BS 6880-1:1988
Current
The latest, up-to-date edition.
Code of practice for low temperature hot water heating systems of output greater than 45 kW Fundamental and design considerations
Hardcopy , PDF
English
02-29-1988
Foreword
Committees responsible
Section one. General
1.1 Scope
1.2 Definitions
Section two. Fundamental considerations
2.1 General
2.2 Comfort factors
2.3 Application factors
2.4 Statutory, structural and safety factors
2.5 Energy conservation and energy management
2.6 Quality and reliability
Section three. Design considerations
3.1 Types of systems
3.2 Basis of design
3.3 Energy conversion subsystem design
3.4 Distribution subsystem design
3.5 Corrosion control and water treatment
3.6 Thermal insulation
3.7 Plant room ventilation
3.8 Automatic controls
3.9 Electrical requirements
3.10 Noise and vibration
3.11 General layout and operational facilities
Appendix
A Bibliography
Tables
1 Recommended design values for resultant
temperature, tc (heating season)
2 Levels of relative humidity, for an internal
temperature of 21 deg C, at which condensation
will occur at various outside temperatures
3 Air temperatures for educational accommodation
4 Recommended resultant temperatures for industrial
work
5 Recommended temperatures for storage spaces
6 Recommended minimum oil storage and handling
temperatures for classes E, F and G fuel oils
7 Typical ranges of excess air
8 Thermal expansion characteristics of piping
materials
Figures
1 Typical 24 h load profile and temperature decay
curve (based on 9 am to 5 pm occupancy)
2 Principal flue types
3 Simplified representation of principal system
temperature relationships
4 Principal circuit arrangements
5 Typical air vent arrangements
6 Pump and feed location
7 Vent arrangement for multiple boilers
8 Typical multiple boiler control arrangements
9 HWS control
10 Location of sensors in pipes and ducts
Requirements which need to be taken into account in the design of open-vented or sealed systems.
Committee |
RHE/2
|
DevelopmentNote |
Supersedes 85/70687 DC and BS CP341.300-307(1956) (09/2005) Reviewed and confirmed by BSI, December 2012. (11/2012)
|
DocumentType |
Standard
|
Pages |
88
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This Part of BS 6880 gives recommendations regarding the fundamental considerations and the design considerations which need to be taken into account in the design of low temperature hot water (see 1.2.1) heating systems of output greater than 45 kW, open vented or sealed. It is primarily intended for use by building owners, building managers, installers and associated professionals. It is not intended to serve as a detailed design guide (see foreword).
The recommendations recognize the need to optimize the use of energy, reduce hazards and minimize effects detrimental to the environment.
Solar heating is outside the scope of this code.
NOTE The titles of the British Standards publications referred to in this standard are listed on the inside back cover. References in the text to other publications are identified in the text by numbers in square brackets, and are listed in Appendix A.
BS 7478:1991 | Guide to selection and use of thermostatic radiator valves |
BS 7350:1990 | Specification for double regulating globe valves and flow measurement devices for heating and chilled water systems |
BS 6644(2005) : 2005 | SPECIFICATION FOR INSTALLATION OF GAS-FIRED HOT WATER BOILERS OF RATED INPUTS BETWEEN 70 KW (NET) AND 1.8 MW (NET) (2ND AND 3RD FAMILY GASES) |
BS 6644:2011 | Specification for the installation and maintenance of gas-fired hot water boilers of rated inputs between 70 kW (net) and 1.8 MW (net) (2nd and 3rd family gases) |
BS 6880-2:1988 | Code of practice for low temperature hot water heating systems of output greater than 45 kW Selection of equipment |
BS 6880-3:1988 | Code of practice for low temperature hot water heating systems of output greater than 45 kW Installation, commissioning and maintenance |
11/30229801 DC : 0 | BS 6644 - SPECIFICATION FOR THE INSTALLATION OF GAS-FIRED HOT WATER BOILERS OF RATED INPUTS BETWEEN 70 KW (NET) AND 1.8 MW (NET) (2ND AND 3RD FAMILY GASES) |
EN 12828:2012+A1:2014 | Heating systems in buildings - Design for water-based heating systems |
BS EN 12828 : 2012 | HEATING SYSTEMS IN BUILDINGS - DESIGN FOR WATER-BASED HEATING SYSTEMS |
BS CP413(1973) : AMD 3345 | CODE OF PRACTICE FOR DUCTS FOR BUILDING SERVICES |
BS 526:1961 | Definitions of the calorific value of fuels |
BS 5986:1980 | Specification for electrical safety and performance of gas fired space heating appliances with inputs 60 kW to 2 MW |
BS 6644:1986 | Specification for installation of gas-fired hot water boilers of rated inputs between 60 kW and 2 MW (2nd and 3rd family gases) |
BS 4814:1976 | Specification for expansion vessels using an internal diaphragm, for sealed hot water heating systems |
BS 4508-3:1977 | Thermally insulated underground pipelines General requirements for cased systems without air gap |
BS 749:1969 | Specification for underfeed stokers |
BS 5854:1980 | Code of practice for flues and flue structures in buildings |
BS 5440-2:1976 | Installation of flues and ventilation for gas appliances of rated input not exceeding 60 kW (1st, 2nd and 3rd family gases). Air supply |
BS 5486-1:1986 | Low-voltage switchgear and controlgear assemblies. Specification for type-tested and partially type-tested assemblies (general requirements) |
BS 4999-20:1972 | Specification for general requirements for rotating electrical machines Classification of types of enclosure |
BS 4434-1:1980 | Specification for requirements for refrigeration safety. General |
BS 4086:1966 | Recommendations for maximum surface temperatures of heated domestic equipment |
BS 4508-4:1977 | Thermally insulated underground pipelines Specific testing and inspection requirements for cased systems without air gap |
BS 6880-2:1988 | Code of practice for low temperature hot water heating systems of output greater than 45 kW Selection of equipment |
BS 5925:1980 | Code of practice for design of buildings: ventilation principles and designing for natural ventilation |
BS 5440-1:1978 | Installation of flues and ventilation for gas appliances of rated input not exceeding 60 kW (1st, 2nd and 3rd family gases). Flues |
BS 5978-2:1983 | Safety and performance of gas-fired hot water boilers (60 kW to 2 MW input). Specification for additional requirements for boilers with atmospheric burners |
BS CP3000(1955) : 1955 | CODE OF PRACTICE ON THE INSTALLATION AND MAINTENANCE OF UNDERFEED STOKERS |
BS 6700:1987 | Specification for design, installation, testing and maintenance of services supplying water for domestic use within buildings and their curtilages |
BS 4434-2:1976 | Specification. Requirements for refrigeration safety. Particular requirements for small refrigerating systems for use in household appliances |
BS 6380:1983 | Guide to low temperature properties and cold weather use of diesel fuels and gas oils (classes A1, A2 and D of BS 2869) |
BS 5304:1988 | Code of practice for safety of machinery |
BS CP3009(1970) : AMD 3340 | THERMALLY INSULATED UNDERGROUND PIPING SYSTEMS |
BS 5885(1980) : AMD 5019 | INDUSTRIAL GAS BURNERS, OF INPUT RATING 60 KW AND ABOVE |
BS 1523(1954) : LATEST | |
BS 3323:1978 | Glossary of coal terms |
BS 5500:1988 | Specification for unfired fusion welded pressure vessels |
BS 5422:1977 | Specification for the use of thermal insulating materials |
BS 4941-3:1977 | Specification for motor starters for voltages up to and including 1000 V a.c. and 1200 V d.c. Rheostatic rotor starters |
BS 5410-2:1978 | Code of practice for oil firing Installations of 45 kW and above output capacity for space heating, hot water and steam supply services |
BS 5970:1981 | Code of practice for thermal insulation of pipework and equipment (in the temperature range -100°C to +870°C) |
BS 5720:1979 | Code of practice for mechanical ventilation and air conditioning in buildings |
BS 3533:1981 | Glossary of thermal insulation terms |
BS 4941-4:1977 | Specification for motor starters for voltages up to and including 1000 V a.c. and 1200 V d.c. Reduced voltage a.c. starters, two-step auto-transformer starters |
BS 2048-1:1961 | Specification for dimensions of fractional horse-power motors Dimensions of motors for general use |
BS 4941-2:1977 | Specification for motor starters for voltages up to and including 1000 V a.c. and 1200 V d.c. Reduced voltage a.c. starters, star delta starters |
BS 6129-1:1981 | Code of practice for the selection and application of bellows expansion joints for use in pressure systems. Metallic bellows expansion joints |
BS 5449-1:1977 | Code of practice for central heating for domestic premises. Forced circulation hot water systems |
BS 779:1976 | Specification. Cast iron boilers for central heating and indirect hot water supply (44 kW rating and above) |
BS 853:1981 | Specification for calorifiers and storage vessels for central heating and hot water supply |
BS 5233:1986 | Glossary of terms used in metrology (incorporating BS 2643) |
BS 2869:1983 | Specification for fuel oils for oil engines and burners for non-marine use |
BS 6880-3:1988 | Code of practice for low temperature hot water heating systems of output greater than 45 kW Installation, commissioning and maintenance |
BS 4508-2(1973) : LATEST | ASBESTOS CEMENT CASED SYSTEM WITH AIR GAP |
BS 5643:1984 | Glossary of refrigeration, heating, ventilating and air-conditioning terms |
BS 4941-1:1979 | Specification for motor starters for voltages up to and including 1000 V a.c. and 1200 V d.c. Direct-on-line (full voltage) a.c. starters |
BS 4999-101:1987 | General requirements for rotating electrical machines Specification for rating and performance |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.