BS 7922:2004
Current
The latest, up-to-date edition.
Electric cables. Fluid-filled, paper- and PPL-insulated, metal-sheathed cables and accessories for alternating voltages up to and including 400 kV (Um = 420 kV). Requirements and test methods
Hardcopy , PDF
English
08-04-2004
Committees responsible
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Voltage designation
5 Characteristics of cables and accessories
6 Test categories, frequency and conditions
7 Routine tests on cables
8 Sample tests on cables
9 Routine tests on accessories
10 Sample tests on accessories
11 Type tests on cables and accessories
12 Non-electrical type tests on cables
13 Non-electrical type tests on accessories
14 Tests and requirements for direct reading pressure gauges
15 Tests after installation
16 Tests on ancillary equipment
Annex A (informative) Methods of heating cable samples
Annex B (informative) Pressure drop
Bibliography
Describes tests and requirements for radial field, fluid-filled, paper or polypropylene paper laminate (PPL) insulated metal-sheathed cables and their accessories, which operate with a minimum static pressure of between 20 kPa (0.2 bar) and 300 kPa (3.0 bar) inclusive, a maximum static pressure of not more than 800 kPa (8.0 bar) and a minimum transient pressure of not less than 20 kPa (0.2 bar).
Committee |
GEL/20/16
|
DevelopmentNote |
Supersedes 95/215974 DC. (08/2004) Reviewed and confirmed by BSI, December 2009. (11/2009)
|
DocumentType |
Standard
|
Pages |
46
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This British Standard specifies tests and requirements for radial field, fluid-filled, paper or polypropylene paper laminate (PPL) insulated metal-sheathed cables and their accessories, which operate with a minimum static pressure of between 20 kPa (0.2 bar) and 300 kPa (3.0 bar) inclusive, a maximum static pressure of not more than 800 kPa (8.0 bar) and a minimum transient pressure of not less than 20 kPa (0.2 bar)1).
NOTE The cables in this British Standard are specifically excluded from the scope of the Pressure Equipment Directive.
It also specifies tests for cables and accessories with maximum static pressures exceeding 800 kPa (8.0 bar).
This British Standard is applicable to cables and accessories intended for use in systems with nominal voltages not exceeding 400 kV between phases.
Standards | Relationship |
HD 633 S1:1997 | Identical |
IEC 60060-2:2010 | High-voltage test techniques - Part 2: Measuring systems |
BS 4727-2:GRP08(1994) : 1994 | GLOSSARY OF ELECTROTECHNICAL, POWER, TELECOMMUNICATION, ELECTRONICS, LIGHTING AND COLOUR TERMS - TERMS PARTICULAR TO POWER ENGINEERING - ELECTRIC CABLES |
IEC 60228:2004 | Conductors of insulated cables |
IEC 60287-2-1:2015 RLV | Electric cables - Calculation of the current rating - Part 2-1: Thermal resistance - Calculation of thermal resistance |
IEC TS 60859:1999 | Cable connections for gas-insulated metal-enclosed switchgear for rated voltages of 72,5 kV and above - Fluid-filled and extruded insulation cables - Fluid-filled and dry type cable-terminations |
BS 7912:2001 | Power cables with XLPE insulation and metallic sheath, and their accessories, for rated voltages from 66 kV (<i>U</i><sub>m</sub>=72.5 kV) to 132kV (<i>U</i><sub>m</sub>=145kV). Requirements and test methods |
IEC 60554-2:2001 | Cellulosic papers for electrical purposes - Part 2: Methods of test |
IEC 60230:1966 | Impulse tests on cables and their accessories |
BS EN 60068-2-1:2007 | Environmental testing Tests. Test A. Cold |
BS EN 50062:1992 | Specification for ceramic pressurized hollow insulators for high-voltage switchgear and controlgear |
BS 6346:1997 | Electric cables. PVC insulated, armoured cables for voltages of 600/1000 V and 1900/3300 V |
IEC 60183:2015 | Guidance for the selection of high-voltage A.C. cable systems |
BS 228:1994 | Specification for short-pitch transmission precision roller chains and chain wheels |
BS EN 60068-2-2:2007 | Environmental testing Tests. Test B. Dry heat |
IEC 60229:2007 | Electric cables - Tests on extruded oversheaths with a special protective function |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60507:2013 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.