BS 5839-1(2002) : 2002
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR SYSTEM DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE
Hardcopy , PDF
03-31-2013
English
01-01-2008
Committees responsible
Foreword
Section 1. General
1 Scope
2 Normative references
3 Terms and definitions
4 Need for a fire alarm system
5 Categories of system
6 Exchange of information and definition of responsibilities
7 Variations from the recommendations of this standard
Section 2. Design considerations
8 Relationship between system Category and areas protected
9 Actuation of other fire protection systems or safety
facilities
10 Systems in explosive gas or dust atmospheres
11 System components
12 Monitoring, integrity and reliability of circuits external
to control equipment
13 Detection zones
14 Alarm zones
15 Communication with the fire service
16 Audible alarm signals
17 Visual alarm signals
18 Fire alarm warnings for people with impaired hearing
19 Staged fire alarms
20 Manual call points
21 Types of fire detector and their selection
22 Spacing and siting of automatic fire detectors
23 Control and indicating equipment
24 Networked systems
25 Power supplies
26 Cables, wiring and other interconnections
27 Radio-linked systems
28 Electromagnetic compatibility
29 Electrical safety
Section 3. Limitation of false alarms
30 Responsibility for limitation of false alarms
31 Categories of false alarms
32 Acceptable rate of false alarms
33 Causes of false alarms
34 Design process for limitation of false alarms
35 Measures to limit false alarms
Section 4. Installation
36 Responsibility of installer
37 Installation practices and workmanship
38 Inspection and testing of wiring
Section 5. Commissioning and handover
39 Commissioning
40 Documentation
41 Certification
42 Acceptance
43 Verification
Section 6. Maintenance
44 Routine testing
45 Inspection and servicing
46 Non-routine attention
Section 7. Users responsibilities
47 Responsible person
48 Log book
Annex A (informative) - Choice of appropriate category of fire
detection and alarm system
Annex B (informative) - Typical noise levels in buildings
Annex C (normative) - Control and transmission equipment for
tactile alarm devices provided for people
with impaired hearing systems
Annex D (normative) - Method for calculating standby battery
capacity
Annex E (informative) - Schematic for design against false alarms
Annex F (informative) - Model format for system log book
Annex G (informative) Model certificates
Bibliography
Gives recommendations for the planning, design, installation, commissioning and maintenance of fire detection and fire alarm systems in and around buildings, other than dwelling.
Committee |
FSH/12/1
|
DevelopmentNote |
Supersedes 01/540647 DC and BS 5839-1(1988) Also available as part of BS KIT 115. (11/2002) 2002 Edition Re-Issued in March 2008 & incorporates AMD 2 2008. Supersedes 07/30171700 DC. (04/2008)
|
DocumentType |
Standard
|
Pages |
146
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
BS 4678-4:1982 | Cable trunking Specification for cable trunking made of insulating material |
DD CLC/TS 50398:2009 | Alarm systems. Combined and integrated systems. General requirements |
IEC 60702-1:2002+AMD1:2015 CSV | Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 1: Cables |
BS EN 50131-1 : 2006 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS |
BS ISO 7240-15:2014 | Fire detection and alarm systems Point-type fire detectors using smoke and heat sensors |
BS EN 60651:1994 | Specification for sound level meters |
BS EN 54-7:2001 | Fire detection and fire alarm systems Smoke detectors. Point detectors using scattered light, transmitted light or ionization |
BS EN 50200:2015 | Method of test for resistance to fire of unprotected small cables for use in emergency circuits |
BS EN ISO 13943:2017 | Fire safety. Vocabulary |
BS EN 60702-2 : 2002 | MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 2: TERMINATIONS |
BS EN 54-4:1998 | Fire detection and fire alarm systems Power supply equipment |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS EN 54-2 : 1998 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT |
BS EN 54-3:2014 | Fire detection and fire alarm systems Fire alarm devices. Sounders |
BS EN 60079-14:2014 | Explosive atmospheres Electrical installations design, selection and erection |
BS 8434-2(2003) : 2003 | METHODS OF TEST FOR ASSESSMENT OF THE FIRE INTEGRITY OF ELECTRIC CABLES - PART 2: TEST FOR UNPROTECTED SMALL CABLES FOR USE IN EMERGENCY CIRCUITS - BS EN 50200 WITH A 930 DEGREE C FLAME AND WITH WATER SPRAY |
BS EN 54-12:2015 | Fire detection and fire alarm systems Smoke detectors. Line detectors using an optical beam |
BS 5839-8:1998 | Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning, and maintenance of voice alarm systems |
PD 7974-4:2003 | Application of fire safety engineering principles to the design of buildings Detection of fire and activation of fire protection systems. (Sub-system 4) |
BS 8434-1:2003 | Methods of test for assessment of the fire integrity of electric cables Test for unprotected small cables for use in emergency circuits. BS EN 50200 with addition of water spray |
BS EN 54-10:2002 | Fire detection and fire alarm systems Flame detectors. Point detectors |
BS EN 50281-1-2:1999 | Electrical apparatus for use in the presence of combustible dust. Electrical apparatus protected by enclosures Selection, installation and maintenance |
BS 5839-6:2004 | Fire detection and fire alarm systems for buildings Code of practice for the design, installation and maintenance of fire detection and fire alarm systems in dwellings |
BS 7974:2001 | Application of fire safety engineering principles to the design of buildings. Code of practice |
BS EN 60702-1 : 2002 | MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES |
BS ISO 7240-8:2014 | Fire detection and alarm systems Point-type fire detectors using a carbon monoxide sensor in combination with a heat sensor |
BS EN 54-25:2008 | Fire detection and fire alarm systems Components using radio links |
BS EN 54-20:2006 | Fire detection and fire alarm systems Aspirating smoke detectors |
BS EN 54-11:2001 | Fire detection and fire alarm systems Manual call points |
BS 5839-9:2003 | Fire detection and alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of emergency voice communication systems |
IEC 60702-2:2002+AMD1:2015 CSV | Mineral insulated cables and their terminations with a rated voltagenot exceeding 750 V - Part 2: Terminations |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.