BS EN 12405-3:2015
Current
The latest, up-to-date edition.
Gas meters. Conversion devices Flow computer
Hardcopy , PDF
English
12-31-2015
European foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and symbols
4 Principle of measurement
5 Rated operating conditions
6 Construction requirements
7 Installation requirements
8 Performance
9 Tests of conformity
10 Marking
11 Installation and operating instructions
Annex A (normative) - Type test
Annex B (normative) - Pressure transducers
Annex C (normative) - Temperature transducers
Annex D (normative) - Requirements and testing
of meter error correction
Annex E (informative) - Range of application of meter
error correction with functions: e(Q) or e (Re)
Bibliography
Defines the requirements and tests for the construction, performance, safety and conformity of flow computers (FCs) used to meet the metrological and technical requirements of a high accuracy volume conversion device.
Committee |
GSE/25
|
DevelopmentNote |
Supersedes 13/30289289 DC. (12/2015)
|
DocumentType |
Standard
|
Pages |
82
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
Part3 of this European Standard specifies the requirements and tests for the construction, performance, safety and conformity of flow computers (FCs) used to meet the metrological and technical requirements of a high accuracy volume conversion device. They are used to determine volume of fuel gases, including those of the first and second families according to EN437 . For the purpose of this European Standard, only flow computers that are intended to operate with ultrasonic meters according to ISO17089‑1 or gas turbine meters conforming to EN12261 are considered. For the purpose of this European Standard only classification classes E2 and M1 are considered for the flow computer calculator. FCs are equipped with external separate transducers for pressure and temperature which may be approved separately. The provisions concerning pressure and temperature transducers are given in AnnexB and C. Requirements and tests are given for energy calculator in EN12405‑2 .
Standards | Relationship |
EN 12405-3:2015 | Identical |
EN 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV | Information technology equipment - Safety - Part 1: General requirements |
EN 50160 : 2010 AMD 1 2015 | VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC ELECTRICITY NETWORKS |
EN 60068-3-1:2011 | Environmental testing - Part 3-1: Supporting documentation and guidance - Cold and dry heat tests |
EN 12405-1:2005+A2:2010 | Gas meters - Conversion devices - Part 1: Volume conversion |
EN ISO 13443:2005 | Natural gas - Standard reference conditions (ISO 13443:1996 including Corrigendum 1:1997) |
EN 61000-4-1:2007 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
ISO 6976:2016 | Natural gas — Calculation of calorific values, density, relative density and Wobbe indices from composition |
OIML D 11 : 2013 | GENERAL REQUIREMENTS FOR MEASURING INSTRUMENTS - ENVIRONMENTAL CONDITIONS |
IEC 61000-4-1:2006 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
ISO 5168:2005 | Measurement of fluid flow — Procedures for the evaluation of uncertainties |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60079-0:2012/A11:2013 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED) |
IEC 60068-3-1:2011 | Environmental testing - Part 3-1: Supporting documentation and guidance - Cold and dry heat tests |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC 62054-21:2004+AMD1:2017 CSV | Electricity metering (AC) - Tariff and load control - Part 21: Particular requirements for time switches |
EN 24006:1993 | Measurement of fluid flow in closed conduits - Vocabulary and symbols (ISO 4006:1991) |
EN 60950-1:2006/A2:2013 | INFORMATION TECHNOLOGY EQUIPMENT - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60950-1:2005/A2:2013, MODIFIED) |
EN 60068-2-64:2008 | ENVIRONMENTAL TESTING - PART 2-64: TESTS - TEST FH: VIBRATION, BROADBAND RANDOM AND GUIDANCE |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
ISO 12213-3:2006 | Natural gas Calculation of compression factor Part 3: Calculation using physical properties |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
ISO/IEC/IEEE 60559:2011 | Information technology — Microprocessor Systems — Floating-Point arithmetic |
IEC 60068-2-31:2008 | Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens |
IEC 60068-2-64:2008 | Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
IEC 61520:2000 | Metal thermowells for thermometer sensors - Functional dimensions |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
ISO/IEC Guide 99:2007 | International vocabulary of metrology Basic and general concepts and associated terms (VIM) |
EN 60079-11:2012 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
IEC 60079-11:2011 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
ISO 7498-2:1989 | Information processing systems Open Systems Interconnection Basic Reference Model Part 2: Security Architecture |
ISO 15970:2008 | Natural gas Measurement of properties Volumetric properties: density, pressure, temperature and compression factor |
EN 60947-5-6:2000 | Low-voltage switchgear and controlgear - Part 5-6: Control circuit devices and switching elements - DC interface for proximity sensors and switching amplifiers (NAMUR) |
EN 437:2003+A1:2009 | Test gases - Test pressures - Appliance categories |
EN 60751:2008 | INDUSTRIAL PLATINUM RESISTANCE THERMOMETERS AND PLATINUM TEMPERATURE SENSORS |
EN 60079-25:2010/AC:2013 | EXPLOSIVE ATMOSPHERES - PART 25: INTRINSICALLY SAFE ELECTRICAL SYSTEMS (IEC 60079-25:2010) |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 61000-4-8:2010 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
ISO 13443:1996 | Natural gas Standard reference conditions |
EN 22768-1:1993 | General tolerances - Part 1: Tolerances for linear and angular dimensions without individual tolerance indications (ISO 2768-1:1989) |
EN ISO 12213-3:2009 | Natural gas - Calculation of compression factor - Part 3: Calculation using physical properties (ISO 12213-3:2006) |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60079-25:2010 | Explosive atmospheres - Part 25: Intrinsically safe electrical systems |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
IEC 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
IEC 60751:2008 | Industrial platinum resistance thermometers and platinum temperature sensors |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
ISO 17089-1:2010 | Measurement of fluid flow in closed conduits - Ultrasonic meters for gas Part 1: Meters for custody transfer and allocation measurement |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
EN ISO 6976:2016 | Natural gas - Calculation of calorific values, density, relative density and Wobbe indices from composition (ISO 6976:2016) |
EN ISO 12213-2:2009 | Natural gas - Calculation of compression factor - Part 2: Calculation using molar-composition analysis (ISO 12213-2:2006) |
ISO 12213-2:2006 | Natural gas Calculation of compression factor Part 2: Calculation using molar-composition analysis |
IEC 61000-4-29:2000 | Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests |
EN 12405-2:2012 | Gas meters - Conversion devices - Part 2: Energy conversion |
ISO 4006:1991 | Measurement of fluid flow in closed conduits — Vocabulary and symbols |
EN 61000-4-29:2000 | Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests |
IEC 60947-5-6:1999 | Low-voltage switchgear and controlgear - Part 5-6: Control circuit devices and switching elements - DC interface for proximity sensors and switching amplifiers (NAMUR) |
EN ISO 15970:2014 | Natural gas - Measurement of properties - Volumetric properties: density, pressure, temperature and compression factor (ISO 15970:2008) |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
EN 1776:2015 | Gas infrastructure - Gas measuring systems - Functional requirements |
EN 60068-2-31:2008 | ENVIRONMENTAL TESTING - PART 2-31: TESTS - TEST EC: ROUGH HANDLING SHOCKS, PRIMARILY FOR EQUIPMENT-TYPE SPECIMENS |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.