BS 8660-1:2011
Current
The latest, up-to-date edition.
Gas-fired micro-cogeneration appliances of rated thermal input not exceeding 70 kW net Specification for selection, installation, inspection, commissioning, servicing and maintenance of Stirling engine micro-cogeneration appliances
Hardcopy , PDF
English
11-30-2011
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Competence
5 Environmental considerations
6 Selection of equipment and pre-installation
7 Installation
8 Post-installation
Annexes
Annex A (informative) - How a typical Stirling
engine micro-cogeneration appliance works
Annex B (informative) - Matching the heat output
of the micro-cogeneration appliance to the
heat load of the property
Bibliography
Describes requirements for the selection, installation, inspection, commissioning, servicing and maintenance of room-sealed gas-fired Stirling engine micro-cogeneration appliances and their protection devices designed to operate in parallel with public low-voltage distribution networks.
Committee |
GSE/30
|
DevelopmentNote |
Supersedes 10/30213917 DC. (11/2011)
|
DocumentType |
Standard
|
Pages |
66
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of BS 8660 specifies requirements for the selection, installation, inspection, commissioning, servicing and maintenance of room-sealed gas-fired Stirling engine micro-cogeneration appliances and their protection devices designed to operate in parallel with public low-voltage distribution networks.
NOTE 1 Sometimes micro-cogeneration appliances are referred to as small-scale embedded generators (SSEG), e.g. in Engineering Recommendation G83/1/1.
NOTE 2 A room-sealed appliance is designated as Type C in PD CEN/TR 1749.
The term “micro-cogeneration appliance” refers to equipment that:
is rated up to and including 16 A per phase, single or multiphase 230/400 V a.c.;
has a total rated heat input not exceeding 70 kW, based on net calorific value;
utilizes 1st, 2nd or 3rd family gases and is designed to operate in the condensing mode for the heating of domestic dwellings, including domestic dwellings in commercial premises, by the circulation of heated water in open or closed systems;
has been shown to meet the type verification tests in the appropriate annex of Engineering Recommendation G83/1/1;
carries a CE mark (see 6.2.1).
This standard does not apply to:
micro-cogeneration appliances with a rated input of over 70 kW;
groups of micro-cogeneration appliances with individual ratings of less than 70 kW with an aggregate input of greater than 70 kW.
NOTE 3 Groups of micro-cogeneration appliances with individual ratings of less than 70 kW, but with a maximum aggregate input of ≤70 kW, may be installed to this standard but specialist advice on the system design, installation and control needs to be sought from the appliance manufacturer.
It is not applicable to the detailed design and installation of the whole heating system, which is specified in BS EN 12828:2003 (incorporating corrigendum January 2009), BS EN 12831:2003 (incorporating corrigendum January 2009) and BS EN 14336:2004 (incorporating corrigendum January 2009).
NOTE 4 With the publication of BS EN 12828, BS EN 12831 and BS EN 14336, BS 5449 has been withdrawn. These standards are not aligned to UK design and installation practices; they cover commercial as well as domestic heating systems and exclude hot water. Consequently, these standards include national annexes covering all the relevant material from BS 5449.
NOTE 5 In this standard, heat input is expressed in terms of net calorific values (CV), unless stated otherwise. The ratio of gross to net heat input is approximately 1.11:1 for natural gas, 1.09:1 for propane, and 1.08:1 for butane.
NOTE 6 It is essential that persons carrying out the installation of any micro-cogeneration appliances are competent to do so. Clause 4 gives information on competence.
BS PAS 2030(2012) : 2012 | IMPROVING THE ENERGY EFFICIENCY OF EXISTING BUILDINGS - SPECIFICATION FOR INSTALLATION PROCESS, PROCESS MANAGEMENT AND SERVICE PROVISION |
BS 1179-6:1980 | Glossary of terms used in the gas industry Combustion and utilization including installation at consumers\' premises |
BS 5258-8:1980 | Safety of domestic gas appliances Combined appliances: gas fire/back boiler |
BS 7927:1998 | Heating appliances for domestic applications. Portable apparatus designed to detect and measure specific combustion flue gas products. Requirements |
BS EN 1491:2000 | Building valves. Expansion valves. Tests and requirements |
BS 6700(2006) : 2006 | DESIGN, INSTALLATION, TESTING AND MAINTENANCE OF SERVICES SUPPLYING WATER FOR DOMESTIC USE WITHIN BUILDINGS AND THEIR CURTILAGES - SPECIFICATION |
BS EN 14336:2004 | Heating systems in buildings. Installation and commissioning of water based heating systems |
BS 7967-2:2005 | Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for using electronic portable combustion gas analysers in the measurement of carbon monoxide and the determination of combustion performance |
BS 6400-2:2006 | Specification for installation, exchange, relocation and removal of gas meters with a maximum capacity not exceeding 6 m<sup>3</sup>/h Medium pressure (2nd family gases) |
PD 5482-3:2005 | Code of practice for domestic butane and propane gas-burning installations Installations in boats, yachts and other vessels |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 6400-3:2007 | Specification for installation, exchange, relocation and removal of gas meters with a maximum capacity not exceeding 6 m<sup>3</sup>/h Low and medium pressure (3rd family gases) |
BS 5482-2:1977 | Domestic butane- and propane-gas-burning installations Installations in caravans and non-permanent dwellings |
BS 3198:1981 | Specification for copper hot water storage combination units for domestic purposes |
BS 6400-1:2002 | Specification for installation of domestic-sized gas meters maximum rated capacity not exceeding 6 m<sup>3</sup>/h (2nd and 3rd family gases) Low pressure (2nd family gases) |
BS 7860:1996 | Specification for carbon monoxide detectors (electrical) for domestic use |
BS EN 13831:2007 | Closed expansion vessels with built-in diaphragm for installation in water |
BS 3632:2005 | Residential park homes. Specification |
BS EN 50379-3:2012 | Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances Performance requirements for apparatus used in non-statutory servicing of gas fired heating appliances |
BS 5449:1990 | Specification for forced circulation hot water central heating systems for domestic premises |
BS EN 1443:2003 | Chimneys. General requirements |
CR 1472:1997 | General guidance for the marking of gas appliances |
BS EN 50438:2013 | Requirements for micro-generating plants to be connected in parallel with public low-voltage distribution networks |
BS 7967-3:2005 | Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for responding to measurements obtained from electronic portable combustion gas analysers |
BS EN 50291:2001 | Electrical apparatus for the detection of carbon monoxide in domestic premises. Test methods and performance requirements |
BS EN 1856-1:2009 | Chimneys. Requirements for metal chimneys System chimney products |
BS 5546:2010 | Specification for installation and maintenance of gas-fired water-heating appliances of rated input not exceeding 70 kW net |
BS EN 12828 : 2012 | HEATING SYSTEMS IN BUILDINGS - DESIGN FOR WATER-BASED HEATING SYSTEMS |
BS 1179:1967 | Glossary of terms used in the gas industry |
BS 7967-1:2005 | Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for identifying and managing sources of fumes, smells, spillage/leakage of combustion products and carbon monoxide detector activation |
BS EN 12831:2003 | Heating systems in buildings. Method for calculation of the design heat load |
BS 5422:2009 | Method for specifying thermal insulating materials for pipes, tanks, vessels, ductwork and equipment operating within the temperature range -40°C to +700°C |
PD CEN/TR 1749:2014 | European scheme for the classification of gas appliances according to the method of evacuation of the combustion products (types) |
BS EN ISO 4126-1 : 2013 | SAFETY DEVICES FOR PROTECTION AGAINST EXCESSIVE PRESSURE - PART 1: SAFETY VALVES (ISO 4126-1:2013) |
BS 5871-2:2005 | Specification for the installation and maintenance of gas fires, convector heaters, fire/back boilers and decorative fuel effect gas appliances Inset live fuel effect gas fires of heat input not exceeding 15 kW, and fire/back boilers (2nd and 3rd family gases) |
BS 476-22:1987 | Fire tests on building materials and structures Method for determination of the fire resistance of non-loadbearing elements of construction |
BS 7967-4:2007 | Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for using electronic portable combustion gas analysers as part of the process of servicing and maintenance of gas-fired appliances |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.