BS 8592:2016
Current
The latest, up-to-date edition.
Electric cables. Thermosetting insulated, non-armoured, fire-resistant, single core non-sheathed cables of rated voltage 450/750 V, having low emission of smoke and corrosive gases when affected by fire. Specification
Hardcopy , PDF
English
03-31-2016
Foreword
0 Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Rated voltage
5 Conductors
6 Insulation
7 Identification of cable
8 Cable marking and additional information
9 Schedule of tests
10 Test conditions
11 Routine tests
12 Sample tests
13 Type tests
Annexes
Annex A (informative) - Guide to use and installation
of cables
Annex B (informative) - Notes on type tests
Bibliography
Gives requirements and test methods for the construction and performance of non-armoured, single core non-sheathed cables which: a) have a thermosetting insulation of rated voltage 450/750 V; b) provide resistance to fire (circuit integrity), including mechanical shock, as measured by performance in a standard test; c) emit limited amounts of smoke and corrosive gases when burned as measured by a standard test; d) are flame retardant; and e) are primarily, but not exclusively, intended for use inside metal enclosures such as steel conduit. inside metal enclosures such as steel conduit.
Committee |
GEL/20/17
|
DevelopmentNote |
Supersedes 15/30325295 DC. (04/2016)
|
DocumentType |
Standard
|
Pages |
22
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This British Standard specifies requirements and test methods for the construction and performance of non-armoured, single core non-sheathed cables which: have a thermosetting insulation of rated voltage 450/750V; provide resistance to fire (circuit integrity), including mechanical shock, as measured by performance in a standard test; emit limited amounts of smoke and corrosive gases when burned as measured by a standard test; are flame retardant; and are primarily, but not exclusively, intended for use inside metal enclosures such as steel conduit. This British Standard is applicable to cables for use in fixed installations in industrial areas, buildings and similar applications, where maintenance of power supply during a fire is required for a defined period of time. NOTE1 Attention is drawn to the fact that the ability of a given cable to meet the test in this standard refers only to the test conditions stated, and the level of performance achieved in a particular installation can be influenced by actual installation conditions. The insulation and other components are suitable to permit operation of the cables at a maximum sustained conductor temperature of 90°C and for a maximum short-circuit conductor temperature of 250°C (for a maximum of 5s). NOTE2 AnnexA gives recommendations for the selection, installation and operation of cables. AnnexB gives notes on type tests.
BS 5266-1:2016 | Emergency lighting Code of practice for the emergency lighting of premises |
BS EN 61034-2 : 2005 | MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS PART 2: TEST PROCEDURE AND REQUIREMENTS |
BS EN 50565-1:2014 | Electric cables. Guide to use for cables with a rated voltage not exceeding 450/750 V (U<sub>0</sub>/U) General guidance |
BS EN 60811-502:2012 | Electric and optical fibre cables. Test methods for non-metallic materials Mechanical tests. Shrinkage test for insulations |
BS EN 60332-1-2 : 2004 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004) |
BS EN 60228:2005 | Conductors of insulated cables |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS EN 50395 : 2005 | ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
BS 8519:2010 | Selection and installation of fire-resistant power and control cable systems for life safety and fire-fighting applications. Code of practice |
BS EN 62230 : 2007 | ELECTRIC CABLES - SPARK-TEST METHOD |
IEC 60050-461:2008 | International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables |
BS EN 50363-5 : 2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 5: HALOGEN-FREE, CROSS-LINKED INSULATING COMPOUNDS |
IEC 60331-3:2009 | Tests for electric cables under fire conditions - Circuit integrity - Part 3: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV tested in a metal enclosure |
BS EN 50396 : 2005 | NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
BS EN 60754-1:2014 | Test on gases evolved during combustion of materials from cables Determination of the halogen acid gas content |