BS EN 12050-1:2015
Current
The latest, up-to-date edition.
Wastewater lifting plants for buildings and sites Lifting plants for wastewater containing faecal matter
Hardcopy , PDF
English
03-31-2015
Foreword
1 Scope
2 Normative references
3 Terms, definitions, symbols and abbreviations
4 Materials and product characteristics
5 Testing
6 Assessment and verification of constancy of performance - AVCP
7 Marking, labelling and packaging
8 Manufacturer's instructions for installation, operation and maintenance
Annex A (informative) - Recommended materials
Annex ZA (informative) - Clauses of this European Standard addressing
the provisions of the EU Construction Products Regulation
Bibliography
Pertains to lifting plants for wastewater containing faecal matter (referred to as 'faecal lifting plants' in this standard) for drainage of locations below flood level in buildings and sites to prevent any backflow of wastewater into the building.
Committee |
B/505
|
DevelopmentNote |
Supersedes 95/106296 DC. (08/2004) Supersedes 12/30265289 DC. (03/2015)
|
DocumentType |
Standard
|
Pages |
44
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard applies to lifting plants for wastewater containing faecal matter (referred to as “faecal lifting plants” in this standard) for drainage of locations below flood level in buildings and sites to prevent any backflow of wastewater into the building. These lifting plants may be prefabricated or delivered as prefabricated kits and assembled on site. This standard specifies general requirements, basic construction and testing principles, together with information on materials and assessment and verification of constancy of performance. Construction and testing requirements for non-return valves used in wastewater lifting plants are given in EN12050‑4 . This European Standard does not apply for pumping installations for drain and sewer systems outside buildings for pumping of municipal wastewater according to EN752:2008, AnnexF. NOTE Lifting plants for wastewater containing faecal matter can also be used for wastewater that does not contain faecal matter and for surface water. This European Standard applies also to lifting plants for wastewater containing faecal matter which are not prefabricated but composed of individual components purchased from different suppliers and put together on site.
Standards | Relationship |
NS EN 12050-1 : 2015 | Identical |
NBN EN 12050-1 : 2015 | Identical |
NF EN 12050-1 : 2015 | Identical |
UNE-EN 12050-1:2015 | Identical |
SN EN 12050-1 : 2015 | Identical |
DIN EN 12050-1:2015-05 | Identical |
I.S. EN 12050-1:2015 | Identical |
NEN EN 12050-1 : 2015 | Identical |
EN 12050-1:2015 | Identical |
UNI EN 12050-1 : 2003 | Identical |
ISO 9906:2012 | Rotodynamic pumps — Hydraulic performance acceptance tests — Grades 1, 2 and 3 |
EN 12566-1:2016 | Small wastewater treatment systems for up to 50 PT - Part 1: Prefabricated septic tanks |
EN 13598-1:2010 | Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 1: Specifications for ancillary fittings including shallow inspection chambers |
EN 60079-0:2012/A11:2013 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED) |
EN 12050-4:2015 | Wastewater lifting plants for buildings and sites - Part 4: Non-return valves for faecal-free wastewater and wastewater containing faecal matter |
EN 12056-4:2000 | Gravity drainage systems inside buildings - Part 4: Wastewater lifting plants - Layout and calculation |
EN 13463-1:2009 | Non-electrical equipment for use in potentially explosive atmospheres - Part 1: Basic method and requirements |
EN 13598-2:2016 | Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 2: Specifications for manholes and inspection chambers |
EN 12566-4:2016 | Small wastewater treatment systems for up to 50 PT - Part 4: Septic tanks assembled in situ from prefabricated kits |
EN 12056-1:2000 | Gravity drainage systems inside buildings - Part 1: General and performance requirements |
EN 10025-1:2004 | Hot rolled products of structural steels - Part 1: General technical delivery conditions |
EN 13823:2010+A1:2014 | Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 752:2017 | Drain and sewer systems outside buildings - Sewer system management |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
EN 124:1994 | Gully tops and manhole tops for vehicular and pedestrian areas - Design requirements, type testing, marking, quality control |
ISO 9001:2015 | Quality management systems — Requirements |
EN 1563:2011 | Founding - Spheroidal graphite cast irons |
EN 10130:2006 | Cold rolled low carbon steel flat products for cold forming - Technical delivery conditions |
EN ISO 9906:2012 | Rotodynamic pumps - Hydraulic performance acceptance tests - Grades 1, 2 and 3 (ISO 9906:2012) |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
ISO 20361:2015 | Liquid pumps and pump units Noise test code Grades 2 and 3 of accuracy |
EN 206:2013+A1:2016 | Concrete - Specification, performance, production and conformity |
EN 1561:2011 | Founding - Grey cast irons |
EN 10088-1:2014 | Stainless steels - Part 1: List of stainless steels |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.