• There are no items in your cart

BS EN 13528-2:2002

Current

Current

The latest, up-to-date edition.

Ambient air quality. Diffusive samplers for the determination of concentrations of gases and vapours. Requirements and test methods Specific requirements and test methods

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

10-11-2002

US$242.23
Excluding Tax where applicable

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Requirements
   5.1 Desorption efficiency (for samplers involving solvent
        desorption)
   5.2 Desorption efficiency (for samplers involving thermal
        desorption)
   5.3 Effect of air velocity/sampler orientation
   5.4 Storage (indirect-reading samplers)
   5.5 Shelf life
   5.6 Sampler integrity
   5.7 Blank value
   5.8 Field tests
   5.9 Uncertainty
   5.10 Instructions for use
   5.11 Sample identification
 6 General test conditions
   6.1 Reagents
   6.2 Apparatus
   6.3 Independent method
   6.4 Generation of calibration gas mixture
       6.4.1 General
       6.4.2 Calibration gas mixture
   6.5 Test conditions
       6.5.1 General
       6.5.2 Laboratory tests under repeatability conditions
             involving standard atmospheres (7.3, 7.4, 7,7,
             7.8 and annex A)
       6.5.3 Laboratory tests under reproducibility
             conditions involving standard atmospheres (7.5)
       6.5.4 Laboratory tests not involving standard
             atmospheres (7.2, 7.6, 7.9)
       6.5.5 Field tests
7 Test methods
   7.1 General
   7.2 Desorption efficiency
        7.2.1 Spiking methods for samplers involving solvent
              desorption
        7.2.2 Spiking methods for samplers involving thermal
              desorption
        7.2.3 Phase equilibrium method (samplers involving
              solvent desorption)
   7.3 Bias due to the selection of non-ideal sorbent (for
        samplers relying on reversible sorption)
        7.3.1 Procedure
        7.3.2 Calculation
   7.4 Test on influence of air velocity and sampler
        orientation
   7.5 Effect of environmental parameters on sampler
        performance (uptake rate)
        7.5.1 Procedure
        7.5.2 Calculation
   7.6 Storage (for indirect-reading samplers)
        7.6.1 Procedure
        7.6.2 Calculation
   7.7 Shelf life
   7.8 Sampler leak test
   7.9 Determination of the blank value
   7.10 Field tests
8 Calculation of uncertainty
   8.1 General
   8.2 Desorption efficiency
   8.3 Uptake rate
   8.4 Storage
   8.5 Shelf life
   8.6 Sampler integrity
   8.7 Blank value
   8.8 Type B errors
   8.9 Combined uncertainty
   8.10 Field tests
9 Levels of evaluation
10 Test report
11 Marking
Annex A (normative) Determination of diffusive uptake
        rates (indirect-reading samplers)
Annex B (normative) Calculation of exposure concentration
Annex C (informative) Calculation of uncertainty components
Bibliography

Gives specific performance requirements and test methods under prescribed laboratory and field conditions for diffusive samplers used for the determination of the concentration of gases or vapours in ambient air. Applicable to all stages of the measuring procedure, including transportation and storage of the sample where appropriate.

Committee
EH/2/3
DevelopmentNote
Supersedes 99/562585 DC. (11/2002) Reviewed and confirmed by BSI, June 2007. (05/2007)
DocumentType
Standard
Pages
30
PublisherName
British Standards Institution
Status
Current

ISO 6144:2003 Gas analysis — Preparation of calibration gas mixtures — Static volumetric method
EN 838:2010 Workplace exposure - Procedures for measuring gases and vapours using diffusive samplers - Requirements and test methods
EN 482:2012+A1:2015 Workplace exposure - General requirements for the performance of procedures for the measurement of chemical agents
ISO 6143:2001 Gas analysis — Comparison methods for determining and checking the composition of calibration gas mixtures
ISO 6142:2001 Gas analysis Preparation of calibration gas mixtures Gravimetric method
ENV 13005 : DRAFT 1999 GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT
ISO 5725:1986 Precision of test methods Determination of repeatability and reproducibility for a standard test method by inter-laboratory tests
ISO 6141:2015 Gas analysis Contents of certificates for calibration gas mixtures
CR 14377:2002 Air quality - Approach to uncertainty estimation for ambient air reference measurement methods
ISO 3534-1:2006 Statistics — Vocabulary and symbols — Part 1: General statistical terms and terms used in probability

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.