BS EN 140100:2008
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Sectional specification. Fixed low power film resistors
Hardcopy , PDF
02-28-2015
English
04-30-2008
1 General
1.1 Scope
1.2 Information to be specified in the detail specification
2 Preferred characteristics, ratings and severities for
environmental and overload tests
2.1 Preferred characteristics
2.1.1 Style and dimensions
2.1.2 Preferred climatic categories
2.1.3 Temperature coefficients of resistance
2.1.4 Limits of change of resistance
2.2 Preferred values of ratings
2.2.1 Rated resistance
2.2.2 Tolerances on rated resistance
2.2.3 Rated dissipation (in the mounted state)
2.2.4 Limiting element voltage
2.2.5 Insulation resistance (insulated styles only)
2.2.6 Insulation voltage (insulated styles only)
2.2.7 Combinations of tolerance on rated resistance and
temperature coefficient
2.3 Preferred test severities
2.3.1 Damp heat, steady state
2.3.2 Vibration
2.3.3 Low air pressure
2.3.4 Rapid change of temperature
2.3.5 Solderability
2.3.6 Resistance to soldering heat
2.3.7 Overload
2.3.8 Single pulse high voltage overload
2.3.9 Periodic electric overload
2.3.10 Resistance to electrostatic discharge
2.3.11 Flammability
2.4 Preparation of specimen
2.4.1 Drying
2.4.2 Mounting of components on a test rack
2.4.3 Mounting of components on test boards
3 Quality assessment procedures
3.1 General
3.1.1 Structurally similar components
3.1.2 Formation of inspection lots
3.2 Qualification approval on the basis of the fixed
sample size procedure
3.3 Quality conformance inspection
3.4 Technology approval
3.5 Assessed process average procedures
3.6 Delayed delivery
Annex A (normative) - Fixed sample size Qualification
Approval and Quality Conformance Inspection
test schedule for fixed low power resistors
Annex B (informative) - Letter symbols and abbreviations
Bibliography
Describes the preferred values for characteristics and ratings and also the inspection requirements for fixed film resistors of assessed quality.
Committee |
W/-
|
DevelopmentNote |
Supersedes BS CECC 40100(1981) Supersedes 93/215591 DC. (05/2002) Supersedes 06/30155922 DC. (04/2008)
|
DocumentType |
Standard
|
Pages |
30
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
NEN EN 140100 : 2008 | Identical |
SN EN 140100 : 2008 | Identical |
NF EN 140100 : 2013 | Identical |
DIN EN 140100:2008-08 | Identical |
EN 140100:2008 | Identical |
I.S. EN 140100:2008 | Identical |
IEC 61193-2:2007 | Quality assessment systems - Part 2: Selection and use of sampling plans for inspection of electronic components and packages |
IEC 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
CECC 240001 : 1996 | FIXED LOW POWER FILM RESISTORS (LEADED/UNLEADED) |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IECQ 001002-3:2005 | IEC QUALITY ASSESSMENT SYSTEM FOR ELECTRONIC COMPONENTS (IECQ) - RULES OF PROCEDURE - PART 3: APPROVAL PROCEDURES |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
IEC 60068-2-13:1983 | Basic environmental testing procedures - Part 2-13: Tests - Test M: Low air pressure |
IEC 60286-2:2015 | Packaging of components for automatic handling - Part 2: Tape packaging of components with unidirectional leads on continuous tapes |
HD 349 : 200S1 | PREFERRED DIAMETERS OF WIRE TERMINATIONS OF CAPACITORS AND RESISTORS |
EN 61760-1:2006 | SURFACE MOUNTING TECHNOLOGY - PART 1: STANDARD METHOD FOR THE SPECIFICATION OF SURFACE MOUNTING COMPONENTS (SMDS) |
IEC 61760-1:2006 | Surface mounting technology - Part 1: Standard method for the specification of surface mounting components (SMDs) |
EN 60027-1:2006/A2:2007 | LETTER SYMBOLS TO BE USED IN ELECTRICAL TECHNOLOGY - PART 1: GENERAL |
EN 60286-2:2015 | Packaging of components for automatic handling - Part 2: Tape packaging of components with unidirectional leads on continuous tapes |
IEC 60027-1:1992 | Letters symbols to be used in electrical technology - Part 1: General |
EN 100014:1991 | Basic Specification: CECC assessed process average procedure (60% confidence limit) |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
IEC 60294:2012 | Measurement of the dimensions of a cylindrical component with axial terminations |
EN 61193-2 : 2007 | QUALITY ASSESSMENT SYSTEMS - PART 2: SELECTION AND USE OF SAMPLING PLANS FOR INSPECTION OF ELECTRONIC COMPONENTS AND PACKAGES |
EN 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 60115-1:2011/A11:2015 | FIXED RESISTORS FOR USE IN ELECTRONIC EQUIPMENT - PART 1: GENERIC SPECIFICATION |
IEC TR 60440:1973 | Method of measurement of non-linearity in resistors |
EN 61340-3-1:2007 | Electrostatics - Part 3-1: Methods for simulation of electrostatic effects - Human body model (HBM) electrostatic discharge test waveforms |
IEC 60062:2016 | Marking codes for resistors and capacitors |
EN 60062:2016/AC:2016-12 | MARKING CODES FOR RESISTORS AND CAPACITORS (IEC 60062:2016/COR1:2016) |
IEC 61340-3-1:2006 | Electrostatics - Part 3-1: Methods for simulation of electrostatic effects - Human body model (HBM) electrostatic discharge test waveforms |
IEC 60301:2012 | Preferred diameters of wire terminations of capacitors and resistors |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 60068-2-13:1999 | Environmental testing - Part 2: Tests - Test M: Low air pressure |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
IEC 60063:2015 | Preferred number series for resistors and capacitors |
EN 100014 : 1991 | BASIC SPECIFICATION: CECC ASSESSED PROCESS AVERAGE PROCEDURE (60% CONFIDENCE LIMIT) |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 60286-1:2017 | Packaging of components for automatic handling - Part 1: Tape packaging of components with axial leads on continuous tapes |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
EN 60695-11-5:2017 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
IEC 60695-11-5:2016 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
EN 60068-2-45:1992/A1:1993 | Environmental testing - Part 2: Tests - Test Xa and guidance: Immersion in cleaning solvents |
EN 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60115-1:2008 | Fixed resistors for use in electronic equipment - Part 1: Generic specification |
IEC 60195:2016 | Method of measurement of current noise generated in fixed resistors |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.