BS 88-2:2007
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Low-voltage fuses Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application). Examples of standardized systems of fuses A to I
Hardcopy , PDF
11-30-2010
English
06-29-2007
Fuse system E - Fuses with fuse-links for bolted connections
(BS bolted fuse system)
1 General
1.1 Scope
2 Terms and definitions
3 Conditions for operation in service
4 Classification
5 Characteristics of fuses
5.5 Rated power dissipation of a fuse-link and rated
acceptable power dissipation of a fuse-holder
5.6 Limits of time-current characteristics
6 Markings
6.1 Markings of fuse-holders
6.2 Markings of fuse-links
7 Standard conditions for construction
7.1 Mechanical design
7.9 Protection against electric shock
8 Tests
8.3 Verification of temperature rise and power dissipation
8.4 Verification of operation
8.5 Verification of breaking capacity
8.9 Verification of resistance to heat
8.10 Verification of non-deterioration of contacts
8.11 Mechanical and miscellaneous tests
Fuse system G - Fuses with fuse-links with offset blade
contacts (BS clip-in fuse system)
1 General
1.1 Scope
2 Terms and definitions
3 Conditions for operation in service
4 Classification
5 Characteristics of fuses
5.2 Rated voltage
5.5 Rated power dissipation of a fuse-link and rated
acceptable power dissipation of a fuse-holder
6 Markings
6.1 Markings of fuse-holders
6.2 Markings of fuse-links
7 Standard conditions for construction
7.1 Mechanical design
7.7 I[2]t characteristics
7.9 Protection against electric shock
8 Tests
8.9 Verification of resistance to heat
8.10 Verification of non-deterioration of contacts
8.11 Mechanical and miscellaneous tests
Fuse system I - gU fuse-links with wedge tightening contacts
1 General
1.1 Scope
2 Terms and definitions
3 Conditions for operation in service
3.9 Discrimination of fuse-links
4 Classification
5 Characteristics of fuses
5.2 Rated voltage
5.5 Rated power dissipation of a fuse-link
5.8 Cut-off current and I[2]t characteristics
6 Markings
6.1 Markings of fuse-holders
6.2 Markings of fuse-links
7 Standard conditions for construction
7.1 Mechanical design
7.5 Breaking capacity
7.7 I[2]t characteristics
7.8 Overcurrent discrimination of the fuse-links
8 Tests
8.9 Verification of resistance to heat
8.11 Mechanical and miscellaneous tests
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Bibliography
Applies to fuses with fuse-links having bolted connections. Such fuses have rated currents up to and including 1250 A and rated voltages up to and including 690 V a.c. and up to and including 500 V d.c.
Committee |
PEL/32
|
DevelopmentNote |
Supersedes BS 88-2.2(1988). Supersedes BS 88-5(1988). Supersedes BS 88-6(1988). Together with BS EN 60269-1 & BS 88-1(2007) supersedes BS EN 60269-2.(06/2007) To be read in conjunction with BS EN 60269-1. Supersedes 05/30135642 DC. (07/2007)
|
DocumentType |
Standard
|
Pages |
52
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 60060-2:2010 | High-voltage test techniques - Part 2: Measuring systems |
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV | Low-voltage fuses - Part 1: General requirements |
HD 588.1 : S1 AMD 1 | HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS |
EN 60112 : 2003 AMD 1 2009 | METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS |
EN ISO 6988:1994 | Metallic and other non-organic coatings - Sulfur dioxide test with general condensation of moisture (ISO 6988:1985) |
ISO 1207:2011 | Slotted cheese head screws Product grade A |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60060-3:1976 | High-voltage test techniques - Part 3: Measuring devices |
IEC 60060-4:1977 | High-voltage test techniques - Part 4: Application guide for measuring devices |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
ISO 6988:1985 | Metallic and other non organic coatings Sulfur dioxide test with general condensation of moisture |
EN 60269-1:2007/A2:2014 | LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS (IEC 60269-1:2006/A2:2014) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.