Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Handing
5 Components
6 Appearance and finish
7 Fabrication
8 Glazing
9 Use, cleaning and maintenance
10 Security
11 Safety in case of fire
12 Safety in use
13 Weathertightness
14 Operation and strength characteristics
15 Hygiene, health and the environment
16 Acoustic performance
17 Energy conservation
18 Marking
Annexes
Annex A (informative) Guidance on the evaluation of
        conformity
Annex B (informative) Durability and recycling
Annex C (normative) Specification for handing
Annex D (normative) Weld test
Annex E (normative) Mechanical joint tests (mullion
        and transom joints)
Bibliography

Defines requirements for the design, fabrication and performance of windows and glazed doorsets made from PVC-U extruded hollow profiles.

Committee
B/538/1
DevelopmentNote
Supersedes BS 7412(2002). Supersedes 06/30143171 DC. (04/2007)
DocumentType
Standard
Pages
32
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

This British Standard specifies requirements for the design, fabrication and performance of windows and glazed doorsets made from PVC-U extruded hollow profiles. This British Standard applies to windows and doorsets manufactured from PVC-U hollow profiles incorporating fusion welded corner joints. It applies to windows and doors fabricated into frames in a factory, to be installed vertically (within 15°) into the external face of buildings, as single or multi-light units, in coupled assemblies when appropriate, of the following types: windows: hinged: side-hung (open in or out), top-hung (open out), bottom-hung (open in), tilt and turn or turn before tilt; projecting: side-hung (open in or open out) and top-hung (open out or reversible); pivoted: horizontal and vertical (hung centrally or off-centre) including reversible; sliding: horizontal and vertical; side-hung: fully reversible; fixed light; doors: single leaf single-swing doors with or without side lights and top panels; double leaf single-swing doors with or without side lights and top panels. It is applicable to assemblies in which any frame member is not longer than 3m. It does not apply to curtain walls that span across horizontal structural members of floors but is applicable to windows within a curtain walling system. It is applicable to assemblies up to the point of installation. NOTE Guidance on the evaluation of conformity is given in AnnexA. Guidance on durability and recycling is given in AnnexB.

ISO 7724-1:1984 Paints and varnishes Colorimetry Part 1: Principles
BS EN 1027:2016 Windows and doors. Water tightness. Test method
BS EN 10327:2004 Continuously hot-dip coated strip and sheet of low carbon steels for cold forming. Technical delivery conditions
BS EN 13024-1:2011 Glass in building. Thermally toughened borosilicate safety glass Definition and description
BS EN 14179-2:2005 Glass in building. Heat-soaked thermally-toughened soda lime silicate safety glass Evaluation of conformity/product standard
ISO 6504-3:2006 Paints and varnishes Determination of hiding power Part 3: Determination of contrast ratio of light-coloured paints at a fixed spreading rate
89/106/EEC : 1988 COUNCIL DIRECTIVE OF 21 DECEMBER 1988 ON THE APPROXIMATION OF LAWS, REGULATIONS AND ADMINISTRATIVE PROVISIONS OF THE MEMBER STATES RELATING TO CONSTRUCTION PRODUCTS
BS EN 13141-1:2004 Ventilation for buildings. Performance testing of components/products for residential ventilation Externally and internally mounted air transfer devices
BS EN 14321-2:2005 Glass in building. Thermally toughened alkaline earth silicate safety glass Evaluation of conformity/Product standard
ISO 7724-2:1984 Paints and varnishes Colorimetry Part 2: Colour measurement
BS EN 12519:2004 Windows and pedestrian doors. Terminology
BS EN 1863-1:2011 Glass in building. Heat strengthened soda lime silicate glass Definition and description
BS EN 10088-2:2014 Stainless steels Technical delivery conditions for sheet/plate and strip of corrosion resisting steels for general purposes
BS 3900-D9:1986 Methods of test for paints. Optical tests on paint films Determination of colour and colour difference: measurement
BS 6375-1:2004 Performance of windows and doors Classification for weathertightness and guidance on selection and specification
BS 8000-7:1990 Workmanship on building sites Code of practice for glazing
BS EN 14351-1 : 2006 WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 1: WINDOWS AND EXTERNAL PEDESTRIAN DOORSETS
BS EN 14178-2:2004 Glass in building. Basic alkaline earth silicate glass products Evaluation of conformity/Product standard
BS EN 12608:2003 Unplasticized polyvinylchloride (PVC-U) profiles for the fabrication of windows and doors. Classification, requirements and test methods
BS EN 14178-1:2004 Glass in building. Basic alkaline earth silicate glass Float glass
BS EN 12150-1:2015 Glass in building. Thermally toughened soda lime silicate safety glass Definition and description
BS EN 755-9:2016 Aluminium and aluminium alloys. Extruded rod/bar, tube and profiles Profiles, tolerances on dimensions and form
BS 6100-1.3.6:1991 Glossary of building and civil engineering terms. General and miscellaneous. Parts of construction works Jointing products, builders\' hardware and accessories
BS 6100-1.6:1985 Glossary of building and civil engineering terms. General and miscellaneous Persons
BS 7950:1997 Specification for enhanced security performance of windows for domestic applications
BS EN 514:2000 Unplasticized polyvinylchloride (PVC-U) profiles for the fabrication of windows and doors. Determination of the strength of welded corners and T-joints
BS EN 1670:2007 Building hardware. Corrosion resistance. Requirements and test methods
BS EN 13142:2013 Ventilation for buildings. Components/products for residential ventilation. Required and optional performance characteristics
BS 6375-2:1987 Performance of windows Specification for operation and strength characteristics
BS PAS 24-1(1999) : 1999 AMD 16981 ENHANCED SECURITY PERFORMANCE REQUIREMENTS FOR DOOR ASSEMBLIES - PART 1: SINGLE AND DOUBLE LEAF, HINGED EXTERNAL DOOR ASSEMBLIES TO DWELLINGS
BS 8213-4:2007 Windows, doors and rooflights Code of practice for the survey and installation of windows and external doorsets
BS EN 14321-1:2005 Glass in building. Thermally toughened alkaline earth silicate safety glass Definition and description
BS 6100-1:2004 Building and civil engineering. Vocabulary General terms
BS EN 515:2017 Aluminium and aluminium alloys. Wrought products. Temper designations
BS EN 485-2:2013 Aluminium and aluminium alloys. Sheet, strip and plate Mechanical properties
BS 3900-D10:1986 Methods of test for paints Determination of colour and colour difference: calculation
BS EN ISO 105-A01:2010 Textiles. Tests for colour fastness General principles of testing
BS ISO 6707-1:2014 Buildings and civil engineering works. Vocabulary General terms
BS EN 12211:2016 Windows and doors. Resistance to wind load. Test method
BS 3900-D8:1986 Methods of test for paints. Optical tests on paint films Determination of colour and colour difference: principles
BS EN 12337-2:2004 Glass in building. Chemically strengthed soda lime silicate glass Evaluation of conformity/Product standard
BS EN 1863-2:2004 Glass in building. Heat strengthened soda lime silicate glass Evaluation of conformity. Product standard
BS EN 12337-1:2000 Glass in building. Chemically strengthened soda lime silicate glass Definition and description
BS EN 13024-2:2004 Glass in building. Thermally toughened borosilicate safety glass Evaluation of conformity/Product standard
BS EN 14179-1:2005 Glass in building. Heat-soaked thermally-toughened soda lime silicate safety glass Definition and description
BS EN 12150-2:2004 Glass in building. Thermally toughened soda lime silicate safety glass Evaluation of conformity/Product standard
BS EN ISO 4042:2000 Fasteners. Electroplated coatings
BS EN 14449:2005 Glass in building. Laminated glass and laminated safety glass. Evaluation of conformity/product standard

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.