BS 7117-1:1991
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Metering pumps and dispensers to be installed at filling stations and used to dispense liquid fuel Specification for construction
Hardcopy , PDF
10-21-2004
BS EN 13617-2:2012
BS EN 13012:2012
BS EN 13617-1:2012
BS EN 13617-1:2004+A1:2009
BS EN 13617-2:2004
BS EN 13012:2001
English
01-06-2003
Committees responsible
Foreword
Introduction
1 Scope
2 Definitions
3 Classification of fuels
4 Classification of hazardous areas
5 Classification of mode of operation of dispensing
equipment
6 Classification of pump facilities
7 Classification of vapour barriers
8 Construction and performance
9 Marking and labelling
10 Manufacturer's instructions
Appendix
A Bibliography
Figures
Publication(s) referred to
Requirements for dispensing, under pressure, liquid fuels which are flammable liquids having flash points not exceeding 100°C. Particular attention is given to mechanical, hydraulic, and electrical equipment installed within, or mounted on the metering pump/dispenser housing.
Committee |
PVE/393
|
DevelopmentNote |
Supersedes 02/705248 DC, 90/30640 DC, 96/208377 DC and BS 7117-1(1989) (01/2003)
|
DocumentType |
Standard
|
Pages |
36
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
BS 3955:1986 | Specification for electrical controls for household and similar general purposes |
BS 3395:1989 | Specification for electrically bonded rubber hoses and hose assemblies for dispensing petroleum based fuels |
BS 5501-9:1982 | Electrical apparatus for potentially explosive atmospheres Specification for intrinsically safe electrical systems \'i\' |
BS 5501-4:1977 | Electrical apparatus for potentially explosive atmospheres Powder filling \'q\' |
BS 7117-3:1991 | Metering pumps and dispensers to be installed at filling stations and used to dispense liquid fuel Guide to maintenance after installation |
BS 5501-7:1977 | Electrical apparatus for potentially explosive atmospheres Intrinsic safety \'i\' |
BS 5419:1977 | Specification for air-break switches, air-break disconnectors, air-break switch disconnectors and fuse-combination units for voltages up to and including 1000 V a.c. and 1200 V d.c. |
BS 7671(2001) : 2001 AMD 14905 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS |
BS 5501-6:1977 | Electrical apparatus for potentially explosive atmospheres Increased safety \'e\' |
BS 5501-1:1977 | Electrical apparatus for potentially explosive atmospheres General requirements |
BS 5501-5:1977 | Electrical apparatus for potentially explosive atmospheres Flameproof enclosure \'d\' |
BS 889:1965 | Specification for flameproof electric lighting fittings |
BS 4683-1:1971 | Specification for electrical apparatus for explosive atmospheres Classification of maximum surface temperatures |
BS EN 13012:2012 | Petrol filling stations. Construction and performance of automatic nozzles for use on fuel dispensers |
BS 5501-8:1988 | Electrical apparatus for potentially explosive atmospheres Encapsulation \'m\' |
BS 5501-2:1977 | Electrical apparatus for potentially explosive atmospheres Oil immersion \'o\' |
BS 6941:1988 | Specification for electrical apparatus for explosive atmospheres with type of protection N |
BS 5501-3:1977 | Electrical apparatus for potentially explosive atmospheres Pressurized apparatus \'p\' |
BS 7117-2:1991 | Metering pumps and dispensers to be installed at filling stations and used to dispense liquid fuel Guide to installation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.