BS 7629-1:2015+A1:2019
Current
The latest, up-to-date edition.
Electric cables. Specification for 300/500 V fire resistant, screened, fixed installation cables having low emission of smoke and corrosive gases when affected by fire Multicore cables
Hardcopy , PDF
English
06-20-2019
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Voltage designation and fire resistance categories
5 Conductors and drain wire
6 Insulation
7 Identification of cores
8 Laying-up
9 Screen
10 Sheath
11 Cable marking and additional information
12 Schedule of tests
13 Test conditions
14 Routine tests
15 Sample tests
16 Type tests
Annexes
Annex A (informative) - Guide to selection, installation
and operation
Annex B (normative) - Method of test for continuity of
tinned coatings of wires
Annex C (normative) - Method of test for voltage withstand
Annex D (normative) - Method of test for bending
characteristics
Annex E (normative) - Method of test for resistance to impact
Annex F (normative) - Method of test for shrinkage of sheath
on cable during heat treatment
Annex G (informative) - Notes on type tests
Bibliography
Defines requirements and test methods for the construction and performance of cables which: - have thermosetting insulation and a rated voltage of 300/500 V; - provide resistance to fire (circuit integrity), including with mechanical shock and with water, as measured by performance in a standard test or tests; - emit limited amounts of smoke and corrosive gases when burned as measured by a standard test; and - are primarily intended for use in emergency lighting, fire detection and fire alarm system circuits.
Committee |
GEL/20/17
|
DocumentType |
Standard
|
ISBN |
978 0 580 99630 6
|
Pages |
34
|
ProductNote |
This standard also refers to Electricity Safety, Quality and Continuity Regulations 2002,
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This British Standard specifies requirements and test methods for the construction and performance of cables which:
have thermosetting insulation and a rated voltage of300/500V;
provide resistance to fire (circuit integrity), including with mechanical shock and with water, as measured by performance in a standard test or tests;
emit limited amounts of smoke and corrosive gases when burned as measured by a standard test; and
are primarily intended for use in emergency lighting, fire detection and fire alarm system circuits.
The circuit integrity performance under fire conditions is assessed on the basis of tests which measure resistance to fire with mechanical impact and water spray (Categories: Standard30, Standard60and Enhanced120).
NOTE1 BS5266‑1and BS5839‑1give recommendations and guidance on the factors to be taken into account in the planning, design, installation, commissioning and maintenance of emergency lighting, fire detection and fire alarm systems for buildings, respectively.
It is applicable to2‑core,3‑core and4‑core circular cables with an uninsulated full-size circuit protective conductor (CPC), and7‑core,12‑core and19‑core circular multicore auxiliary cables with an uninsulated drain wire of not less than 0.5mm2. All cables contain a metallic layer, which provides electrostatic screening.
The cables are suitable for operation at a maximum sustained conductor temperature of70°C and for a maximum short‑circuit conductor temperature of250°C (for a maximum period of5s).
NOTE2 AnnexA gives recommendations for the selection, installation and operation of cables, AnnexB gives the method of test for continuity of tinned coating of wires, AnnexC gives the method of test for voltage withstand, AnnexD gives the method of test for bending characteristics, AnnexE gives the method of test for resistance to impact, AnnexF gives the method of test for shrinkage of sheath and AnnexG gives notes on type tests.
BS EN 60811-506:2012 | Electric and optical fibre cables. Test methods for non-metallic materials Mechanical tests. Impact test at low temperature for insulations and sheaths |
BS EN 61034-2 : 2005 | MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS PART 2: TEST PROCEDURE AND REQUIREMENTS |
BS 5266-1:2011 | Emergency lighting Code of practice for the emergency escape lighting of premises |
BS EN 60811-502:2012 | Electric and optical fibre cables. Test methods for non-metallic materials Mechanical tests. Shrinkage test for insulations |
BS EN 50200:2015 | Method of test for resistance to fire of unprotected small cables for use in emergency circuits |
BS EN 61034-1 : 2005 | MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS - PART 1: TEST APPARATUS |
BS 5839-1:2013 | Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises |
BS EN ISO/IEC 17025:2017 | General requirements for the competence of testing and calibration laboratories |
BS EN 60332-1-2 : 2004 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004) |
BS EN 60228:2005 | Conductors of insulated cables |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS EN 60079-14:2014 | Explosive atmospheres Electrical installations design, selection and erection |
BS 8434-2(2003) : 2003 | METHODS OF TEST FOR ASSESSMENT OF THE FIRE INTEGRITY OF ELECTRIC CABLES - PART 2: TEST FOR UNPROTECTED SMALL CABLES FOR USE IN EMERGENCY CIRCUITS - BS EN 50200 WITH A 930 DEGREE C FLAME AND WITH WATER SPRAY |
BS EN 50395 : 2005 | ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
BS 8519:2010 | Selection and installation of fire-resistant power and control cable systems for life safety and fire-fighting applications. Code of practice |
BS EN 62230 : 2007 | ELECTRIC CABLES - SPARK-TEST METHOD |
IEC 60050-461:2008 | International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables |
BS EN 50363-1:2005 | Insulating, sheathing and covering materials for low voltage energy cables Cross-linked elastomeric insulating compounds |
BS EN 50363-5 : 2005 | INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 5: HALOGEN-FREE, CROSS-LINKED INSULATING COMPOUNDS |
BS EN 50396 : 2005 | NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
BS EN 60754-1:2014 | Test on gases evolved during combustion of materials from cables Determination of the halogen acid gas content |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.