BS EN 12150-2:2004
Current
The latest, up-to-date edition.
Glass in building. Thermally toughened soda lime silicate safety glass Evaluation of conformity/Product standard
Hardcopy , PDF
English
10-18-2004
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
4.1 Product description
4.2 Conformity with the definition of thermally strengthened
soda lime silicate safety glass
4.3 Determination of the characteristic's performances
4.3.1 Characteristics of thermally strengthened soda
lime silicate safety glass
4.3.2 Determination of characteristics of thermally
strengthened soda lime silicate safety glass products
4.4 Durability
4.5 Dangerous substances
5 Evaluation of conformity
5.1 General
5.2 Initial type testing of the product
5.2.1 General
5.2.2 Initial type testing of thermally strengthened
soda lime silicate safety glass
5.2.3 Initial type testing of characteristic's performances
5.3 Factory production control and inspection of samples in
accordance with a prescribed test plan
5.4 Initial inspection of factory and of factory production
control
5.5 Continuous surveillance and assessment of the factory
production control
6 Marking and/or labelling
6.1 General
6.2 Product marking
6.3 Product characteristics
6.4 'Characteristics/performance identification paper'
Annex A (normative) Factory production control
A.1 Factory Production Control Requirements
A.1.1 General
A.1.2 Organisation
A.1.3 Control system
A.2 Marking
A.3 Inspection and testing tables of chemically strengthened
soda lime silicate safety glass production
A.3.1 Information on Table A.1
A.3.2 Use of proxy testing
Annex B (informative) Test for factory production control
B.1 Strength Measurement
B.1.1 Four point bending strength test
B.1.2 Optical surface pre-stress measurement
B.2 Fragmentation test
B.2.1 Requirements
B.2.2 Test method
Annex C (informative) Provisions for voluntary involvement of
third party(ies)
C.1 General
C.2 Voluntary tasks for third parties
C.3 Marking and labelling
Annex ZA (informative) Clauses of this European Standard addressing
the provisions of EU Construction Products
Directive
ZA.1 Scope and relevant characteristics
ZA.2 Procedure(s) for the attestation of conformity of
thermally toughened soda lime silicate safety glass
products
ZA.2.1 System(s) of attestation of conformity
ZA.2.2 EC Certificate and Declaration of conformity
ZA.3 CE marking and labelling
Bibliography
Describes the evaluation of conformity and the factory production control of flat thermally toughened soda lime silicate safety glass for use in buildings.
Committee |
B/520
|
DevelopmentNote |
Supersedes 01/105365 DC (11/2004)
|
DocumentType |
Standard
|
Pages |
42
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This document covers the evaluation of conformity and the factory production control of flat thermally toughened soda lime silicate safety glass for use in buildings. Note: For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.
Standards | Relationship |
UNE-EN 12150-2:2005 | Identical |
EN 12150-2:2004 | Identical |
NF EN 12150-2 : 2005 | Identical |
UNI EN 12150-2 : 2005 | Identical |
NEN EN 12150-2 : 2004 | Identical |
DIN EN 12150-2:2005-01 | Identical |
SN EN 12150-2 : 2004 | Identical |
I.S. EN 12150-2:2004 | Identical |
NBN EN 12150-2 : 2005 | Identical |
NS EN 12150-2 : 1ED 2005 | Identical |
08/30143158 DC : DRAFT AUG 2008 | BS 644 - TIMBER WINDOWS - FULLY FINISHED FACTORY ASSEMBLED WINDOWS OF VARIOUS TYPES - SPECIFICATION |
BS 6262-7:2017 | Glazing for buildings Code of practice for the provision of information |
BS 6262-1:2017 | Glazing for buildings General methodology for the selection of glazing |
BS 7412:2007 | Specification for windows and doorsets made from unplasticized polyvinyl chloride (PVC-U) extruded hollow profiles |
06/30143171 DC : DRAFT SEP 2006 | BS 7412 - PLASTICS WINDOWS AND DOORSETS MADE FROM UNPLASTICIZED POLYVINYL CHLORIDE (PVC-U) EXTRUDED HOLLOW PROFILES |
PREN 13501-5 : DRAFT 2015 | FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 5: CLASSIFICATION USING DATA FROM EXTERNAL FIRE EXPOSURE TO ROOFS TESTS |
EN 673:2011 | Glass in building - Determination of thermal transmittance (U value) - Calculation method |
EN 12758:2011 | Glass in building - Glazing and airborne sound insulation - Product descriptions and determination of properties |
EN 410:2011 | Glass in building - Determination of luminous and solar characteristics of glazing |
EN 1096-1:2012 | Glass in building - Coated glass - Part 1: Definitions and classification |
EN 12898:2001 | Glass in building - Determination of the emissivity |
EN 13541:2012 | Glass in building - Security glazing - Testing and classification of resistance against explosion pressure |
EN 13501-2:2016 | Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services |
EN 1288-3:2000 | Glass in building - Determination of the bending strength of glass - Part 3: Test with specimen supported at two points (four point bending) |
EN 572-2:2012 | Glass in building - Basic soda lime silicate glass products - Part 2: Float glass |
EN 12150-1:2015 | Glass in building - Thermally toughened soda lime silicate safety glass - Part 1: Definition and description |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
EN 1063:1999 | Glass in building - Security glazing - Testing and classification of resistance against bullet attack |
EN 572-4:2012 | Glass in building - Basic soda lime silicate glass products - Part 4: Drawn sheet glass |
EN 357:2004 | Glass in building - Fire resistant glazed elements with transparent or translucent glass products - Classification of fire resistance |
ISO 9001:2015 | Quality management systems — Requirements |
EN 572-1:2012+A1:2016 | Glass in building - Basic soda-lime silicate glass products - Part 1: Definitions and general physical and mechanical properties |
EN 356:1999 | Glass in building - Security glazing - Testing and classification of resistance against manual attack |
EN 572-5:2012 | Glass in building - Basic soda lime silicate glass products - Part 5: Patterned glass |
EN 1096-3:2012 | Glass in building - Coated glass - Part 3: Requirements and test methods for class C and D coatings |
EN 12600:2002 | Glass in building - Pendulum test - Impact test method and classification for flat glass |
EN 1096-2:2012 | Glass in building - Coated glass - Part 2: Requirements and test methods for class A, B and S coatings |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.