BS EN 45510-2-9:2008
Current
The latest, up-to-date edition.
Guide for procurement of power station equipment Electrical equipment. Cabling systems
Hardcopy , PDF
English
09-30-2008
1 Scope
2 Normative references
3 Definitions
3.1 Organisational terms
3.2 Technical terms
3.3 General terms
4 Brief overall project description
4.1 Role and organisation of purchaser
4.2 Site location
4.3 Equipment task
4.4 Equipment to be purchased
4.5 Control and instrumentation
4.6 Electrical supplies and other services
4.7 Other interfaces
4.8 Project programme
4.9 Equipment identification systems
5 Extent of supply
6 Terminal points
7 Operational requirements
7.1 Operating environment
7.2 Manning levels
7.3 Normal operation
7.4 Operating hours
7.5 Start-up and shut-down
7.6 Abnormal conditions
7.7 Further operational requirements
8 Life expectancy
8.1 Design life
8.2 Components requiring periodic maintenance
9 Performance requirements
9.1 Duty
9.2 Performance
9.3 Equipment margins
9.4 Availability
9.5 Levels of component redundancy
9.6 Further performance requirements
10 Design and fabrication
10.1 Specific equipment features
10.2 Design justification
10.3 Material selection
10.4 Safety
10.5 Interchangeability
10.6 Fabrication methods
11 Maintenance requirements
11.1 Planned maintenance
11.2 Personnel safety
11.3 Requirements for access
11.4 Lifting requirements
11.5 Special tools
11.6 Test equipment
11.7 Spare parts strategy
11.8 Special precautions
12 Tender documentation
12.1 Tender documentation
12.2 Contract documentation
13 Applicable legislation, regulations, standards and
further requirements
13.1 Legislation and regulations
13.2 Standards
13.3 Further requirements
14 Evaluation criteria
14.1 General
14.2 Technical criteria
15 Quality measures
15.1 General
15.2 Approvals procedure
15.3 Inspection requirements
15.4 Non-conformity
16 Site factors
16.1 Access
16.2 Facilities
16.3 Site specific requirements
17 Verification of specified performance
17.1 General
17.2 Works tests
17.3 Tests during installation and commissioning
17.4 Technical criteria for trial run
17.5 Functional and performance tests
Annex A (informative) - Design data (Check list)
Annex B (informative) - Supply data (Check list)
Annex C (informative) - Installation data (Check list)
Bibliography
Provides guidance on writing the technical specification for the procurement of equipment for use in electricity generating stations (power stations).
Committee |
PEL/99
|
DevelopmentNote |
Supersedes 94/712993 DC. (10/2008)
|
DocumentType |
Standard
|
Pages |
54
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This standard gives guidance on writing the technical specification for the procurement of equipment for use in electricity generating stations (power stations). This Guide for procurement is not applicable to equipment for use in the nuclear reactor plant area of nuclear power stations. Other possible applications of such equipment have not been considered in the preparation of this Guide.
This Guide on cabling systems deals with a wide range of activities and may be used for any or all of these activities by selection of the relevant parts e.g.:
provision of support for cable;
laying of cable;
completion of cable ends;
The Guide covers the installation of power cable up to and including 20,8/36 (42) kV and the supply and installation of control and instrumentation cable. The supply of power cable is covered by EN 45510-2-8.
The Guide includes the installation of protective conductor cable for earthing and equipotential bonding up to the main earthing busbar(s), but not the below ground earth-electrode network.
The equipment covered by this Guide is defined by its function rather than design type. Therefore, the guidance to the specification is stated in performance terms rather than being specified by a detailed description of the equipment to be supplied.
This Guide indicates to potential purchasers how their specification should be prepared so that
the equipment type and capacity interfaces correctly with other elements of the systems,
predicted performance is achieved,
ancillary equipment is properly sized,
reliability, availability and safety requirements are achieved,
proper consideration is given to the evaluation process and the quality measures to be applied.
This Guide does not determine the type of specification (e.g. detailed, performance, functional) or the extent of supply for any given contract which is normally decided on the basis of the purchaser\'s project strategy. It does not cover
any commercial, contractual or legal issues which are normally in separate parts of an enquiry,
any allocation of responsibilities which are determined by the contract.
This Guide does not prescribe the arrangement of the documents in the enquiry.
NOTE As a comprehensive European environmental policy is still under preparation, this Guide does not address the environmental implications of the equipment.
Standards | Relationship |
EN 45510-2-9:2008 | Identical |
EN 45510-2-9 : 2008 | Identical |
IEC 61537:2006 | Cable management - Cable tray systems and cable ladder systems |
IEC 60364-5-54:2011 | Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors |
HD 629.2 S2:2006/A1:2008 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 2: CABLES WITH IMPREGNATED PAPER INSULATION |
HD 622 S1:1996/A2:2005 | Power cables having rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV with special fire performance for use in power stations |
HD 627 S1:1996/A2:2005 | MULTICORE AND MULTIPAIR CABLES FOR INSTALLATION ABOVE AND BELOW GROUND |
IEC 60228:2004 | Conductors of insulated cables |
IEC 60702-1:2002+AMD1:2015 CSV | Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 1: Cables |
EN 61238-1:2003 | Compression and mechanical connectors for power cables for rated voltages up to 36 kV (Um = 42 kV) - Part 1: Test methods and requirements |
HD 21-3 : S3 AMD 2 2008 | POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - NON-SHEATHED CABLES FOR FIXED WIRING |
IEC 61442:2005 | Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV) |
EN 60702-1:2002/A1:2015 | MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES (IEC 60702-1:2002/A1:2015) |
IEC 60050-195:1998 | International Electrotechnical Vocabulary (IEV) - Part 195: Earthing and protection against electric shock |
EN 50086-2-4:1994/A1:2001 | SPECIFICATION FOR CONDUIT SYSTEMS FOR CABLE MANAGEMENT - PART 2-4: PARTICULAR REQUIREMENTS FOR CONDUIT SYSTEMS BURIED UNDERGROUND |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
EN 60584-3:2008 | Thermocouples - Part 3: Extension and compensating cables - Tolerances and identification system |
IEC 60364-5-51:2005 | Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules |
IEC 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
HD 60364-4-41:2017/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK |
HD 60364-5-54:2011/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-54: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS |
IEC 60584-3:2007 | Thermocouples - Part 3: Extension and compensating cables - Tolerances and identification system |
HD 637 S1:1999/corrigendum:2005 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. |
IEC 60754-1:2011 | Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content |
EN 60228:2005 COR 2005 | CONDUCTORS OF INSULATED CABLES |
EN ISO 9002:1994/AC:1997 | QUALITY SYSTEMS - SPECIFICATION FOR PRODUCTION AND INSTALLATION |
HD 22.3 S4:2004/A1:2006 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSSLINKED INSULATION - PART 3: HEAT RESISTANT SILICONE RUBBER INSULATED CABLES |
IEC 60050-442:1998 | International Electrotechnical Vocabulary (IEV) - Part 442: Electrical accessories |
HD 22.15 : 200S2 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 15: MULTICORE CABLES INSULATED AND SHEATHED WITH HEAT RESISTANT SILICONE RUBBER |
EN 50386:2010/A1:2013 | BUSHINGS UP TO 1 KV AND FROM 250 A TO 5 KA, FOR LIQUID FILLED TRANSFORMERS |
IEC 61196-3:1998 | Radio frequency cables - Part 3: Sectional specification for coaxial cables for use in local area networks |
HD 60364-5-51:2009/A12:2017 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 5-51: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - COMMON RULES |
ISO 9002:1994 | Quality systems — Model for quality assurance in production, installation and servicing |
EN 45510-2-8:2004 | Guide for procurement of power station equipment - Part 2-8: Electrical equipment - Power cables |
EN 60708:2005/AC:2016-08 | LOW-FREQUENCY CABLES WITH POLYOLEFIN INSULATION AND MOISTURE BARRIER POLYOLEFIN SHEATH |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60754-2:2011 | Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity |
EN 50262 : 1998 AMD 2 2004 | CABLE GLANDS FOR ELECTRICAL INSTALLATIONS |
IEC 61238-1:2003 | Compression and mechanical connectors for power cables for rated voltages up to 30 kV (Um = 36 kV) - Part 1: Test methods and requirements |
EN 61442:2005 | Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 36 kV (Um = 42 kV) |
IEC 60079-14:2013 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
ISO 9001:2015 | Quality management systems — Requirements |
IEC 60050-461:2008 | International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables |
EN 60079-14:2014/AC:2016 | EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION (IEC 60079-14:2013/COR1:2016) |
ISO 9000:2015 | Quality management systems — Fundamentals and vocabulary |
EN 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
IEC 60708:2005 | Low-frequency cables with polyolefin insulation and moisture barrier polyolefin sheath |
HD 586.3 : 200S1 | MINERAL INSULATED CABLES WITH A RATED VOLTAGE NOT EXCEEDING 750 V PART 3: GUIDE TO USE |
HD 22-9 : 200S3 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 9: SINGLE CORE HALOGEN-FREE NON-SHEATHED CABLES FOR FIXED WIRING HAVING LOW EMISSION OF SMOKE |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 50146:2000 | Cable ties for electrical installations |
EN 61537:2007 | Cable management - Cable tray systems and cable ladder systems |
IEC 61545:1996 | Connecting devices - Devices for the connection of aluminium conductors in clamping units of any material and copper conductors in aluminium bodied clamping units |
EN 61196-3:1998 | Radio frequency cables - Part 3: Sectional specification for coaxial cables for local area networks |
EN 45510-2-8 : 2004 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-8: ELECTRICAL EQUIPMENT - POWER CABLES |
EN ISO 9000:2015 | Quality management systems - Fundamentals and vocabulary (ISO 9000:2015) |
IEC 60702-2:2002+AMD1:2015 CSV | Mineral insulated cables and their terminations with a rated voltagenot exceeding 750 V - Part 2: Terminations |
HD 604 S1:1994/A3:2005 | 0.6/1 KV POWER CABLES WITH SPECIAL FIRE PERFORMANCE FOR USE IN POWER STATIONS |
IEC 60981:2004 | Extra heavy-duty electrical rigid steel conduits |
EN 60702-2:2002/A1:2015 | MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 2: TERMINATIONS (IEC 60702-2:2002/A1:2015) |
HD 629.1 S2:2006/A1:2008 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 1: CABLES WITH EXTRUDED INSULATION |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.