating material - Safety requirements
IEC 60079-17:2013 Explosive atmospheres - Part 17: Electrical installations inspection and maintenance
EN 13463-1:2009 Non-electrical equipment for use in potentially explosive atmospheres - Part 1: Basic method and requirements
IEC 60204-1:2016 Safety of machinery - Electrical equipment of machines - Part 1: General requirements
EN 60079-10-2:2015 Explosive atmospheres - Part 10-2: Classification of areas - Explosive dust atmospheres
EN 50223:2015 Stationary electrostatic application equipment for ignitable flock material - Safety requirements
ISO 12100:2010 Safety of machinery — General principles for design — Risk assessment and risk reduction
EN 50050-1:2013 Electrostatic hand-held spraying equipment - Safety requirements - Part 1: Hand-held spraying equipment for ignitable liquid coating materials
EN 60079-31:2014 Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"
EN 50177:2009/A1:2012 STATIONARY ELECTROSTATIC APPLICATION EQUIPMENT FOR IGNITABLE COATING POWDERS - SAFETY REQUIREMENTS
PREN 50059 : DRAFT 2011 ELECTROSTATIC HAND-HELD SPRAYING EQUIPMENT - SAFETY REQUIREMENTS - HAND-HELD SPRAYING EQUIPMENT FOR NON-IGNITABLE COATING MATERIALS
IEC 61340-4-1:2003+AMD1:2015 CSV Electrostatics - Part 4-1: Standard test methods for specific applications - Electrical resistance of floor coverings and installed floors
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
EN 50050-3:2013 Electrostatic hand-held spraying equipment - Safety requirements - Part 3: Hand-held spraying equipment for ignitable flock
EN 62061:2005/A2:2015 SAFETY OF MACHINERY - FUNCTIONAL SAFETY OF SAFETY-RELATED ELECTRICAL, ELECTRONIC AND PROGRAMMABLE ELECTRONIC CONTROL SYSTEMS (IEC 62061:2005/A2:2015)
IEC 60079-0:2011 Explosive atmospheres - Part 0: Equipment - General requirements
EN 61340-4-1:2004/A1:2015 ELECTROSTATICS - PART 4-1: STANDARD TEST METHODS FOR SPECIFIC APPLICATIONS - ELECTRICAL RESISTANCE OF FLOOR COVERINGS AND INSTALLED FLOORS (IEC 61340-4-1:2003/A1:2015)
IEC 60079-14:2013 Explosive atmospheres - Part 14: Electrical installations design, selection and erection
EN ISO 12100:2010 Safety of machinery - General principles for design - Risk assessment and risk reduction (ISO 12100:2010)
EN 12981:2005+A1:2009 Coating plants - Spray booths for application of organic powder coating material - Safety requirements
EN 60079-14:2014/AC:2016 EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION (IEC 60079-14:2013/COR1:2016)
IEC 60079-31:2013 Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"
EN ISO 13849-1:2015 Safety of machinery - Safety-related parts of control systems - Part 1: General principles for design (ISO 13849-1:2015)
EN 60079-17:2014 Explosive atmospheres - Part 17: Electrical installations inspection and maintenance
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
IEC 62061:2005+AMD1:2012+AMD2:2015 CSV Safety of machinery - Functional safety of safety-related electrical, electronic and programmable electronic control systems
EN 1149-5:2008 Protective clothing - Electrostatic properties - Part 5: Material performance and design requirements
EN 1081:1998 Resilient floor coverings - Determination of the electrical resistance
EN ISO 11688-1:2009 Acoustics - Recommended practice for the design of low-noise machinery and equipment - Part 1: Planning (ISO/TR 11688-1:1995)
ISO 13849-1:2015 Safety of machinery — Safety-related parts of control systems — Part 1: General principles for design
EN 14462:2015 Surface treatment equipment - Noise test code for surface treatment equipment including its ancillary handling equipment - Accuracy grades 2 and 3
ISO 20344:2011 Personal protective equipment Test methods for footwear
CLC/TR 50404:2003 Electrostatics - Code of practice for the avoidance of hazards due to static electricity
EN 60204-1 : 2006 COR 2010 SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 1: GENERAL REQUIREMENTS

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.