• There are no items in your cart

BS 6622:1999

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Specification for cables with extruded cross-linked polyethylene or ethylene propylene rubber insulation for rated voltages from 3.8/6.6 kV up to 19/33 kV

Available format(s)

Hardcopy , PDF

Superseded date

03-30-2007

Language(s)

English

Published date

02-26-2002

US$359.44
Excluding Tax where applicable

Committees responsible
Foreword
Specification
1 Scope
2 Normative references
3 Definitions
4 Voltage designation
5 Conductors
6 Conductor screen
7 Insulation
8 Insulation screen
9 Laying-up
10 Armour
11 Oversheath
12 Marking
13 Sealing and drumming
14 Dimensions
15 Schedule of tests
16 Test conditions
17 Routine tests
18 Sample tests
19 Type tests - Materials
20 Type tests - Electrical
Annexes
A (informative) Recommendations for the selection of cables
B (informative) Information to be provided with the
    enquiry or order
C (informative) Recommendations for the installation of
    cables
D (informative) Guidance on the scope of type tests
E (normative) Partial discharge test
F (normative) Thickness measurements
G (normative) Method of measuring resistivity of extruded
    semi-conducting conductor and insulation screens
H (normative) Impulse voltage test
J (informative) Guide to use
Bibliography
Figure G.1 Test piece and arrangement of electrodes for
             measurement of resistivity of conductor screen
             of circular core
Figure G.2 Test piece and arrangement of electrodes for
             measurement of resistivity of insulation screen
             of circular core
Figure G.3 Arrangement of test piece, electrodes and
             insulating strips for measurement of resistivity
             of conductor and insulation screens of
TABLES
1 - Dimensions of shaped solid aluminium conductors
2 - Single-core cables 3.8/6.6 (7.2) kV
3 - Three-core cables 3.8/6.6 (7.2) kV
4 - Single-core cables 6.35/11 (12) kV
5 - Three-core cables 6.35/11 (12) kV
6 - Single-core cables 8.7/15 (17.5) kV
7 - Three-core cables 9.7/15 (17.5) kV
8 - Single-core cables 12.7/22 (24) kV
9 - Three-core cables 12.7/22 (22) kV
10 - Single-core cables 19/33 (36) kV
11 - Three-core cables 19/33 (36) kV
12 - Schedule of tests
13 - Tolerances on temperature values
14 - D.C. resistance of copper wire screen
15 - Voltage for partial discharge test
16 - Voltage for test on complete cable
17 - Number of sample tests
18 - Hot set test conditions and requirements
19 - Four hour voltage test
20 - Cross-linked polyethylene (XLPE) and ethylene propylene rubber
     compound (EPR) insulation
21 - Mass of zinc coating
22 - Compatibility requirements
23 - Tan in relation to voltage
24 - Tan in relation to temperature
25 - Voltage for impulse voltage test
A.1 - Selection of cables for three-phase a.c. systems
C.1 - Bending radius during installation
C.2 - Bending radius with cable adjacent to joints or terminations
C.3 - Voltage test after installation

Specifies requirements for construction and testing of cables with thermosetting insulation for rated voltages from 3.8/6.6 (7.2) kV up to 19/33 (36) kV, for use in fixed industrial installations and buildings.

Committee
GEL/20/16
DevelopmentNote
Supersedes BS 6622(1991), 97/205747 DC and 99/243586 DC (03/2002)
DocumentType
Standard
Pages
56
PublisherName
British Standards Institution
Status
Superseded

IEC 60038:2009 IEC standard voltages
BS 4727-2:GRP08(1986) : 1986 GLOSSARY OF ELECTROTECHNICAL POWER TELECOMMUNICATION ELECTRONICS LIGHTING AND COLOUR TERMS - TERMS PARTICULAR TO POWER ENGINEERING - ELECTRIC CABLE TERMINOLOGY
BS EN 60811-1-1:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Measurement of thickness and overall dimensions. Tests for determining the mechanical properties - Section 1: Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
BS EN 60811-1-3:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Methods for determining the density. Water absorption tests. Shrinkage test
BS EN 10244-2:2009 Steel wire and wire products. Non-ferrous metallic coatings on steel wire Zinc or zinc alloy coatings
BS EN 60060-2:1995 High-voltage test techniques Measuring systems
IEC 60183:2015 Guidance for the selection of high-voltage A.C. cable systems
BS 7655-4.2:1993 Specification for insulating and sheathing materials for cables. PVC sheathing compounds General application
BS EN 60811-2-1:1998 Insulating and sheathing materials of electric cables. Common test methods. Methods specific to elastomeric compounds Methods specific to elastomeric compounds. Ozone resistance, hot set and mineral oil immersion tests
BS EN 50265-2-1:1999 Common test methods for cables under fire conditions. Test for resistance to vertical flame propagation for a single insulated conductor or cable. Procedures 1 kW pre-mixed flame - 1 kW pre-mixed flame
BS EN 60811-1-2:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Thermal ageing methods
BS 358:1960 Method for the measurement of voltage with sphere-gaps (one sphere earthed)
BS 7655-10.1(1997) : 1997 SPECIFICATION FOR INSULATING AND SHEATHING MATERIALS FOR CABLES - POLYETHYLENE SHEATHING COMPOUNDS - THERMOPLASTIC MEDIUM DENSITY POLYETHYLENE (MDPE) SHEATHING COMPOUND
BS 7835:1996 Specification for cables with extruded cross-linked polyethylene or ethylene propylene rubber insulation for rated voltages from 3800/6600 V up to 19000/33000 V having low emission of smoke and corrosive gases when affected by fire
BS EN 10002-1:2001 Tensile testing of metallic materials Method of test at ambient temperature

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.