BS EN 12442-3:2000
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Animal tissues and their derivatives utilized in the manufacture of medical devices Validation of the elimination and/or inactivation of viruses and transmissible agents
Hardcopy , PDF
02-29-2008
English
11-15-2000
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 Literature search
6 Elimination and/or inactivation study of viruses and
transmissible agents
7 Final report
8 Review of final report
9 Routing monitoring and control of critical process
parameters
Annex A (normative) Requirements related to literature search
Annex B (informative) Guidance on scaling down
Annex C (informative) Guidance on the elimination and/or
inactivation study for viruses and
transmissible agents ('agents')
Annex D (informative) Statistical evaluation of virus titres
and reduction factors and assessment of
their validity
Annex E (informative) Calculation of reduction factors
Annex F (informative) Probability of detection of agents at
low concentrations
Annex ZA (informative) Clauses of this standard addressing
Essential Requirements or other
provisions of EU Directives
Bibliography
Defines the validation of elimination and/or inactivation of viruses and/or transmissible agents during the manufacture of medical devices utilizing materials of animal origin (excluding in-vitro diagnostic medical devices). Not applicable to moulds, yeasts and bacteria.
Committee |
CH/194
|
DevelopmentNote |
Supersedes 96/564160 DC (03/2002)
|
DocumentType |
Standard
|
Pages |
30
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
SN EN 12442-3 : 2000 | Identical |
DIN EN 12442-3:1998-05 (Draft) | Identical |
UNE-EN 12442-3:2001 | Identical |
EN 12442-3 : 2000 | Identical |
UNI EN 12442-3 : 2002 | Identical |
NBN EN 12442-3 : 2000 | Identical |
NS EN 12442-3 : 1ED 2000 | Identical |
I.S. EN 12442-3:2000 | Identical |
NF EN 12442-3 : 2000 | Identical |
NEN EN 12442-3 : 2000 | Identical |
DIN EN 12442-3:2001-01 | Identical |
CSA Z17665-2 : 2009 : R2014 | STERILIZATION OF HEALTH CARE PRODUCTS - MOIST HEAT - PART 2: GUIDANCE ON THE APPLICATION OF ISO 17665-1 |
UNI CEN ISO/TS 17665-2 : 2009 | STERILIZATION OF HEALTH CARE PRODUCTS - MOIST HEAT - PART 2: GUIDANCE ON THE APPLICATION OF ISO 17665-1 |
AAMI ISO TIR 17665-2 : 2009 | STERILIZATION OF HEALTH CARE PRODUCTS - MOIST HEAT - PART 2: GUIDANCE ON THE APPLICATION OF ANSI/AAMI/ISO 17665-1 |
CSA Z17665-2:09 (R2019) | Sterilization of health care products — Moist heat — Part 2: Guidance on the application of ISO 17665-1 (ISO/TS 17665-2:2009, IDT) |
ASTM F 2150 : 2013 : REDLINE | Standard Guide for Characterization and Testing of Biomaterial Scaffolds Used in Tissue-Engineered Medical Products |
ASTM F 2027 : 2016 : REDLINE | Standard Guide for Characterization and Testing of Raw or Starting Materials for Tissue-Engineered Medical Products |
AAMI/ISO TIR17665-2:2009(R2016) | STERILIZATION OF HEALTH CARE PRODUCTS - MOIST HEAT - PART 2: GUIDANCE ON THE APPLICATION OF ANSI/AAMI/ISO 17665-1 |
DD CEN ISO/TS 17665-2:2009 | Sterilization of health care products. Moist heat Guidance on the application of ISO 17665-1 |
S.R. CEN ISO TS 17665-2:2009 | STERILIZATION OF HEALTH CARE PRODUCTS - MOIST HEAT - PART 2: GUIDANCE ON THE APPLICATION OF ISO 17665-1 |
ISO/TS 17665-2:2009 | Sterilization of health care products — Moist heat — Part 2: Guidance on the application of ISO 17665-1 |
CEN ISO/TS 17665-2:2009 | Sterilization of health care products - Moist heat - Part 2: Guidance on the application of ISO 17665-1 (ISO/TS 17665-2:2009) |
EN 550 : 1994 | STERILIZATION OF MEDICAL DEVICES - VALIDATION AND ROUTINE CONTROL OF ETHYLENE OXIDE STERILIZATION |
EN 1174-3 : 1996 | STERILIZATION OF MEDICAL DEVICES - ESTIMATION OF THE POPULATION OF MICRO-ORGANISMS ON PRODUCT - GUIDE TO THE METHODS FOR VALIDATION OF MICROBIOLOGICAL TECHNIQUES |
EN 46001 : 1996 | QUALITY SYSTEMS - MEDICAL DEVICES - PARTICULAR REQUIREMENTS FOR THE APPLICATION OF EN ISO 9001 |
EN 1174-1 : 1996 | STERILIZATION OF MEDICAL DEVICES - ESTIMATION OF THE POPULATION OF MICRO-ORGANISMS ON PRODUCT - REQUIREMENTS |
EN ISO 9002:1994/AC:1997 | QUALITY SYSTEMS - SPECIFICATION FOR PRODUCTION AND INSTALLATION |
EN 1174-2 : 1996 | STERILIZATION OF MEDICAL DEVICES - ESTIMATION OF THE POPULATION OF MICRO-ORGANISMS ON PRODUCT - GUIDANCE |
EN 552:1994/A2:2000 | STERILIZATION OF MEDICAL DEVICES - VALIDATION AND ROUTINE CONTROL OF STERILIZATION BY IRRADIATION |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
EN 46002 : 1996 | QUALITY SYSTEMS - MEDICAL DEVICES - PARTICULAR REQUIREMENTS FOR THE APPLICATION OF EN ISO 9002 |
EN 12442-1 : 2000 | ANIMAL TISSUES AND THEIR DERIVATIVES UTILIZED IN THE MANUFACTURE OF MEDICAL DEVICES - PART 1: ANALYSIS AND MANAGEMENT OF RISK |
EN ISO 14160:2011 | Sterilization of health care products - Liquid chemical sterilizing agents for single-use medical devices utilizing animal tissues and their derivatives - Requirements for characterization, development, validation and routine control of a sterilization process for medical devices (ISO 14160:2011) |
EN 12442-2 : 2000 | ANIMAL TISSUES AND THEIR DERIVATIVES UTILIZED IN THE MANUFACTURE OF MEDICAL DEVICES - PART 2: CONTROLS ON SOURCING, COLLECTION AND HANDLING |
EN 554 : 1994 | STERILIZATION OF MEDICAL DEVICES - VALIDATION AND ROUTINE CONTROL OF STERILIZATION BY MOIST HEAT |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.