• There are no items in your cart

BS 7273-3:2000

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Code of practice for the operation of fire protection measures Electrical actuation of pre-action sprinkler systems

Available format(s)

Hardcopy , PDF

Superseded date

01-31-2008

Superseded by

BS 7273-3:2008

Language(s)

English

Published date

10-15-2000

US$184.93
Excluding Tax where applicable

Committees responsible
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 System design
5 Fire detection
6 System interface
7 Power supplies
8 Wiring
9 Servicing
Annex A (informative) Example of an arrangement for separate
                      fire alarm and pre-action control
                      and indicating equipment
Annex B (informative) Example of an arrangement for fire
                      detectors and pre-action valve-set
                      connected to and monitored by a single
                      control panel
Annex C (informative) Example of an arrangement for any
                      coincidence logic provided at fire
                      alarm control and indicating equipment
Annex D (informative) Example of an arrangement for any
                      coincidence logic provided at pre-
                      action control and indicating equipment
Figure 1 - Typical logic gate depiction of pre-action systems
Figure A.1 - Example of an arrangement for separate fire
             alarm and pre-action control and indicating
             equipment
Figure B.1 - Example of an arrangement for fire detectors and
             pre-action valve-set connected to and monitored
             by a single control panel
Figure C.1 - Example of an arrangement for any coincidence
             logic provided at fire alarm control and
             indicating equipment
Figure D.1 - Example of an arrangement for any coincidence
             logic provided at pre-action control and
             indicating equipment
Table 1 - Maximum areas of coverage per point-type smoke
          detector to operate pre-action sprinkler
          installations in still air conditions for
          coincidence and non-coincidence connection fire
          detection systems

Makes recommendations for installation, design, servicing and operation of electrical equipment used for the actuation of pre-action sprinkler systems.

Committee
FSH/12/4
DevelopmentNote
Supersedes 99/540022 DC. (12/2002)
DocumentType
Standard
Pages
16
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

BS 6266:2002 Code of practice for fire protection for electronic equipment installations
BS 5454:2000 Recommendations for the storage and exhibition of archival documents
PD 6686:2006 Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries

BS EN 60651:1994 Specification for sound level meters
BS 5839-5:1988 Fire detection and alarm systems for buildings Specification for optical beam smoke detectors
BS 5839-1:1988 Fire detection and alarm systems for buildings Code of practice for system design, installation and servicing
BS 7671:1992 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS
BS EN 54-4:1998 Fire detection and fire alarm systems Power supply equipment
BS EN 54-2 : 1998 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.