BS EN 14604:2005
Current
The latest, up-to-date edition.
Smoke alarm devices
Hardcopy , PDF
English
04-30-2009
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
4.1 Compliance
4.2 Individual alarm indicator (optional)
4.3 Mains-on indicator
4.4 Connection of external ancillary devices
4.5 Means of calibration
4.6 User replaceable components
4.7 Normal power source
4.8 Standby power source
4.9 Electrical safety requirements
4.10 Routine test facility
4.11 Terminals for external conductors
4.12 Smoke alarm signals
4.13 Battery removal indication
4.14 Battery connections
4.15 Battery capacity
4.16 Protection against the ingress of foreign bodies
4.17 Additional requirements for software controlled smoke
alarms
4.18 Inter-connectable smoke alarms
4.19 Marking and data
5 Tests
5.1 General
5.2 Repeatability
5.3 Directional dependence
5.4 Initial sensitivity
5.5 Air movement
5.6 Dazzling
5.7 Dry heat
5.8 Cold (operational)
5.9 Damp heat (operational)
5.10 Sulphur dioxide (SO[2]) corrosion
5.11 Impact
5.12 Vibration (operational)
5.13 Vibration (endurance)
5.14 Electromagnetic Compatibility (EMC), immunity tests
(operational)
5.15 Fire sensitivity
5.16 Battery fault warning
5.17 Sound output
5.18 Sounder durability
5.19 Inter-connectable smoke alarms
5.20 Alarm silence facility (optional)
5.21 Variation in supply voltage
5.22 Battery reversal
5.23 Back-up power source
5.24 Electrical safety - assessment and testing to
determine the adequacy of personal protection
against hazardous currents passing through the
human body (electric shock), excessive
temperature and the start and spread of fire
Annex A (normative) - Smoke tunnel for response threshold
value measurements
Annex B (normative) - Test aerosol for response threshold
value measurements
Annex C (normative) - Smoke measuring instruments
C.1 Obscuration meter
C.2 Measuring ionization chamber (MIC)
Annex D (normative) - Apparatus for dazzling test
Annex E (informative) - Apparatus for impact test
Annex F (normative) - Fire test room
Annex G (normative) - Smouldering pyrolysis wood fire (TF2)
G.1 Fuel
G.2 Hotplate
G.3 Arrangement
G.4 Heating rate
G.5 End of test condition
G.6 Test validity criteria
Annex H (normative) - Glowing smouldering cotton fire (TF3)
H.1 Fuel
H.2 Arrangement
H.3 Ignition
H.4 End of test condition
H.5 Test validity criteria
Annex I (normative) - Flaming plastics (polyurethane) fire (TF4)
I.1 Fuel
I.2 Arrangement
I.3 Ignition
I.4 End of test condition
I.5 Test validity criteria
Annex J (normative) - Flaming liquid (n-heptane) fire (TF5)
J.1 Fuel
J.2 Arrangement
J.3 Ignition
J.4 End of test condition
J.5 Test validity criteria
Annex K (informative) - Information concerning the construction
of the smoke tunnel
Annex L (normative) - Alarms suitable for installation in
leisure accommodation vehicles (LAVs)
L.1 Temperature cycle test
Annex M (informative) - Information concerning the construction
of the measuring ionization chamber
Annex ZA (informative) - Clauses addressing the provisions of
the EU Construction Products Directive
(89/106/EEC)
ZA.1 Scope and relevant clauses
ZA.2 Procedures for the attestation of conformity of
smoke alarms covered by this standard
ZA.3 CE Marking and labelling and accompanying
documentation
ZA.4 EC certificate and declaration of conformity
Bibliography
This document specifies requirements, test methods, performance criteria, and manufacturer\'s instructions for smoke alarms that operate using scattered light, transmitted light, or ionization, intended for household or similar residential application. Requirements for smoke alarms suitable for use in leisure accommodation vehicles are also included.
Committee |
FSH/12/2
|
DevelopmentNote |
Supersedes BS 5446-1(2000). (09/2005)
|
DocumentType |
Standard
|
Pages |
72
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This document specifies requirements, test methods, performance criteria, and manufacturer\'s instructions for smoke alarms that operate using scattered light, transmitted light or ionization, intended for household or similar residential application.
This document includes additional requirements for smoke alarms, which are also suitable for use in leisure accommodation vehicles.
For the testing of other types of smoke alarms, or smoke alarms working on different principles, this document should only be used for guidance. AC1 Special features of smoke alarms, such as radio interlinking or special characteristics and developed for specific risks, are not covered by this document. AC1
This document allows, although it does not require, the inclusion within the smoke alarm of facilities for interconnection with other similar smoke alarms and/or accessories, and for alarm silencing. Where such facilities are included, this document specifies applicable requirements.
This document does not cover devices intended for incorporation in systems using separate control and indicating equipment.
NOTE Certain types of smoke alarms contain radioactive materials. The national requirements for radiation protection differ from country to country and they are not specified in this document. Such smoke alarms should, however, comply with the applicable national requirements.
Standards | Relationship |
EN 14604:2005 | Identical |
UNI EN 14604 : 2005 | Identical |
NS EN 14604 : 2005 AC 2008 | Identical |
UNE-EN 14604:2006 | Identical |
NBN EN 14604 : 2005 COR 2008 | Identical |
DIN EN 14604:2016-02 (Draft) | Identical |
NEN EN 14604 : 2005 C1 2008 | Identical |
I.S. EN 14604:2005 | Identical |
NF EN 14604 : 2005 | Identical |
EN 14604:2005/AC:2008 | Identical |
12/30260280 DC : 0 | BS 5839-6 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 6: CODE OF PRACTICE FOR THE DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE OF FIRE DETECTION AND FIRE ALARM SYSTEMS IN DOMESTIC PREMISES |
15/30253829 DC : 0 | BS 3632 - RESIDENTIAL PARK HOMES - SPECIFICATION |
BS 5839-6:2013 | Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of fire detection and fire alarm systems in domestic premises |
14/30277275 DC : 0 | BS 5446-3 - FIRE DETECTION AND FIRE ALARM DEVICES FOR DWELLINGS - PART 3: SPECIFICATION FOR FIRE AND CARBON MONOXIDE ALARM SYSTEMS FOR DEAF AND HARD OF HEARING PEOPLE |
09/30169955 DC : 0 | BS 8511 - CODE OF PRACTICE FOR THE INSTALLATION OF SOLID FUEL HEATING APPLIANCES ON BOATS |
BS 8511:2010 | Code of practice for the installation of solid fuel heating and cooking appliances in small craft |
BS 5446-3:2015 | Detection and alarm devices for dwellings Specification for fire alarm and carbon monoxide alarm systems for deaf and hard of hearing people |
93/68/EEC : 1993 AMD 2 1998 | COUNCIL DIRECTIVE 93/68/EEC OF 22.7.93 AMENDING DIRECTIVES 87/404/EEC, 88/378/EEC, 89/106/EEC, 89/336/EEC, 89/392/EEC, 89/686/EEC, 90/384/EEC, 90/385/EEC, 90/396/EEC, 91/263/EEC, 92/42/EEC AND 73/23/EEC |
IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV | Information technology equipment - Safety - Part 1: General requirements |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
EN 60065:2014/AC:2017-01 | AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS (IEC 60065:2014/COR2:2016) |
89/106/EEC : 1988 | COUNCIL DIRECTIVE OF 21 DECEMBER 1988 ON THE APPROXIMATION OF LAWS, REGULATIONS AND ADMINISTRATIVE PROVISIONS OF THE MEMBER STATES RELATING TO CONSTRUCTION PRODUCTS |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 60950-1:2006/A2:2013 | INFORMATION TECHNOLOGY EQUIPMENT - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60950-1:2005/A2:2013, MODIFIED) |
EN 61672-1:2013 | Electroacoustics - Sound level meters - Part 1: Specifications |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
EN 573-4:2004 | Aluminium and aluminium alloys - Chemical composition and form of wrought products - Part 4: Forms of products |
EN 54-3:2014 | Fire detection and fire alarm systems - Part 3: Fire alarm devices - Sounders |
ISO 9001:2015 | Quality management systems — Requirements |
IEC 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
EN 573-3:2013 | Aluminium and aluminium alloys - Chemical composition and form of wrought products - Part 3: Chemical composition and form of products |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.