BS EN 14846:2008

Current

Current

The latest, up-to-date edition.

Building hardware. Locks and latches. Electromechanically operated locks and striking plates. Requirements and test methods

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

03-31-2009

US$341.21
Excluding Tax where applicable

Foreword
1 Scope
2 Normative references
3 Terms, definitions and symbols
4 Classification
  4.1 General
  4.2 Classification
  4.3 Category of use (first digit)
  4.4 Durability and load on latchbolt (second digit)
  4.5 Door mass and closing force (third digit)
  4.6 Suitability for use on fire/smoke doors (fourth digit)
  4.7 Safety (fifth digit)
  4.8 Corrosion, temperature and humidity (sixth digit)
  4.9 Security (seventh digit)
  4.10 Security - electrical function (eighth digit)
  4.11 Security - electrical manipulation (ninth digit)
5 Requirements
  5.1 General
  5.2 Category of use
  5.3 Durability
  5.4 Door mass and closing force
  5.5 Suitability for use on fire/smoke doors
  5.6 Safety
  5.7 Corrosion, temperature and humidity requirements
  5.8 Security requirements
  5.9 Security - Electrical function - Status indication
  5.10 Security - Electrical manipulation
  5.11 Requirements for product information
6 Test methods
  6.1 Test procedure
  6.2 Category of use tests
  6.3 Durability tests
  6.4 Door mass and closing force
  6.5 Fire/smoke resistance tests
  6.6 Safety
  6.7 Corrosion, temperature and humidity tests
  6.8 Security tests
  6.9 Security - Electrical function tests - Status indication
  6.10 Security - Electrical manipulation tests
7 Marking
8 Evaluation of conformity
  8.1 Initial type test
  8.2 Sampling, testing and conformity criteria
  8.3 Factory production control
  8.4 Periodic testing
  8.5 Annual testing
Annex A (normative) - Fire/smoke test requirements
Annex B (normative) - Test sampling and sequencing
Annex C (normative) - Installation and fixing instructions
Annex ZA (normative) - Clauses of this European Standard addressing
                       the provisions of the EU Construction
                       Products Directive (89/106/EEC)
Bibliography

Describes requirements and test methods for strength, security, durability and function of electrical and electronic components for all types of electromechanically operated locks and striking plates used on doors, window doors and entrance doors in buildings.

Committee
B/538/4
DevelopmentNote
Supersedes 03/118296 DC. (03/2009)
DocumentType
Standard
Pages
46
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
EN 14846:2008 Identical

16/30332500 DC : 0 BS 8214 - TIMBER-BASED FIRE DOOR ASSEMBLIES - CODE OF PRACTICE
BS 7273-4:2015 Code of practice for the operation of fire protection measures Actuation of release mechanisms for doors
BS 8214:2016 Timber-based fire door assemblies. Code of practice
06/30133094 DC : DRAFT OCT 2006 BS 7273-4 - CODE OF PRACTICE FOR THE OPERATION OF FIRE PROTECTION MEASURES - PART 4: ACTUATION OF RELEASE MECHANISMS FOR DOORS
15/30288999 DC : 0 BS 7273-4 - CODE OF PRACTICE FOR THE OPERATION OF FIRE PROTECTION MEASURES - PART 4: ACTUATION OF RELEASE MECHANISMS FOR DOORS

93/68/EEC : 1993 AMD 2 1998 COUNCIL DIRECTIVE 93/68/EEC OF 22.7.93 AMENDING DIRECTIVES 87/404/EEC, 88/378/EEC, 89/106/EEC, 89/336/EEC, 89/392/EEC, 89/686/EEC, 90/384/EEC, 90/385/EEC, 90/396/EEC, 91/263/EEC, 92/42/EEC AND 73/23/EEC
EN 1906:2012 Building hardware - Lever handles and knob furniture - Requirements and test methods
EN 1125:2008 Building hardware - Panic exit devices operated by a horizontal bar, for use on escape routes - Requirements and test methods
EN 61000-4-11:2004/A1:2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017)
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
89/106/EEC : 1988 COUNCIL DIRECTIVE OF 21 DECEMBER 1988 ON THE APPROXIMATION OF LAWS, REGULATIONS AND ADMINISTRATIVE PROVISIONS OF THE MEMBER STATES RELATING TO CONSTRUCTION PRODUCTS
EN 1303:2015 Building hardware - Cylinders for locks - Requirements and test methods
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
EN 61000-4-2:2009 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
EN 12209:2016 Building hardware - Mechanically operated locks and locking plates - Requirements and test methods
EN 61000-4-3 : 2006 AMD 2 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
EN 12320:2012 Building hardware - Padlocks and padlock fittings - Requirements and test methods
PREN 13637 : DRAFT 2014 BUILDING HARDWARE - ELECTRICALLY CONTROLLED EXIT SYSTEMS FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
ISO 9001:2015 Quality management systems — Requirements
EN 61000-4-4:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012)
EN 60335-1:2012/A13:2017 HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED)
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 61000-4-29:2000 Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
EN 61000-4-29:2000 Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
EN 179:2008 Building hardware - Emergency exit devices operated by a lever handle or push pad, for use on escape routes - Requirements and test methods
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.