BS EN 16314:2013
Current
The latest, up-to-date edition.
Gas meters. Additional functionalities
Hardcopy , PDF
English
07-31-2013
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviated terms
4 General requirements
5 Security
6 Power system
7 Additional Functionalities
8 Marking
9 Documentation
10 Environmental considerations
Annex A (informative) - Download software
Annex B (informative) - Implementation method -
Conformity to the SM-CG Additional
Functionalities
Annex C (normative) - Electronic index
Annex D (normative) - Valve type test plan
Bibliography
Describes the additional requirements and tests for gas meters with a maximum capacity of 40 m[3]/h and a maximum operating pressure of not exceeding 500 mbar, conforming to EN 1359, EN 12261, EN 12480, EN 12405 and EN 14236, which have battery powered devices providing additional functionalities that form part of the gas meter (hereafter referred to as meter) or contained in an Additional Functionality Device (AFD).
Committee |
GSE/25
|
DevelopmentNote |
Supersedes 11/30247615 DC. (07/2013)
|
DocumentType |
Standard
|
Pages |
64
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard specifies the additional requirements and tests for gas meters with a maximum capacity of 40 m3/h and a maximum operating pressure of not exceeding 500 mbar, conforming to EN 1359, EN 12261, EN 12480, EN 12405 and EN 14236, which have battery powered devices providing additional functionalities that form part of the gas meter (hereafter referred to as meter) or contained in an Additional Functionality Device (AFD). It also covers the additional requirements when an electronic index is used rather that a mechanical one. Where the option of an integral valve to the meter is specified, this standard only gives requirements for meters having a maximum capacity not exceeding 10 m3/h.
This European Standard is applicable to first, second and third family gases according to EN 437.
This European Standard specifies the construction requirements for electronic components but communication protocols are dealt within other European Standards, e.g. appropriate parts of EN 13757.
NOTE This European Standard covers connections to auxiliary devices but not the requirements for these devices.
This European Standard applies to AFDs that are installed in locations with vibration and shocks of low significance and in:
closed locations (indoor or outdoor with protection as specified by the manufacturer) with condensing or with non-condensing humidity,
or, if specified by the manufacturer:
open locations (outdoor without any covering) with condensing humidity or with non-condensing humidity,
locations liable to temporary saturation,
and in locations with electromagnetic disturbances corresponding to those likely to be found in residential, commercial buildings or similar buildings.
This European Standard does not cover the changing of metrological software within the meter or the upload/download of metrological software.
This European Standard only covers valves integral to the meter.
Standards | Relationship |
EN 16314:2013 | Identical |
EN 61000-6-1:2007 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments |
EN ISO 4892-3:2016 | Plastics - Methods of exposure to laboratory light sources - Part 3: Fluorescent UV lamps (ISO 4892-3:2016) |
CEN/TR 16061:2010 | Gas meters - Smart Gas Meters |
EN 61000-4-9:2016 | Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Impulse magnetic field immunity test |
ISO 6270-1:1998 | Paints and varnishes Determination of resistance to humidity Part 1: Continuous condensation |
2004/22/EC : 2004 | DIRECTIVE 2004/22/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 31 MARCH 2004 ON MEASURING INSTRUMENTS |
EN 60950-1:2006/A2:2013 | INFORMATION TECHNOLOGY EQUIPMENT - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60950-1:2005/A2:2013, MODIFIED) |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
EN 62056-21:2002 | Electricity metering - Data exchange for meter reading, tariff and load control - Part 21: Direct local data exchange |
EN 13757-5:2015 | Communication systems for meters - Part 5: Wireless M-Bus relaying |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
EN 13757-4:2013 | Communication systems for meters and remote reading of meters - Part 4: Wireless meter readout (Radio meter reading for operation in SRD bands) |
ISO 7724-3:1984 | Paints and varnishes Colorimetry Part 3: Calculation of colour differences |
EN 437:2003+A1:2009 | Test gases - Test pressures - Appliance categories |
EN 55022:2010/AC:2011 | INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008) |
EN 61000-6-2:2005/corrigendum:2005 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005) |
ISO 4892-3:2016 | Plastics — Methods of exposure to laboratory light sources — Part 3: Fluorescent UV lamps |
EN 61000-4-8:2010 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
OIML R 137-1 : 2006 | GAS METERS - PART 1: REQUIREMENTS |
ASTM D 1003 : 2013 : REDLINE | Standard Test Method for Haze and Luminous Transmittance of Transparent Plastics |
EN 60086-1:2015 | Primary batteries - Part 1: General |
EN 1359:2017 | Gas meters - Diaphragm gas meters |
EN 60086-4:2015 | Primary batteries - Part 4: Safety of lithium batteries |
EN 13757-6:2015 | Communication systems for meters - Part 6: Local Bus |
EN ISO 13849-1:2015 | Safety of machinery - Safety-related parts of control systems - Part 1: General principles for design (ISO 13849-1:2015) |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
EN 61010-1:2010 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
CEN Guide 4:2008 | GUIDE FOR ADDRESSING ENVIRONMENTAL ISSUES IN PRODUCT STANDARDS |
IEC 61508-1:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see Functional Safety and IEC 61508) |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 12405-2:2012 | Gas meters - Conversion devices - Part 2: Energy conversion |
EN 13757-1:2014 | Communication systems for meters - Part 1: Data exchange |
ISO 13849-1:2015 | Safety of machinery — Safety-related parts of control systems — Part 1: General principles for design |
EN 14236:2007 | Ultrasonic domestic gas meters |
EN 1776:2015 | Gas infrastructure - Gas measuring systems - Functional requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.