BS EN 14846:2008
Current
The latest, up-to-date edition.
Building hardware. Locks and latches. Electromechanically operated locks and striking plates. Requirements and test methods
Hardcopy , PDF
English
03-31-2009
Foreword
1 Scope
2 Normative references
3 Terms, definitions and symbols
4 Classification
4.1 General
4.2 Classification
4.3 Category of use (first digit)
4.4 Durability and load on latchbolt (second digit)
4.5 Door mass and closing force (third digit)
4.6 Suitability for use on fire/smoke doors (fourth digit)
4.7 Safety (fifth digit)
4.8 Corrosion, temperature and humidity (sixth digit)
4.9 Security (seventh digit)
4.10 Security - electrical function (eighth digit)
4.11 Security - electrical manipulation (ninth digit)
5 Requirements
5.1 General
5.2 Category of use
5.3 Durability
5.4 Door mass and closing force
5.5 Suitability for use on fire/smoke doors
5.6 Safety
5.7 Corrosion, temperature and humidity requirements
5.8 Security requirements
5.9 Security - Electrical function - Status indication
5.10 Security - Electrical manipulation
5.11 Requirements for product information
6 Test methods
6.1 Test procedure
6.2 Category of use tests
6.3 Durability tests
6.4 Door mass and closing force
6.5 Fire/smoke resistance tests
6.6 Safety
6.7 Corrosion, temperature and humidity tests
6.8 Security tests
6.9 Security - Electrical function tests - Status indication
6.10 Security - Electrical manipulation tests
7 Marking
8 Evaluation of conformity
8.1 Initial type test
8.2 Sampling, testing and conformity criteria
8.3 Factory production control
8.4 Periodic testing
8.5 Annual testing
Annex A (normative) - Fire/smoke test requirements
Annex B (normative) - Test sampling and sequencing
Annex C (normative) - Installation and fixing instructions
Annex ZA (normative) - Clauses of this European Standard addressing
the provisions of the EU Construction
Products Directive (89/106/EEC)
Bibliography
Describes requirements and test methods for strength, security, durability and function of electrical and electronic components for all types of electromechanically operated locks and striking plates used on doors, window doors and entrance doors in buildings.
Committee |
B/538/4
|
DevelopmentNote |
Supersedes 03/118296 DC. (03/2009)
|
DocumentType |
Standard
|
Pages |
46
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
Standards | Relationship |
EN 14846:2008 | Identical |
16/30332500 DC : 0 | BS 8214 - TIMBER-BASED FIRE DOOR ASSEMBLIES - CODE OF PRACTICE |
BS 7273-4:2015 | Code of practice for the operation of fire protection measures Actuation of release mechanisms for doors |
BS 8214:2016 | Timber-based fire door assemblies. Code of practice |
06/30133094 DC : DRAFT OCT 2006 | BS 7273-4 - CODE OF PRACTICE FOR THE OPERATION OF FIRE PROTECTION MEASURES - PART 4: ACTUATION OF RELEASE MECHANISMS FOR DOORS |
15/30288999 DC : 0 | BS 7273-4 - CODE OF PRACTICE FOR THE OPERATION OF FIRE PROTECTION MEASURES - PART 4: ACTUATION OF RELEASE MECHANISMS FOR DOORS |
93/68/EEC : 1993 AMD 2 1998 | COUNCIL DIRECTIVE 93/68/EEC OF 22.7.93 AMENDING DIRECTIVES 87/404/EEC, 88/378/EEC, 89/106/EEC, 89/336/EEC, 89/392/EEC, 89/686/EEC, 90/384/EEC, 90/385/EEC, 90/396/EEC, 91/263/EEC, 92/42/EEC AND 73/23/EEC |
EN 1906:2012 | Building hardware - Lever handles and knob furniture - Requirements and test methods |
EN 1125:2008 | Building hardware - Panic exit devices operated by a horizontal bar, for use on escape routes - Requirements and test methods |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
89/106/EEC : 1988 | COUNCIL DIRECTIVE OF 21 DECEMBER 1988 ON THE APPROXIMATION OF LAWS, REGULATIONS AND ADMINISTRATIVE PROVISIONS OF THE MEMBER STATES RELATING TO CONSTRUCTION PRODUCTS |
EN 1303:2015 | Building hardware - Cylinders for locks - Requirements and test methods |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
EN 12209:2016 | Building hardware - Mechanically operated locks and locking plates - Requirements and test methods |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
EN 12320:2012 | Building hardware - Padlocks and padlock fittings - Requirements and test methods |
PREN 13637 : DRAFT 2014 | BUILDING HARDWARE - ELECTRICALLY CONTROLLED EXIT SYSTEMS FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
ISO 9001:2015 | Quality management systems — Requirements |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
EN 60335-1:2012/A13:2017 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED) |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
IEC 61000-4-29:2000 | Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests |
EN 61000-4-29:2000 | Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests |
EN 179:2008 | Building hardware - Emergency exit devices operated by a lever handle or push pad, for use on escape routes - Requirements and test methods |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.