BS 9250:2007
Current
The latest, up-to-date edition.
Code of practice for design of the airtightness of ceilings in pitched roofs
Hardcopy , PDF
English
05-31-2007
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Design criteria
5 Materials, fittings and accessories
6 Design details and installation
Annex A (informative) Requirements for airtightness
and control of condensation in the Building
Regulations
Bibliography
List of figures
List of tables
Gives guidance on methods that can be used to meet the "well sealed ceiling" requirements defined in BS 5250 for cold and warm pitched roofs.
Committee |
B/542/1
|
DevelopmentNote |
Supersedes 06/30137888 DC. (06/2007) Reviewed and confirmed by BSI, January 2013. (12/2012)
|
DocumentType |
Standard
|
Pages |
48
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This standard provides guidance on methods that can be used to meet the “well sealed ceiling” requirements defined in BS5250 for cold and warm pitched roofs.
This standard provides architects, house builders, and building control officers with robust design details for the construction of more airtight ceilings and for the control of air movement into pitched roofs.
It provides guidance for dwellings and buildings of domestic type construction on the selection of materials, design principles, construction methods and design details covering: the junction of walls and ceilings; junctions of ceiling materials; penetration through ceilings (e.g. pipes, outlets, cables, light fittings, loft hatches, tubular rooflights and roof windows).
It includes cold and warm roof applications and will apply to new, and the refurbishment of existing, buildings.
BS 5534(2014) : 2014 | SLATING AND TILING FOR PITCHED ROOFS AND VERTICAL CLADDING - CODE OF PRACTICE |
BS 5918:2015 | Solar heating systems for domestic hot water. Code of practice for design and installation |
13/30274184 DC : 0 | BS 5918 - SOLAR HEATING SYSTEMS FOR DOMESTIC HOT WATER - CODE OF PRACTICE |
11/30171810 DC : DRAFT APR 2011 | BS 5250 - CODE OF PRACTICE FOR CONTROL OF CONDENSATION IN BUILDINGS |
13/30271503 DC : 0 | BS 5534 - SLATING AND TILING FOR PITCHED ROOFS AND VERTICAL CLADDING - CODE OF PRACTICE |
BS 5250(2011) : 2011 | CODE OF PRACTICE FOR CONTROL OF CONDENSATION IN BUILDINGS |
BS 7116:1990 | Specification for double sided pressure sensitive adhesive tapes |
BS EN 13141-1:2004 | Ventilation for buildings. Performance testing of components/products for residential ventilation Externally and internally mounted air transfer devices |
EN 60598-2-1:1989 | Luminaires - Part 2: Particular requirements - Section 1: Fixed general purpose luminaires |
BS EN 13963:2014 | Jointing materials for gypsum boards. Definitions, requirements and test methods |
BS EN 60598-2-2:2012 | Luminaires Particular requirements. Recessed luminaires |
BS 6093(2006) : 2006 | DESIGN OF JOINTS AND JOINTING IN BUILDING CONSTRUCTION - GUIDE |
BS 8000-16(1997) : 1997 | WORKMANSHIP ON BUILDING SITES - PART 16: CODE OF PRACTICE FOR SEALING JOINTS IN BUILDINGS USING SEALANTS |
BS 4533-102.1:1990 | Luminaires. Particular requirements Specification for fixed general purpose luminaires |
IEC 60598-2-2:2011 | Luminaires - Part 2-2: Particular requirements - Recessed luminaires |
BS 6213(2000) : 2000 | SELECTION OF CONSTRUCTION SEALANTS - GUIDE |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-