BS EN 14782:2006
Current
The latest, up-to-date edition.
Self-supporting metal sheet for roofing, external cladding and internal lining. Product specification and requirements
Hardcopy , PDF
English
02-03-2006
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
4.1 Materials
4.2 Nominal thickness
4.3 Mechanical resistance
4.3.1 General
4.3.2 Resistance of roofing products to
concentrated forces
4.4 Water permeability
4.5 Vapour and air permeability
4.6 Dimensional change
4.7 Dimensional tolerances
4.8 Durability
4.9 External fire performance
4.10 Reaction to fire
4.11 Release of regulated dangerous substances
5 Testing, assessment and sampling methods
5.1 External fire performance for roof covering products
5.1.1 Products deemed to satisfy the requirements for
external fire performance
5.1.2 Products classified without the need for further
testing (CWFT option)
5.1.3 Other products
5.2 Reaction to fire
5.2.1 Products satisfying the requirements for reaction
to fire Class A1 without the need for testing
5.2.2 Products classified without the need for further
testing (CWFT option)
5.2.3 Other products
5.3 Release of regulated dangerous substances
6 Evaluation of conformity
6.1 General
6.2 Initial type testing (ITT)
6.2.1 General
6.2.2 Sampling for ITT
6.3 Factory production control (FPC)
6.3.1 General
6.3.2 General requirements
7 Designation
8 Product marking
Annex A (normative) Multilayer coated steel sheet
A.1 General
A.2 Substrate materials
A.3 Specific requirements
A.3.1 Minimum nominal values of thickness
A.3.2 Bituminous coating specification
A.3.3 Durability
A.4 Freedom from defects
Annex B (normative) Determination of resistance to
concentrated forces
B.1 Principle
B.2 Test spans
B.3 Test sheets
B.4 Test procedure
B.5 Number of tests and analysis of results
B.6 Acceptance criteria
B.7 Test report
Annex C (normative) Mounting and fixing conditions of the
test specimen for reaction to fire testing
C.1 General
C.2 Mounting and fixing conditions
C.2.1 General
C.2.2 General configuration
C.2.3 Securing the overlap vertical joint
C.2.4 Standard assembly - Steel corner flashings
C.2.5 Alternative assembly - Corner flashings and seals
C.2.6 Test arrangement for reaction to fire test
according to EN ISO 11925-2 (Ignitability test)
C.3 Direct and extended application of the fire test
results according to EN 13823
C.3.1 General
C.3.2 Direct application: Systems with only one metal
sheet (single skin system without insulation)
C.3.3 Direct application: Systems with two (profiled or
flat) coated metal sheets (or one cassette plus
one sheet) with an insulation between the two
sheets (double skin system)
C.3.4 Extended application: Other insulated systems -
General methodology
Annex ZA (informative) Clauses of this European Standard
addressing the provisions of the EU
Construction Products Directive
ZA.1 Scope and relevant characteristics
ZA.2 Procedures for the attestation of conformity of
products
ZA.3 CE marking and labelling
Bibliography
Describes the terminology, requirements and test methods for factory made self-supporting metal sheets and tiles (for non-structural applications) delivered in the form of manufactured pieces for roofing and wall cladding and lining.
Committee |
B/542/5
|
DevelopmentNote |
Supersedes 03/115372 DC. (03/2006)
|
DocumentType |
Standard
|
Pages |
44
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard specifies the terminology, requirements and test methods for factory made self-supporting metal sheets and tiles (for non-structural applications) delivered in the form of manufactured pieces for roofing and wall cladding and lining. This standard also covers ceiling (including internal metal sheet) and soffit applications and cassettes (see Figure 1). This standard covers self-supporting copper, zinc, steel, aluminium and stainless steel sheet with or without coatings, e.g. metallic, organic, inorganic or multi-layer (see Annex A). A moisture retaining layer may be present on the reverse side of the product. This standard also includes rules for marking, labelling and evaluation of conformity. This standard does not cover products for structural purposes, i.e. it does not cover products intended to contribute to the global or partial stability of the building structure by providing racking resistance or resistance to permanent static loads (excluding self-weight of the metal sheet). Requirements concerning acoustical and thermal insulation properties are not considered in this standard. This standard does not include calculation or design requirements with regards to the works, installation techniques or the performance of the installed products.
Standards | Relationship |
UNE-EN 14782:2006 | Identical |
NEN EN 14782 : 2006 | Identical |
NF EN 14782 : 2006 | Identical |
UNI EN 14782 : 2006 | Identical |
EN 14782:2006 | Identical |
I.S. EN 14782:2006 | Identical |
NBN EN 14782 : 2006 | Identical |
SN EN 14782 : 2006 | Identical |
NS EN 14782 : 1ED 2006 | Identical |
DIN EN 14782:2015-09 (Draft) | Identical |
DIN EN 14782:2006-03 | Identical |
PD 476-3:2012 | Classification rules for the end-use application of test results arising from BS 476-3, \'Classification and method of test for external fire exposure of roofs\' |
BS 5427(2016) : 2016 | CODE OF PRACTICE FOR THE USE OF PROFILED SHEET FOR ROOF AND WALL CLADDING ON BUILDINGS |
11/30256741 DC : DRAFT DEC 2011 | PD 476-3 - CLASSIFICATION RULES FOR THE END-USE APPLICATION OF TEST RESULTS ARISING FROM BS 476-3:2004 "CLASSIFICATION AND METHOD OF TEST FOR EXTERNAL FIRE EXPOSURE OF ROOFS" |
15/30095322 DC : 0 | BS 5427 - CODE OF PRACTICE FOR THE USE OF PROFILED SHEET FOR ROOF AND WALL CLADDING ON BUILDINGS |
12/30256741 DC : 0 | BS PD 476-33 - CLASSIFICATION RULES FOR THE END-USE APPLICATION OF TEST RESULTS ARISING FROM BS 476-3:2004 - CLASSIFICATION AND METHOD OF TEST FOR EXTERNAL FIRE EXPOSURE OF ROOFS |
EN 10002-1 : 2001 | METALLIC MATERIALS - TENSILE TESTING - PART 1: METHOD OF TEST AT AMBIENT TEMPERATURE |
EN 10169-3:2003 | Continuously organic coated (coil coated) steel flat products - Part 3: Products for building interior applications |
EN 508-3:2008 | Roofing products from metal sheet - Specification for self-supporting products of steel, aluminium or stainless steel sheet - Part 3: Stainless steel |
ENV 10169-2 : 1999 | CONTINUOUSLY ORGANIC COATED (COIL COATED) STEEL FLAT PRODUCTS - PRODUCTS FOR BUILDING EXTERIOR APPLICATIONS |
EN 10169-1:2003 | Continuously organic coated (coil coated) steel flat products - Part 1: General information (definitions, materials, tolerances, test methods) |
EN 506:2008 | Roofing products of metal sheet - Specification for self-supporting products of copper or zinc sheet |
ISO 6270-1:1998 | Paints and varnishes Determination of resistance to humidity Part 1: Continuous condensation |
EN 1427:2015 | Bitumen and bituminous binders - Determination of the softening point - Ring and Ball method |
EN 508-2:2008 | Roofing products from metal sheet - Specification for self-supporting products of steel, aluminium or stainless steel sheet - Part 2: Aluminium |
ISO 11925-2:2010 | Reaction to fire tests Ignitability of products subjected to direct impingement of flame Part 2: Single-flame source test |
EN 13501-5:2016 | Fire classification of construction products and building elements - Part 5: Classification using data from external fire exposure to roofs tests |
EN 1396:2015 | Aluminium and aluminium alloys - Coil coated sheet and strip for general applications - Specifications |
EN 1172:2011 | Copper and copper alloys - Sheet and strip for building purposes |
EN 10327:2004 | Continuously hot-dip coated strip and sheet of low carbon steels for cold forming - Technical delivery conditions |
EN 13823:2010+A1:2014 | Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item |
EN 10326:2004 | Continuously hot-dip coated strip and sheet of structural steels - Technical delivery conditions |
EN ISO 6988:1994 | Metallic and other non-organic coatings - Sulfur dioxide test with general condensation of moisture (ISO 6988:1985) |
EN 13162:2012+A1:2015 | Thermal insulation products for buildings - Factory made mineral wool (MW) products - Specification |
EN 10143:2006 | Continuously hot-dip coated steel sheet and strip - Tolerances on dimensions and shape |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
EN 10204:2004 | Metallic products - Types of inspection documents |
ISO 9001:2015 | Quality management systems — Requirements |
ISO 9227:2017 | Corrosion tests in artificial atmospheres — Salt spray tests |
EN ISO 868:2003 | Plastics and ebonite - Determination of indentation hardness by means of a durometer (Shore hardness) (ISO 868:2003) |
ISO 6988:1985 | Metallic and other non organic coatings Sulfur dioxide test with general condensation of moisture |
EN 508-1:2014 | Roofing and cladding products from metal sheet - Specification for self-supporting of steel, aluminium or stainless steel sheet - Part 1: Steel |
ISO 868:2003 | Plastics and ebonite — Determination of indentation hardness by means of a durometer (Shore hardness) |
EN 10088-1:2014 | Stainless steels - Part 1: List of stainless steels |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.