Methods
1 General
1.1 Scope
1.2 Definitions
2 General principles of measurement
2.1 Thermal conductivity, conductance and transmittance
2.2 Emissivity
2.3 Heat capacity per unit mass
3 Testing conditions and test reports
3.1 Temperatures of test
3.2 Conditioning of materials
3.3 Moisture content
3.4 Test reports
4 Methods for determining thermal properties
4.1 General
4.2 Thermal conductivity
4.3 Thermal transmittance and thermal conductance
(above approximately 0.7 W/(m2K))
4.4 Emissivity
4.5 Heat capacity per unit mass (temperatures up to
approximately 1000 deg C)
5 References
Appendices
A Additional methods of measuring thermal
conductivity
B Heat flow meter method of measuring thermal
conductivity with two test specimens
C Heat flow meter method of measuring thermal
conductivity with a single test specimen
D Transient state method of thermal conductivity
measurement
E Determination of thermal conductivity by the use of
a thermal probe
F Units and conversion factors
Tables
1 Summary of symbols and dimensions of quantities
2 Common shape factors
3 Methods for determining thermal properties
4 Quantity of heat (conversion factors)
5 Thermal transmission (conversion factors)
6 Thermal conductivity (conversion factors)
7 Thermal conductance, thermal transmittance, surface
coefficient, convection coefficient and radiation
coefficient (conversion factors)
8 Heat capacity per unit volume (conversion factors)
9 Thermal diffusivity (conversion factors)
Figures
1 Diagram illustrating definition 2
2 Spherical vessel for low temperature conductivity
tests
3 Heat flow meter apparatus
4 Heat flow meter with single specimen
5 Typical two specimen arrangement for transient
flow measurement of thermal properties
6 Differential thermocouples for measurement of
average temperature differences
7 Diagram of probe with thermocouple reference
junction
Meanings of relevant symbols with SI units. Dimensions, determination of thermal properties over various temperature ranges. Measurement of thermal conductivity, conversion tables for common units appended.
Committee |
B/540
|
DevelopmentNote |
Supersedes 71/34796 DC. (06/2004)
|
DocumentType |
Standard
|
Pages |
38
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
UNE-EN 150004:1991 | Identical |
ISO/TR 9165:1988 | Similar to |
BS 4508-4:1977 | Thermally insulated underground pipelines Specific testing and inspection requirements for cased systems without air gap |
BS 3533:1981 | Glossary of thermal insulation terms |
ISO 8990:1994 | Thermal insulation — Determination of steady-state thermal transmission properties — Calibrated and guarded hot box |
BS 3958-4:1982 | Thermal insulating materials Bonded preformed man-made mineral fibre pipe sections |
BS 3958-1:1982 | Thermal insulating materials Magnesia preformed insulation |
BS 3958-6:1972 | Thermal insulating materials Finishing materials; hard setting composition, self-setting cement and gypsum plaster |
BS 4370-2:1993 | Methods of test for rigid cellular materials Methods 7 to 9 |
BS 3958-2:1982 | Thermal insulating materials Calcium silicate preformed insulation |
EEMUA 147 : 2016 | RECOMMENDATIONS FOR REFRIGERATED LIQUEFIED GAS STORAGE TANKS |
BS 4618-3.3:1973 | Recommendations for the presentation of plastics design data. Thermal properties Thermal conductivity |
BS EN ISO 8990:1996 | Thermal insulation. Determination of steady-state thermal transmission properties. Calibrated and guarded hot box |
EN ISO 8990:1996 | Thermal insulation - Determination of steady-state thermal transmission properties - Calibrated and guarded hot box (ISO 8990:1994) |
BS 3708(1969) : LATEST | THE USE OF THERMAL INSULATING MATERIALS BETWEEN 230 DEGREES CENTIGRADE AND 650 DEGREES CENTIGRADE |
BS 1902-1A:1966 | Methods of testing refractory materials Sampling and physical tests |
BS 2972:1989 | Methods of test for inorganic thermal insulating materials |
BS 874-2.1:1986 | Methods for determining thermal insulating properties. Tests for thermal conductivity and related properties Guarded hot-plate method |
BS 1334(1969) : LATEST | THE USE OF THERMAL INSULATING MATERIALS FOR CENTRAL HEATING AND HOT AND COLD WATER SUPPLY INSTALLATIONS |
BS 874-1:1986 | Methods for determining thermal insulating properties Introduction, definitions and principles of measurement |
BS 3533:1981 | Glossary of thermal insulation terms |
BS 874-3.1:1987 | Methods for determining thermal insulating properties. Tests for thermal transmittance and conductance Guarded hot-box method |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.